Multi-firing sauna stoves fired by natural wood logs - Requirements and test methods

This European Standard covers multi-firing sauna stoves in which the heating stones are separated from and indirectly heated by the fire and the flue gases and which may be re-fuelled with several fuel loads.
This European Standard specifies requirements relating to the design, manufacture, construction, safety and performance (efficiency and emission) of multi-firing sauna stoves fired by wood logs and provides instructions for them. Furthermore, it also gives provisions for evaluation of conformity (i.e. initial type testing (ITT) and factory production control (FPC) and marking of these products.
This standard is applicable to hand-fuelled intermittent burning multi-firing sauna stoves, which provide heat into the space where they are installed.
These multi-firing sauna stoves may be supplied either as an assembled appliance or as a manufacturer’s pre-designed unit consisting of pre-fabricated components designed to be built on site in accordance with the manufacturer’s specified assembly instructions. One-off installations are not included.
These multi-firing sauna stoves may burn only natural wood logs in accordance with the appliance operating instructions.
Single-firing heat storage sauna stoves, in which the stones are directly heated by the fire and the flue gases, which pass through them, are not covered by this European Standard. This standard is also not applicable to mechanically fed sauna stoves, sauna stoves having fan assisted combustion air, sauna stoves fitted with a boiler, sauna stoves with incorporated flue or sauna stoves having any electrical connection.

Mehrfach befeuerbare Saunaöfen zur Verfeuerung von naturbelassenem Scheitholz - Anforderungen und Prüfverfahren

Dieses Dokument ist anwendbar für mehrfach befeuerbare Saunaöfen (bei denen das Erhitzen der Steine getrennt von Feuer und Rauchgasen erfolgt und indirekt durch diese erhitzt wird und die mit mehreren Brennstoffladungen nachgefüllt werden dürfen) zur Verfeuerung von naturbelassenem Scheitholz
Der Verwendungszweck der Geräte ist Raumheizung in Wohngebäuden. Der beheizte Raum ist ein Saunaraum, der für kurze Zeit auf eine höhere Temperatur als die normale Raumtemperatur für Wellness- und Badezwecke aufgeheizt wird.
Diese Mehrfach-Saunaöfen können entweder als montiertes Gerät oder als vorgefertigte Einheit des Herstellers geliefert werden, die aus vorgefertigten Bauteilen besteht, die vor Ort nach der vom Hersteller angegebenen Montageanleitung zusammengebaut werden.
Die Geräte können wie angegeben folgende feste Brennstoffe verfeuern:
   Scheitholz;
Dieses Dokument ist nicht anzuwenden für
   mechanisch beschickte Geräte;
   Geräte mit Verbrennungsluftgebläse;
   einfach befeuerbare Speichersaunaöfen, in denen die Steine direkt durch das Feuer und die durch sie hindurchströmende Abgase beheizt werden
   einmalige Installationen.
   Geräte mit wasserführenden Teilen oder mit einem Wasseranschluss.
Dieses Dokument legt das Verfahren für die Bewertung und Überprüfung der Leistungsbeständigkeit (AVCP, en: assessment and verification of constancy of performance) der Eigenschaften mehrfach befeuerbarer Saunaöfen fest.

Appareils de chauffage domestiques à combustion solide - Partie 2-10 : Poêles de sauna à allumage multiple à bûches de bois naturelles.

Le présent document s'applique aux poêles de sauna à allumage multiple à bûches de bois naturelles (dans lesquels les pierres chauffantes sont isolées des flammes et des fumées par lesquelles elles sont indirectement chauffées, et qui sont susceptibles d'être rechargés avec plusieurs charges de combustible).
L'usage prévu des appareils est le chauffage domestique dans les bâtiments résidentiels. L'espace chauffé est un sauna qui est chauffé à une température ambiante supérieure à la normale pour favoriser le bien-être des occupants du bain, sur une courte durée.
Ces poêles de sauna à allumage multiple peuvent être fournis sous la forme d'un appareil assemblé ou d'une unité conçue au préalable par le fabricant, constituée d'éléments préfabriqués, destinés à être montés sur le site conformément aux instructions d'assemblage spécifiées par le fabricant.
Ces appareils peuvent brûler les combustibles solides suivants, comme spécifié :
— bûches de bois.
Le présent document ne s'applique pas :
— aux appareils à alimentation mécanique ;
— aux appareils dont l'air de combustion est pulsé par un ventilateur ;
— aux poêles de sauna à accumulation de chaleur et allumage unique, dans lesquels les pierres sont directement chauffées par les flammes et les fumées qui les traversent ;
— aux installations provisoires ;
— aux appareils équipés d'un bouilleur ou raccordés à un système à eau.
Le présent document spécifie les procédures d'évaluation et de vérification de la constance des performances (EVCP) des caractéristiques des poêles de sauna à allumage multiple.

