This European Standard specifies requirements for factory made, self-supporting, double skin metal faced insulating sandwich panels, which are intended for discontinuous laying in the following applications:
a)   roofs and roof cladding;
b)   external walls and wall cladding;
c)   walls (including partitions) and ceilings within the building envelope.
The insulating core materials covered by this European Standard are rigid polyurethane, expanded polystyrene, extruded polystyrene foam, phenolic foam, cellular glass and mineral wool.
NOTE   Polyurethane (PUR) includes polyisocyanurate (PIR).
Panels with edge details that utilise different materials from the main insulating core are included in this European Standard.
Panels used in cold store applications are included in this European Standard. Panels, put on the market as a component of a cold storage room, building and/or building envelope kit are covered by ETA-Guideline 021 “Cold storage premises kits”.
This European Standard does not cover the following:
i.   sandwich panels with a declared thermal conductivity for the insulating core greater than 0,06 W/m•K at 10 °C;
ii.   products consisting of two or more clearly defined layers of different insulating core materials (multi-layered);
iii.   panels with perforated facing(s);
iv.   curved panels.

  • Standard
    175 pages
    English language
    e-Library read for
    1 day

This document specifies test methods needed for determination of mechanical strength, building physical behaviour and durability of factory-made double skin metal faced insulating sandwich panels (hereafter sandwich panels) for both self-supporting and structural applications in roofs, in external and internal walls (including partitions) and in ceilings in buildings as well as those in cold store applications.

  • Draft
    120 pages
    English language
    e-Library read for
    1 day

This document specifies design methods for combination of actions and spans for factory made double skin metal faced insulating sandwich panels (hereafter sandwich panels). The sandwich panels are for use in self-supporting and structural applications in roofs, in external and internal walls (including partitions) and in ceilings in buildings as well as those in cold store applications.
This document covers uniformly distributed loads, line loads perpendicular to the span over the full width of the panel and thermal gradients, it gives no information about normal forced axially loaded sandwich panels, torsional loaded sandwich panels or sandwich panels as a part of a diaphragm.

  • Draft
    44 pages
    English language
    e-Library read for
    1 day

This document specifies test methods for determination of characteristics for fixing of factory-made double skin metal faced insulating sandwich panels (hereafter referred to as sandwich panels) to substructure and for stabilization of substructure. Sandwich panels are used for both self-supporting and structural applications in roofs, in external and internal walls (including partitions) and in ceilings in buildings as well as those in cold store applications.

  • Draft
    39 pages
    English language
    e-Library read for
    1 day

This document specifies characteristics of factory-made double skin metal faced insulating sandwich panels intended to be used as elements for self-supporting applications in construction works in roofs, external and internal walls (including partitions) and in ceilings (hereafter referred to as non-structural sandwich panels).
The non-structural sandwich panels consist of two faces made of:
—   steel;
—   stainless steel;
—   aluminium;
—   aluminium alloys;
—   copper
and insulating core made of:
—   rigid polyurethane (PU) (see 3.1.17);
—   expanded polystyrene (EPS) (see 3.1.15);
—   extruded polystyrene foam (XPS) (see 3.1.16);
—   phenolic foam (PF) (see 3.1.14);
—   mineral wool (MW) (see 3.1.13)
either by using an auto-adhesive bonding technique or by using a separate adhesive layer.
Products which are
—   curved;
—   perforated (perforated faces);
—   used for stabilization purposes;
—   consisting of two or more clearly specified layers of different insulating core materials (multi-layered) or of different materials per face;
—   used as ceilings when fastening is under permanent tension load;
—   parts of clean room kits, conditioning room kits, cold storage room kits and cold storage building envelope and building kits;
—   reused;
are excluded from this product definition.
Products intended to be used for structural applications are excluded from this product definition.