Večnamenske peči za savno na polena iz naravnega lesa - Zahteve in preskusne metode

Ta evropski standard zajema večnamenske peči za savno, pri katerih so grelni kamni ločeni od ognja in dimnih plinov ter se z njimi posredno segrevajo, in ki jih je mogoče ponovno napolniti z več polnitvami goriva. Ta evropski standard določa zahteve v zvezi z načrtovanjem, izdelavo, sestavo, varnostjo in zmogljivostjo (učinkovitostjo in emisijami) večnamenskih peči za savno na polena iz lesa ter podaja navodila zanje. Poleg tega podaja določbe za vrednotenje skladnosti, tj. začetni tipski preskus (ITT), ter kontrolo proizvodnje v obratu (FPC) in označevanje teh izdelkov. Ta standard se uporablja za večnamenske peči za savno z ročnim polnjenjem za občasno ogrevanje, ki zagotavljajo toploto v prostoru, kjer so nameščene. Te večnamenske peči za savno so lahko dobavljene kot sestavljena naprava ali kot proizvajalčeva vnaprej zasnovana enota, sestavljena iz montažnih komponent, namenjenih za vgradnjo na mestu uporabe v skladu s proizvajalčevimi navodili za sestavljanje. Enkratne vgradnje niso vključene. V teh večnamenskih pečeh za savno je mogoče kuriti samo polena iz naravnega lesa v skladu z navodili za uporabo naprave.  Peči za savno z enkratnim kurjenjem in funkcijo za shranjevanje toplote, v katerih se kamni neposredno segrevajo z ognjem in dimnimi plini, ki prehajajo skoznje, niso zajete v tem evropskem standardu. Ta standard se prav tako ne uporablja za peči za savno z mehanskim dodajanjem, peči za savno, ki delujejo z zrakom za zgorevanje s pomočjo ventilatorja, peči za savno, opremljene s kotlom, peči za savno z vgrajenim dimnikom ali peči za savno s kakršnim koli električnim priključkom.

General Information

Status
Published
Public Enquiry End Date
31-Mar-2025
Publication Date
09-Jun-2025
Technical Committee
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
04-Jun-2025
Due Date
09-Aug-2025
Completion Date
10-Jun-2025

Relations

Standard
SIST EN 16510-2-10:2025
English language
41 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


SLOVENSKI STANDARD
01-julij-2025
Nadomešča:
SIST EN 15821:2011
Večnamenske peči za savno na polena iz naravnega lesa - Zahteve in preskusne
metode
Multi-firing sauna stoves fired by natural wood logs - Requirements and test methods
Mehrfach befeuerbare Saunaöfen zur Verfeuerung von naturbelassenem Scheitholz -
Anforderungen und Prüfverfahren
Appareils de chauffage domestiques à combustion solide - Partie 2-10 : Poêles de sauna
à allumage multiple à bûches de bois naturelles.
Ta slovenski standard je istoveten z: EN 16510-2-10:2025
ICS:
97.100.30 Grelniki na trdo gorivo Solid fuel heaters
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

EN 16510-2-10
EUROPEAN STANDARD
NORME EUROPÉENNE
May 2025
EUROPÄISCHE NORM
ICS 97.100.30 Supersedes EN 15821:2010
English Version
Multi-firing sauna stoves fired by natural wood logs -
Requirements and test methods
Appareils de chauffage domestiques à combustion Mehrfach befeuerbare Saunaöfen zur Verfeuerung von
solide - Partie 2-10 : Poêles de sauna à allumage naturbelassenem Scheitholz - Anforderungen und
multiple à bûches de bois naturelles. Prüfverfahren
This European Standard was approved by CEN on 11 May 2025.

CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this
European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references
concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN
member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by
translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management
Centre has the same status as the official versions.

CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway,
Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Türkiye and
United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION

EUROPÄISCHES KOMITEE FÜR NORMUNG

CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2025 CEN All rights of exploitation in any form and by any means reserved Ref. No. EN 16510-2-10:2025 E
worldwide for CEN national Members.

Contents Page
European foreword . 5
1 Scope . 7
2 Normative references . 7
3 Terms and definitions . 7
4 Characteristics . 8
4.1 Load bearing capacity . 8
4.2 Protection of combustible materials . 8
4.3 Carbon monoxide emission (CO) . 9
4.4 Nitrogen oxides (NO ) emissions . 9
x
4.5 Emission of organic gaseous compounds (OGC) . 10
4.6 Particulate matter (PM) emissions . 10
4.7 Safety and accessibility in use . 10
4.7.1 General . 10
4.7.2 Flue gas outlet temperature at nominal heat output . 10
4.7.3 Minimum flue draught at nominal heat output . 10
4.7.4 Flue gas mass flow at nominal heat output . 11
4.7.5 Fire safety of installation to the chimney . 11
4.8 Energy economy and heat retention . 11
4.8.1 Space heat output at nominal heat output . 11
4.8.2 Water heat output, if existing at nominal heat output. 11
4.8.3 Efficiency at nominal heat output . 11
4.8.4 Electric power consumption at nominal heat output, if existing . 11
4.8.5 Standby mode power consumption, if existing . 12
4.9 Environmental sustainability . 12
5 Descriptive features . 13
5.1 Data for potential use with room ventilation systems: type of appliance (in relation
to its tightness to the room) . 13
5.2 Data for the building's statics: appliance's mass . 13
5.3 Materials and construction elements . 14
5.3.1 General . 14
5.3.2 General stresses . 14
5.3.3 Integral boiler or heat exchanger . 14
5.4 Risk of burning fuel falling out . 14
5.5 Temperature rise in the fuel storage . 14
5.6 Temperature rise of the operating components . 14
5.7 Spillage of flue gases into the room . 14
5.7.1 Possible spillage of CO, if relevant for the fuel type. 14
5.7.2 Open operation . 15
5.8 Cleanability . 15
5.8.1 Heating surfaces . 15
5.8.2 Flueways . 15
5.8.3 Ashpan . 15
5.8.4 Bottomgrate . 15
5.8.5 Damper . 15
5.8.6 Fan-cut-out-device . 15
5.9 Strength and leak tightness of boiler shells . 15
6 Assessment and verification of constancy of performance - AVCP . 15
6.1 General . 15
6.2 Assessment of performance . 16
6.2.1 General . 16
6.2.2 Test samples, testing and compliance criteria . 16
6.3 Verification of constancy of performance . 17
6.3.1 Factory production control (FPC) . 17
6.3.2 Initial inspection of factory to validate environmental sustainability company
specific data . 21
6.3.3 Environmental sustainability assessment validation . 22
Annex A (normative) Test methods . 23
A.1 Test environment . 23
A.1.1 Ambient room temperature . 23
A.1.1001 Sauna test room internal temperature . 23
A.2 Test assembly . 23
A.2.1 General . 23
A.2.3 Measurement section . 25
A.2.3.5 Safety distance to the appliance’s front measurement . 25
A.2.1001 Sauna test room . 26
A.3 Measurement equipment. 28
A.4 Test procedures . 28
A.4.1 Appliance installation . 28
A.4.1.3 Appliance installation procedure . 28
A.4.2 Fuel load and basic firebed . 29
A.4.2.1001 Calculation of batch charges of test load . 29
A.4.4 Flue gas losses . 29
A.4.4.2 Composition of the flue gas . 29
A.4.7 Performance test at nominal heat output . 29
A.4.7.1 General . 29
A.4.7.3 Test period . 30
A.4.10 Safety tests . 32
A.4.10.4 Temperature safety tests . 32
A.4.10.4.2 Temperature safety test for woodburning and multifuel appliances . 32
A.4.10.4.2.1 General . 32
A.4.10.4.2.2 Ignition and test period . 32
A.4.11 Safety tests of roomsealed appliances . 33
A.5 Test results . 33
A.6 Calculation methods . 33
A.6.2 Formulae . 33
A.6.2.1 Heat losses and efficiency . 34
A.6.2.4 Space heat output . 34
A.7 Test report . 34
Annex ZA (informative) Relationship of this European Standard with Regulation (EU) No.
305/2011 . 35
ZA.1 Scope and relevant characteristics . 35
ZA.2 System of Assessment and Verification of Constancy of Performance (AVCP) . 39
ZA.3 Assignment of AVCP tasks . 40