  • Draft
    81 pages
    English language
    e-Library read for
    1 day

This document covers structural double skin metal faced insulating sandwich panels intended to be used as elements for structural applications in construction works in roofs, in external and internal walls (including partitions) and in ceilings (hereafter referred to as structural sandwich panels).
The structural sandwich panels consist of two faces made of:
—   steel;
—   stainless steel;
—   aluminium;
—   aluminium alloys;
—   copper
and insulating core made of
—   rigid polyurethane foam (PU) (see 3.1.23);
—   expanded polystyrene (EPS) (see 3.1.21);
—   extruded polystyrene foam (XPS) (see 3.1.22);
—   phenolic foam (PF) (see 3.1.20);
—   mineral wool (MW) (see 3.1.19)
either by using an auto-adhesive bonding technique or by using a separate adhesive layer.
Products which are
—   curved;
—   perforated (perforated face);
—   used for stabilization purposes having insulation core material of phenolic foam;
—   consisting of two or more clearly specified layers of different insulating core materials (multi-layered) or of different materials per face;
—   used as ceilings when fastening is under permanent tension load;
—   parts of clean room kits, conditioning room kits, cold storage room kits and cold storage building envelope and building kits;
—   reused
are excluded from this product definition.

  • Draft
    93 pages
    English language
    e-Library read for
    1 day

This document provides product category rules (c-PCR), that are complementary to EN 15804:2012+A2:2019, for Type III environmental declarations for sandwich panels within the scope of prEN 14509-1:2025 and prEN 14509-2:2025, which are used for non-structural and structural purposes in building envelopes and for sandwich panels with perforated faces and for sandwich panels with core materials others than defined in prEN 14509-1:2025 and prEN 14509-2:2025.
Manufactured on industrial plant, double skin metal faced insulating sandwich panels are designed to be laid with overlapping edges in the following applications:
- roofs and discontinuous roofing;
- outer walls and wall cladding;
- walls (incl. partition walls) and (suspended) ceilings inside the building envelope.
This document is intended to be used cradle-to-grave, declaring modules A1-A3, modules C1-C4 and module D, according to EN 15804:2012+A2:2019
NOTE The assessment of social and economic performances at product level is not covered by this document.

  • Draft
    32 pages
    English language
    e-Library read for
    1 day

This document establishes requirements for factory-made structural double skin metal faced insulating panels, intended for installation as elements with interlocking or overlapping longitudinal joints in the following applications:
a)   roofs (also for refurbishment);
b)   external walls and wall cladding (e.g. on brick walls for refurbishment or sandwich panels on liner trays);
c)   walls (including partitions) and ceilings within the building envelope.
It is essential that structural double skin metal faced insulating sandwich panels according to this document (FprEN 14509-2) fulfil the requirements of EN 14509.
This document (FprEN 14509-2) gives the basic rule for use of structural sandwich panels for structural applications including fixing of panels. The clarification of which application is structural needs to be given by national provisions. The stabilization parameters needed to contribute to stabilization of individual structural elements (supporting structure) as defined as structural class II according to EN 1993-1-3 are included.
The insulating core materials covered by this document are rigid polyurethane, expanded polystyrene, extruded polystyrene foam, phenolic foam, cellular glass and mineral wool. For the stabilization purposes only, the following insulation core materials are covered rigid polyurethane, mineral wool, extruded polystyrene foam and expanded polystyrene foam.
NOTE   Polyurethane (PUR) includes polyisocyanurate (PIR).
Due to durability performance reasons, only coated face material of steel faces is used (both organic and metallic coating). Uncoated steel is not used as steel face material. Uncoated stainless steel, aluminium and copper can be used in visible faces of sandwich panels.
Panels with edge details that utilize different materials from the main insulating core are included in this document if there is no influence on mechanical performance of the panel.
Panels used in cold store applications are included in this document. Panels, put on the market as a component of a cold storage room, building and/or building envelope kit are excluded.
This document does not cover the following:
-   sandwich panels with a declared thermal conductivity for the insulating core greater than defined in the relevant harmonized European Standards for insulation materials;
-   products consisting of two or more clearly defined layers of different insulating core materials (multi-layered);
-   curved panels;
-   perforated panels;
-   fixings under permanent tension load for ceilings;
-   special type of fastening such as ‘T’ support for ceiling, threaded rods with clamps for wall, omega and clamps for wall and ceiling, injected joint with flashing and threaded rods for wall and ceiling;
-   fasteners.