European foreword
This document (EN 16510-2-10:2025) has been prepared by Technical Committee CEN/TC 295
“Residential solid fuel burning appliances”, the secretariat of which is held by BSI.
This European Standard shall be given the status of a national standard, either by publication of an
identical text or by endorsement, at the latest by November 2025, and conflicting national standards shall
be withdrawn at the latest by November 2025.
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CEN-CENELEC shall not be held responsible for identifying any or all such patent rights.
This document supersedes EN 15821:2010 as amended and corrected.
— measurement methods for NO , hydrocarbon and particulate matter emissions for solid fuel burning
x
appliances;
— specifications for classification of solid fuel burning appliances and system boundaries for room
sealed appliances;
— Annex ZA updated according to requirements of M/577 and its amendments;
— Assessment and verification of constancy of performance – AVCP 3+ added;
— requirements for environmental sustainability added.
This document has been prepared under a standardization request given to CEN by the European
Commission. The Standing Committee of the EFTA States subsequently approves these requests for its
Member States.
For relationship with (EU) Regulation 305/2011, see informative Annex ZA, which is an integral part of
this document.
The structure of EN 16510, Residential solid fuel burning appliances, is as follows:
— Part 1: General requirements and test methods;
— Part 2-1: Roomheaters;
— Part 2-2: Inset appliances including open fires;
— Part 2-3: Cookers;
— Part 2-4: Independent boilers — Nominal heat output up to 50 kW;
— Part 2-5: Slow heat release appliances;
— Part 2-6: Mechanically by wood pellets fed roomheaters, inset appliances and cookers;
— Part 2-7: Combination appliances fired by wood logs and pellets;
— Part 2-10: Multi-firing sauna stoves fired by natural wood logs.
Other sections of Part 2 will be added to cover residential solid fuel burning appliances not included in
parts 2-1 to 2-7 and in 2-10.
Subclauses and Figures which are additional to those in EN 16510-1:2022 are numbered starting with
1001. Annexes which are additional to those in EN 16510-1:2022 are numbered starting with JA.
Any feedback and questions on this document should be directed to the users’ national standards
body/national committee. A complete listing of these bodies can be found on the CEN and CENELEC
websites.
According to the CEN-CENELEC Internal Regulations, the national standards organisations of the
following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia,
Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland,
Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Republic of North
Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Türkiye and the United
Kingdom.
1 Scope
This document is applicable to multi-firing sauna stoves for natural wood logs (in which the heating of
stones are separated from and indirectly heated by the fire and the flue gases and which may be re-fuelled
with several fuel loads).
The intended use of the appliances is space heating in residential buildings. The space heated is sauna
room which is heated higher-than-normal room temperature for wellbeing and bathing purposes, for
short period of time.
These multi-firing sauna stoves may be supplied either as an assembled appliance or as a manufacturer’s
pre-designed unit consisting of prefabricated components designed to be built on site in accordance with
the manufacturer’s specified assembly instructions.
These appliances can burn the following solid fuels as specified:
— wood logs;
This document is not applicable to:
— appliances that are mechanically fed;
— appliances with fan assisted combustion air;
— single-firing heat storage sauna stoves, in which the stones are directly heated by the fire and the flue
gases, which pass through them;
— one off installations;
— appliances incorporating a boiler or connected to a water system.
This document specifies procedures for assessment and verification of constancy of performance (AVCP)
of characteristics of multi firing sauna stoves.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content
constitutes requirements of this document.
EN 15804:2012+A2:2019, Sustainability of construction works - Environmental product declarations - Core
rules for the product category of construction products
EN 16510-1:2022, Residential solid fuel burning appliances - Part 1: General requirements and test methods
EN 16510-2-4:2022, Residential solid fuel burning appliances - Part 2-4: Independent boilers - Nominal heat
output up to 50 kW
3 Terms and definitions
For the purposes of this document, the terms and definitions given in EN 16510-1:2022 and the following
apply.
ISO and IEC maintain terminology databases for use in standardization at the following addresses:
• ISO Online browsing platform: available at https://www.iso.org/obp
• IEC Electropedia: available at https://www.electropedia.org/
3.14
EN 16510-1:2022 definition 3.14 is replaced in this document with following:

batch charge
proportion of the test load as declared in the operating manual that can be added at specified intervals
during the test period of the performance test at nominal heat output

3.1001
sauna stove
stove that has a fully enclosed firebox with a firedoor which is normally closed, that distributes heat by
radiation and/or convection and is also fitted with stones or other heat retaining material onto which
water is poured to produce hot steam/vapour that rises from the hot sauna stones, and that may also
provide hot water for washing when fitted with an optional open water vessel
3.1002
multi-firing sauna stove
sauna stove in which the stones are separated from and indirectly heated by the fire and the flue gases
and which may be refuelled with several successive fuel loads also during sauna bathing
3.1003
test load
mass of test fuel declared in the operating instructions for the burning period
NOTE 1 to entry: The test load can be added as batch charges if this is indicated in the multi-firing sauna stove
instructions.
3.1004
burning period
period when test load is burned in multi-firing sauna stove
4 Characteristics
4.1 Load bearing capacity
Some appliances with an upper outlet may be able to carry the load of a chimney. The max. load the
appliance may carry shall be specified in the appliance installation instructions. The performance of the
appliance in relation to the ability to carry a chimney shall be determined in accordance A.4.10.4 of this
document.
If for an appliance with an upper outlet the ability to carry a chimney is specified the value of the
maximum load is to be given in [kg] as an integer according to EN 16510-1:2022, Table 22, no. 57 (m ).
chim
4.2 Protection of combustible materials
The performance of the appliance in relation to protection of combustible materials shall be determined
in accordance with A.4.10.4 and A.2.1001, Figure A.1005 of this document. The protection measure(s) as
specified shall not lead to an excess of the more than 65 K above ambient room temperature at the hottest
point of any adjacent floor, or 140 K above ambient room temperature at the hottest point of any adjacent
walls, ceiling or other structure constructed of combustible materials.
If necessary, the distances are increased until the temperature measured is below this value and the
specification of the protection measures needs to be adapted accordingly.
When tested in accordance with A.4.10 and A.2.1001 of this document, the protection measure(s) as
specified according to Table 1 shall be given as minimum distance to combustibles and if appropriate as
material type and thickness of protective insulation material.
The protection measures as specified shall be given in [mm] as an integer according to EN 16510-1:2022,
Table 22, no. 33, 34, 35, 36, 37, 38, 39 and 41 (d , d , d , d , dF, d , d , s). Minimum distance to adjacent
R S C P L B
combustible materials on side (d ) will be given in [mm] or [cm] in appliances’ technical datasheet and
PS
data plate.
Table 1 — Protection of combustible materials
Protection measure Declared clearance distance to Protective
combustible material or insulation material
thickness of protective if any
insulation material
[mm]
Minimum distance to  -
combustible materials - bottom
(d )
B
Minimum distance to  -
combustible materials – ceiling
(d )
C
Minimum distance to  -
combustible materials – rear (d )
R
Minimum distance to  -
combustible materials – side (d )
S
Minimum distance to  -
combustible materials – side
radiation area (d )
L
Minimum distance to adjacent  -
combustible materials in front
(e.g. sauna room benches) (d )
P
Minimum distance to adjacent  -
combustible materials on free
side (e.g. sauna room benches)
(d )
PS
Protective insulation material (s)
4.3 Carbon monoxide emission (CO)
The performance of the appliance in relation to carbon monoxide emission at nominal heat output shall
be determined in accordance A.4.7 of this document and with EN 16510-1:2022, 6.3.2.
The CO value if specified at nominal heat output is to be given in [mg/m ] as an integer according to EN
16510-1:2022, Table 22, no. 17 (CO (13 % O )).
nom 2
4.4 Nitrogen oxides (NO ) emissions
x
The performance of the appliance in relation to nitrogen oxides emissions at nominal heat output shall
be determined in accordance with A.4.7 of this document and EN 16510-1:2022, 6.3.3.
The NO value if specified at nominal heat output is to be given in [mg/m ] as an integer according to
x
EN 16510-1:2022, Table 22, no. 20 (NO (13 % O )).
xnom 2
4.5 Emission of organic gaseous compounds (OGC)
The performance of the appliance in relation to organic gaseous compounds emission at nominal heat
shall be determined in accordance with A.4.7 of this document and EN 16510-1:2022, 6.3.4.
The OGC value if specified at nominal heat output is to be given in [mg/m ] as an integer according to
EN 16510-1:2022, Table 22, no. 23 (OGC (13 % O )).
nom 2
4.6 Particulate matter (PM) emissions
The performance of the appliance in relation to particulate matter emissions at nominal heat output shall
be determined in accordance with A.4.7 of this document and EN 16510-1:2022, 6.3.5.
The particulate matter value if specified at nominal heat output is to be given in [mg/m ] as an integer