  • Draft
    33 pages
    English language
    e-Library read for
    1 day

This European Standard specifies test methods needed for determination of characteristics for fixing of
factory-made double skin metal faced insulating sandwich panels (hereafter sandwich panels) to substructure and for stabilization of substructure. The sandwich panels are for use in elements for both self-supporting and structural applications in roofs, in external and internal walls (including partitions) and in ceilings in buildings as well as those in cold store applications.
NOTE The description of self-supporting sandwich panels is given in prEN 14509-1 and for structural
sandwich panels in FprEN 14509-2.

  • Draft
    37 pages
    English language
    e-Library read for
    1 day

This document specifies test methods needed for determination of mechanical strength, building physical behaviour and durability of factory-made double skin metal faced insulating sandwich panels (hereafter sandwich panels) for use in elements for both self-supporting and structural applications in roofs, in external and internal walls (including partitions) and in ceilings in buildings as well as those in cold store applications.

  • Draft
    112 pages
    English language
    e-Library read for
    1 day

This document specifies design methods for combination of actions and spans for factory made double skin metal faced insulating sandwich panels (hereafter sandwich panels). The sandwich panels are for use in elements for both self-supporting and structural applications in roofs, in external and internal walls (including partitions) and in ceilings in buildings as well as those in cold store applications.
NOTE   The description of self-supporting sandwich panels is given in prEN 14509-1:2020, Clause 1 and for structural sandwich panels in prEN 14509-2:2020, Clause 1.

  • Draft
    30 pages
    English language
    e-Library read for
    1 day

This European Standard specifies requirements for factory made, self-supporting, double skin metal faced insulating sandwich panels, which are intended for discontinuous laying in the following applications:
a)   roofs and roof cladding;
b)   external walls and wall cladding;
c)   walls (including partitions) and ceilings within the building envelope.
The insulating core materials covered by this European Standard are rigid polyurethane, expanded polystyrene, extruded polystyrene foam, phenolic foam, cellular glass and mineral wool.
NOTE   Polyurethane (PUR) includes polyisocyanurate (PIR).
Panels with edge details that utilise different materials from the main insulating core are included in this European Standard.
Panels used in cold store applications are included in this European Standard. Panels, put on the market as a component of a cold storage room, building and/or building envelope kit are covered by ETA-Guideline 021 “Cold storage premises kits”.
This European Standard does not cover the following:
i.   sandwich panels with a declared thermal conductivity for the insulating core greater than 0,06 W/m•K at 10 °C;
ii.   products consisting of two or more clearly defined layers of different insulating core materials (multi-layered);
iii.   panels with perforated facing(s);
iv.   curved panels.

  • Draft
    41 pages
    English language
    e-Library read for
    1 day

This document establishes requirements for factory-made structural double skin metal faced insulating panels, intended for installation as elements with interlocking or overlapping longitudinal joints in the following applications:
a)   roofs (also for refurbishment);
b)   external walls and wall cladding (e.g. on brick walls for refurbishment or sandwich panels on liner trays);
c)   walls (including partitions) and ceilings within the building envelope.
It is essential that structural double skin metal faced insulating sandwich panels according to this document (FprEN 14509-2) fulfil the requirements of EN 14509.
This document (FprEN 14509-2) gives the basic rule for use of structural sandwich panels for structural applications including fixing of panels. The clarification of which application is structural needs to be given by national provisions. The stabilization parameters needed to contribute to stabilization of individual structural elements (supporting structure) as defined as structural class II according to EN 1993-1-3 are included.
The insulating core materials covered by this document are rigid polyurethane, expanded polystyrene, extruded polystyrene foam, phenolic foam, cellular glass and mineral wool. For the stabilization purposes only, the following insulation core materials are covered rigid polyurethane, mineral wool, extruded polystyrene foam and expanded polystyrene foam.
NOTE   Polyurethane (PUR) includes polyisocyanurate (PIR).
Due to durability performance reasons, only coated face material of steel faces is used (both organic and metallic coating). Uncoated steel is not used as steel face material. Uncoated stainless steel, aluminium and copper can be used in visible faces of sandwich panels.
Panels with edge details that utilize different materials from the main insulating core are included in this document if there is no influence on mechanical performance of the panel.
Panels used in cold store applications are included in this document. Panels, put on the market as a component of a cold storage room, building and/or building envelope kit are excluded.
This document does not cover the following:
-   sandwich panels with a declared thermal conductivity for the insulating core greater than defined in the relevant harmonized European Standards for insulation materials;
-   products consisting of two or more clearly defined layers of different insulating core materials (multi-layered);
-   curved panels;
-   perforated panels;
-   fixings under permanent tension load for ceilings;
-   special type of fastening such as ‘T’ support for ceiling, threaded rods with clamps for wall, omega and clamps for wall and ceiling, injected joint with flashing and threaded rods for wall and ceiling;
-   fasteners.