according to EN 16510-1:2022, Table 22, no. 26 (PM (13 % O )).
nom 2
4.7 Safety and accessibility in use
4.7.1 General
The data for the installation to a chimney are to be evaluated at nominal heat output. Specific data are to
be evaluated at safety test heat output.
4.7.2 Flue gas outlet temperature at nominal heat output
The performance of the appliance in relation to flue gas outlet temperature at nominal heat output shall
be determined in accordance with A.4.7 of this document and EN 16510-1:2022, 6.2.1.
The value of the flue gas outlet temperature for the installation of the appliance to a chimney if specified
is to be given in [°C] as an integer according to EN 16510-1:2022, Table 22, no. 47 (T ).
snom
4.7.3 Minimum flue draught at nominal heat output
The performance of the appliance in relation to the minimum flue draught at nominal heat output shall
be determined in accordance with A.4.7 of this document and EN 16510-1:2022, 6.5.
For nominal heat output the flue static pressure shall be kept within (12 ± 2) Pa in all power ranges.
Where this flue draught value of 12 Pa needs to be exceeded in order to obtain the declared specified
nominal heat output, the required flue draught shall be clearly stated in the appliance's installation
instructions.
The value of the minimum flue draught if specified at nominal heat output for the installation of the
appliance to a chimney is to be given in [Pa] as an integer according to EN 16510-1:2022, Table 22, no.
29 (p ).
nom
4.7.4 Flue gas mass flow at nominal heat output
The performance of the appliance in relation to the flue gas mass flow at nominal heat output shall be
determined in accordance with A.4.7 of this document and EN 16510-1:2022, 6.12.
The flue gas mass flow value if specified at nominal heat output for the installation of the appliance to a
chimney is to be given in [g/s] with 1 decimal according to EN 16510-1:2022, Table 22, no. 50 (ϕ ).
f,g nom
4.7.5 Fire safety of installation to the chimney
The performance of the appliance in relation to the flue gas temperature (mean value) at safety test shall
be determined in accordance with A.4.10.4 of this document.
The data for installation of the appliance to a chimney with regards to the fire safety if specified is to be
given as the Tclass of the chimney required according to EN 16510-1:2022, 6.2.2 and EN 16510-1:2022,
Table 22, no. 49.
4.8 Energy economy and heat retention
4.8.1 Space heat output at nominal heat output
The performance of the appliance in relation to space heat output at nominal heat output shall be
determined in accordance with A.4.7 of this document.
The space heat output of the appliance if specified at nominal heat output is to be given in [kW] with 1
decimal according to EN 16510-1:2022, Table 22, no. 2 (P ).
SHnom
For the proper performance of the appliance the following shall be considered as well for those essential
characteristics and descriptive features assessed during the nominal heat output test (A.4.7 of this
document).
Additional devices, such as flue gas outlet components, components built-in the flue ways, combustion
air supply control devices, charging doors and ash-pit doors, flue bypass devices, internal flue gas
diverters, front fire bars and/or draught regulators for the safety or function of the appliance may be
present.
Some of these devices are optional, but if present their influence on the performance of the appliance
shall be checked according to EN 16510-1:2022, 4.4.4, 4.4.6, 4.4.9, 4.4.11, 4.4.12, 4.4.13, 4.4.14, and 4.4.16.
4.8.2 Water heat output, if existing at nominal heat output
The performance of the appliance in relation to water heat output if existing at nominal heat output is
according to the scope not applicable as this document does not apply to appliances with water-bearing
parts or connection to a water system.
4.8.3 Efficiency at nominal heat output
The performance of the appliance in relation to efficiency at nominal heat output shall be determined in
accordance with A.4.7 of this document.
The efficiency of the appliance if specified at nominal heat output is to be given in [%] as an integer
according to EN 16510-1:2022, Table 22, no. 13 (η ).
nom
4.8.4 Electric power consumption at nominal heat output, if existing
The performance of the appliance in relation to electric power consumption at nominal heat output shall
be determined in accordance with A.4.7 of this document and EN 16510-1:2022, 6.11.
The electric power consumption of the appliance if specified at nominal heat output is to be given in [kW]
with 3 decimals according to EN 16510-1:2022, Table 22, no. 43 (el ).
max
4.8.5 Standby mode power consumption, if existing
The performance of the appliance in relation to standby mode power consumption at standby mode
(where appropriate) shall be determined in accordance with A.4.7 of this document and EN 16510-
1:2022, 6.11.
The standby mode power consumption of the appliance if specified is to be given in [kW] with 3 decimals
according to EN 16510-1:2022, Table 22, no. 42 (el ).
SB
4.9 Environmental sustainability
All relevant elements of the performance related to the whole life cycle of the appliance shall be identified
and enumerated on the basis on the information modules of EN 15804:2012+A2:2019.
The necessary environmental sustainability information shall be determined to enable the life cycle
analysis of the appliance concerned and the declaration of its performance in relation to the essential
characteristic environmental sustainability. This shall comprise in particular the definition of the
scenarios required for this complete period, including the reference service life, where appropriate.
The performance of the appliance in relation to the environmental sustainability shall be determined in
accordance with EN 16510-1:2022, Clause 8.
The environmental sustainability elements are given in Table 2.
Table 2 — Elements for the environmental sustainability
Environmental sustainability elements to be given in
kg CO equivalent
Global Warming Potential total (GWP-total)
kg CO equivalent
Global Warming Potential (GWP-fossil)
kg CO equivalent
Global Warming Potential (GWP-biogenic)
kg CO equivalent
Global Warming Potential land use and land use change (GWP-luluc)
Depletion potential of the stratospheric ozone layer (ODP) kg CFC 11 equivalent
+
Acidification potential, Accumulated Exceedance (AP)
mol H equivalent
Eutrophication potential, Fraction of nutrients reaching freshwater
kg PO equivalent
end compartment (EP-freshwater)
Eutrophication potential, Fraction of nutrients reaching marine end
kg N equivalent
compartment (EP-marine)
Eutrophication potential, Accumulated Exceedance (EP-terrestrial) mol N equivalent
Formation potential of tropospheric ozone (POCP) kg NMVOC equivalent
Abiotic depletion potential for non-fossil resources (ADP-minerals
kg Sb equivalent
and metals)
Abiotic depletion potential for fossil resources (ADP-fossil) MJ, net calorific value
Water (user) deprivation potential, deprivation-weighted water
m world equivalent
consumption (WDP)
deprived
Potential incidence of disease due to PM emissions (PM) Disease incidence
Potential Human exposure efficiency relative to U235 (IRP) kBq U235 equivalent
Eco-toxicity (freshwater) (ETP-fw) CTUe
Environmental sustainability elements to be given in
Potential Comparative Toxic Unit for ecosystems (ETP-fw) CTUe
Potential Comparative Toxic Unit for humans (HTP-c) CTUh
Potential Comparative Toxic Unit for humans (HTP-nc) CTUh
Potential soil quality index (SQP) dimensionless
Hazardous waste disposed kg
Non-hazardous waste disposed kg
Radioactive waste disposed kg
Use of renewable primary energy excluding renewable primary
MJ, net calorific value
energy resources used as raw materials
Use of renevable primary energy resources used as raw materials MJ, net calorific value
Total use of renewable primary energy resources (primary energy
MJ, net calorific value
and primary energy resources used as raw materials)
Use of non-renewable primary energy excluding non-renewable
MJ, net calorific value
primary energy resources used as raw materials
Use of non-renewable primary energy resources used as raw
MJ, net calorific value
materials
Total use of non-renewable primary energy resources (primary
MJ, net calorific value
energy and primary energy resources used as raw materials)
Use of secondary material kg
Use of renewable secondary fuels MJ, net calorific value
Use of non-renewable secondary fuels MJ, net calorific value
Use of net fresh water
m
Components for re-use kg
Materials for recycling kg
Materials for energy recovery kg
Exported energy MJ per energy carrier
5 Descriptive features
5.1 Data for potential use with room ventilation systems: type of appliance (in relation
to its tightness to the room)
The designation of the appliance in relation to the potential use with ventilation systems is to be given in
accordance with EN 16510-1:2022, 4.1.
5.2 Data for the building's statics: appliance's mass
The appliance’s mass in relation to the building’s statics is to be given in accordance with EN 16510-
1:2022, 7.2, paragraph 8).
5.3 Materials and construction elements
5.3.1 General
The shape and dimensions of the components and equipment and the method of design and manufacture
and, if assembled on site, the method of assembly and installation, shall ensure that, when operated as
specified in accordance with the test procedures of this document and exposed to the associated
mechanical, chemical and thermal stresses, the appliance shall operate reliably and safely such that
during normal operation no combustion gas posing a hazard can escape into the room in which the
appliance is installed nor can embers fall out.
Non-combustible materials (materials according to EN 16510-1:2022, 4.4.1.1) shall be used, except that
it shall be permissible to use combustible materials for the following applications:
— components or accessories fitted outside the appliance;
— internal components of controls and safety equipment;
— operating handles;
— electrical equipment.