  • Draft
    70 pages
    English language
    e-Library read for
    1 day

This European Standard specifies requirements for factory made, self-supporting, double skin metal faced insulating sandwich panels, which are intended for discontinuous laying in the following applications:
a)   roofs and roof cladding;
b)   external walls and wall cladding;
c)   walls (including partitions) and ceilings within the building envelope.
The insulating core materials covered by this European Standard are rigid polyurethane, expanded polystyrene, extruded polystyrene foam, phenolic foam, cellular glass and mineral wool.
NOTE   Polyurethane (PUR) includes polyisocyanurate (PIR).
Panels with edge details that utilise different materials from the main insulating core are included in this European Standard.
Panels used in cold store applications are included in this European Standard. Panels, put on the market as a component of a cold storage room, building and/or building envelope kit are covered by ETA-Guideline 021 “Cold storage premises kits”.
This European Standard does not cover the following:
i.   sandwich panels with a declared thermal conductivity for the insulating core greater than 0,06 W/m•K at 10 °C;
ii.   products consisting of two or more clearly defined layers of different insulating core materials (multi-layered);
iii.   panels with perforated facing(s);
iv.   curved panels.

  • Draft
    160 pages
    English language
    e-Library read for
    1 day

2008-11-13 SJ: Corrigendum allowing the citation of the main standard in the OJEU.
EC - Addition of NOTE in 5.2.4.2 for the above mentioned reason

  • Corrigendum
    2 pages
    English language
    e-Library read for
    1 day

This European Standard specifies requirements for factory made, self-supporting, double skin metal faced insulating sandwich panels, which are intended for discontinuous laying in the following applications:
a)   roofs and roof cladding;
b)   external walls and wall cladding;
c)   walls (including partitions) and ceilings within the building envelope.
The insulating core materials covered by this European Standard are rigid polyurethane, expanded polystyrene, extruded polystyrene foam, phenolic foam, cellular glass and mineral wool.
NOTE   Polyurethane (PUR) includes polyisocyanurate (PIR).
Panels with edge details that utilize different materials from the main insulating core are included in this European Standard.
Panels used in cold store applications are included in this European Standard. Panels, put on the market as a component of a cold storage room, building and/or building envelope kit, will be covered by a future ETA-Guideline “Cold storage premises kits”.
This European Standard does not cover the following:
i.   sandwich panels with a declared thermal conductivity for the insulating core greater than 0,06 W/m×K at
10 °C;
ii.   products consisting of two or more clearly defined layers of different insulating core materials (multi-layered);
iii.   panels with perforated facing(s);
iv.   curved panels.

  • Standard
    147 pages
    English language
    e-Library read for
    1 day

Frequently Asked Questions

CEN/TC 128/SC 11 is a Subcommittee within the European Committee for Standardization (CEN). It is named "Double skin metal faced insulating sandwich panels for roofing and cladding" and is responsible for: Standardisation of factory made self-supporting double skin metal faced sandwich panels having an insulated core bonded to both facings. This committee has published 16 standards.

CEN/TC 128/SC 11 develops CEN standards. The scope of work includes: Standardisation of factory made self-supporting double skin metal faced sandwich panels having an insulated core bonded to both facings. Currently, there are 16 published standards from this subcommittee.

The European Committee for Standardization (CEN) is a public standards organization that brings together the national standardization bodies of 34 European countries. CEN provides a platform for developing European Standards (ENs) and other technical documents in relation to various products, materials, services, and processes, supporting the European Single Market.

A Subcommittee (SC) in CEN operates under a Technical Committee and focuses on a specific subset of the TC's scope. Subcommittees develop standards and technical specifications in their specialized area, reporting to their parent Technical Committee. They may also have working groups for detailed technical work.