5.3.2 General stresses
The proper operation of the appliance in relation to the general stresses to materials and construction
elements is to be tested in accordance with A.4.7, A.4.10 of this document and EN 16510-1:2022, 4.4.1
and 4.4.2.
5.3.3 Integral boiler or heat exchanger
As the scope of this document clearly states that appliances are not fitted with an integral boiler or heat
exchanger. The proper operation of the appliance’s integral boiler or heat exchanger is not relevant.
5.4 Risk of burning fuel falling out
The prevention of the risk of burning fuel falling out of the appliance is to be tested in accordance with
A.4.10.3 of this document and EN 16510-1:2022, 5.2.
5.5 Temperature rise in the fuel storage
The rise of the temperature above ambient temperature in the fuel storage is to be tested in accordance
with A.4.7 and A.4.10 of this document and EN 16510-1:2022, 5.4. This rise of the temperature shall not
exceed 65 K.
5.6 Temperature rise of the operating components
The rise of the temperature above ambient temperature of the operation components is to be tested in
accordance with A.4.7 of this document and EN 16510-1:2022, 5.5. This rise of the temperature shall not
exceed the material specific limits given in EN 16510-1:2022, 5.5.
5.7 Spillage of flue gases into the room
5.7.1 Possible spillage of CO, if relevant for the fuel type
The prevention of possible spillage of CO is to be tested in accordance with EN 16510-1:2022, 5.1 and
A.4.10.5 depending on the intended fuel type.
5.7.2 Open operation
The prevention of possible spillage of flue gases is to be tested in accordance with EN 16510-1:2022, 5.2
for appliances intended for open operation.
5.8 Cleanability
5.8.1 Heating surfaces
The safety of the heating surfaces especially in relation to cleanability is to be tested in accordance with
EN 16510-1:2022, 4.4.3.
5.8.2 Flueways
The safety of the flueways especially in relation to cleanability is to be tested in accordance with
EN 16510-1:2022, 4.4.5.
5.8.3 Ashpan
If an ashpan is fitted its safety especially in relation to cleanability is to be tested in accordance with
EN 16510-1:2022, 4.4.7.
5.8.4 Bottomgrate
If a bottomgrate is fitted its safety especially in relation to cleanability is to be tested in accordance with
EN 16510-1:2022, 4.4.8.
5.8.5 Damper
If a damper is fitted its safety especially in relation to cleanability is to be tested in accordance with
EN 16510-1:2022, 4.4.10.
5.8.6 Fan-cut-out-device
If a fan-cut-out-device is fitted its safety especially in relation to cleanability is to be tested in accordance
with EN 16510-1:2022, 4.4.10 and EN 16510-2-4:2022, A.4.401.
5.9 Strength and leak tightness of boiler shells
The strength and leak tightness of integrated boiler shells is not applicable to this specific type of
appliances. According to the scope, this document not applicable for appliances incorporating a boiler or
connected to a water system.
6 Assessment and verification of constancy of performance - AVCP
6.1 General
The technical details necessary for the implementation of the system of assessment and verification of
constancy of performance comprise provisions with regards to:
— the assessment of the performance of the residential solid fuel burning appliance, which may be
carried out on the basis of testing (including sampling), calculation, tabulated values or descriptive
documentation of the product and
— the applicable factory production control.
6.2 Assessment of performance
6.2.1 General
When the intention is to declare any performance related to characteristics included in Annex ZA of this
standard this shall be carried out on the basis of testing (including sampling), calculation, tabulated
values or descriptive documentation of the product, in accordance with clause 'characteristics'.
Assessment previously performed in accordance with the provisions of this document may be considered
provided that this assessment was made to the same or a more rigorous assessment method, under the
same AVCP system on the same product or products of similar design, construction and functionality,
such that the results are applicable to the product in question.
For the purposes of assessment, the products may be grouped into families, where it is considered that
the results for one or more characteristics from any one product within the family are representative for
that same characteristic for all products within that same family (see EN 16510-1:2022, Annex G).
Products may be grouped into different families for different characteristics.
In addition, the determination of the product type shall be
— carried out for all characteristics included in the standard for which it is intended to declare the
performance:
— on first application of this standard, or
— at the beginning of the production of a new or modified residential solid fuel burning appliance,
unless a member of the same product family, or
— at the beginning of a new or modifi
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.

Loading comments...