General Information

Abstract

IEC 61076-2-117:2026 This part covers shielded and unshielded, free and fixed circular connectors without breaking capacity (COC) for power, signal and data transmission, and specifies the common dimensions, mechanical, electrical and transmission characteristics and environmental requirements as well as test specifications, respectively.

Status
Published
Publication Date
16-Aug-2026
Technical Committee
SC 48B - Electrical connectors
Current Stage
PPUB - Publication issued
Start Date
17-Aug-2026
Completion Date
21-Aug-2026

Buy Documents

Standard

IEC 61076-2-117:2026 - Connectors for electrical and electronic equipment - Product requirements - Part 2-117: Detail specification for shielded and unshielded, free and fixed connectors M12 to M40 for power, auxiliary and data transmission with frequencies up to 600 MHz

ISBN:978-2-8327-1399-0
Release Date:17-Aug-2026
English language (91 pages)
sale 15% off
Preview
sale 15% off
Preview
Standard

iec61076-2-117{ed1.0}fr - Connecteurs pour équipements électriques et électroniques - Exigences de produit - Partie 2-117: Spécification particuliere pour les fiches et embases écrantées et non écrantées M12 a M40 pour la transmission de puissance, auxiliaire et de données a des fréquences jusqu’a 600 MHz

ISBN:978-2-8327-1399-0
Release Date:17-Aug-2026
English and French language (184 pages)
sale 15% off
Preview
sale 15% off
Preview

Overview

IEC 61076-2-117:2026 is an international standard published by the International Electrotechnical Commission (IEC). It defines the product requirements for shielded and unshielded, free and fixed circular connectors of sizes M12 to M40, designed for power, auxiliary, and data transmission at frequencies up to 600 MHz. These connectors, which feature both screw and quick-lock coupling mechanisms, are widely used for reliable signal, power, and data connections in industrial and electronic applications.

The standard specifies the common dimensions, mechanical, electrical, and transmission characteristics, as well as environmental performance and comprehensive test requirements to ensure interoperability and quality in demanding environments.

Key Topics

  • Connector Types Covered

    • Shielded and unshielded circular connectors
    • Free (plug) and fixed (socket) configurations
    • M12, M17, M23, and M40 interface sizes
  • Transmission Capabilities

    • Power: up to 600 V AC/DC, up to 70 A
    • Auxiliary circuits: up to 50 V, up to 30 A
    • Data: signal transmission up to 600 MHz, supporting industrial Ethernet
  • Mechanical & Electrical Requirements

    • Standardized interface and contact arrangements
    • Mating and unmating force parameters
    • Environmental categories (climatic suitability)
    • Protection ratings (e.g., IP degree of sealing)
    • Coupling mechanisms: screw (threaded) or quick-lock
  • Performance & Testing

    • Electrical and mechanical performance criteria (contact resistance, insulation resistance, withstand voltage)
    • Transmission parameters (insertion loss, return loss, crosstalk, characteristic impedance)
    • Robustness against mechanical shocks and vibrations
    • Detailed testing programs for qualification and quality assurance

Applications

IEC 61076-2-117:2026 connectors are engineered for use in a wide range of electrical and electronic equipment where dependable connections for power, control signals, and data are essential.

  • Industrial Automation:
    • Connection of sensors, actuators, controllers, and fieldbus devices
    • Single-cable solutions for integrated power and data, simplifying installation
  • Machine Building:
    • Power supply and data communication in machinery and assembly lines
  • Process Control:
    • Instrumentation and process sensors requiring shielded communication in harsh environments
  • Industrial Ethernet:
    • Supporting high-speed data transmission, compatible with Ethernet standards (IEEE 802.3 for 10BASE-T1, 100BASE-TX, 1GBASE-T, 10GBASE-T, etc.)
  • Transportation and Infrastructure:
    • Reliable connectivity in vehicles, railways, and infrastructure electronics

By adhering to IEC 61076-2-117:2026, manufacturers and system integrators ensure compatibility, safety, and performance for connectors in modern automation and communication systems.

Related Standards

The IEC 61076-2-117:2026 standard builds on and complements a suite of IEC and related international standards for connectors and compatibility:

  • IEC 61076 Series: General requirements and detail specifications for connectors for electrical and electronic equipment
  • IEC 61076-1: Common requirements for connector interfaces
  • IEC 61076-2: Circular connectors for industrial use
  • IEC 60050-581: International Electrotechnical Vocabulary - Electromechanical components for electronic equipment
  • IEEE 802.3: Ethernet standards for data communication
  • Other relevant parts of IEC/ISO standards covering product safety, environmental performance, and application-specific requirements

Adopting IEC 61076-2-117:2026 ensures compatibility and quality in connector technology for electrical and electronic systems worldwide, helping end users streamline design, procurement, and maintenance processes for industrial connectivity.

Buy Documents

Standard

IEC 61076-2-117:2026 - Connectors for electrical and electronic equipment - Product requirements - Part 2-117: Detail specification for shielded and unshielded, free and fixed connectors M12 to M40 for power, auxiliary and data transmission with frequencies up to 600 MHz

ISBN:978-2-8327-1399-0
Release Date:17-Aug-2026
English language (91 pages)
sale 15% off
Preview
sale 15% off
Preview
Standard

iec61076-2-117{ed1.0}fr - Connecteurs pour équipements électriques et électroniques - Exigences de produit - Partie 2-117: Spécification particuliere pour les fiches et embases écrantées et non écrantées M12 a M40 pour la transmission de puissance, auxiliaire et de données a des fréquences jusqu’a 600 MHz

ISBN:978-2-8327-1399-0
Release Date:17-Aug-2026
English and French language (184 pages)
sale 15% off
Preview
sale 15% off
Preview

Frequently Asked Questions

IEC 61076-2-117:2026 is a standard published by the International Electrotechnical Commission (IEC). Its full title is "Connectors for electrical and electronic equipment - Product requirements - Part 2-117: Detail specification for shielded and unshielded, free and fixed connectors M12 to M40 for power, auxiliary and data transmission with frequencies up to 600 MHz". This standard covers: IEC 61076-2-117:2026 This part covers shielded and unshielded, free and fixed circular connectors without breaking capacity (COC) for power, signal and data transmission, and specifies the common dimensions, mechanical, electrical and transmission characteristics and environmental requirements as well as test specifications, respectively.

IEC 61076-2-117:2026 This part covers shielded and unshielded, free and fixed circular connectors without breaking capacity (COC) for power, signal and data transmission, and specifies the common dimensions, mechanical, electrical and transmission characteristics and environmental requirements as well as test specifications, respectively.

IEC 61076-2-117:2026 is classified under the following ICS (International Classification for Standards) categories: 31.220.10 - Plug-and-socket devices. Connectors. The ICS classification helps identify the subject area and facilitates finding related standards.

IEC 61076-2-117:2026 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)


IEC 61076-2-117 ®
Edition 1.0 2026-08
INTERNATIONAL
STANDARD
Connectors for electrical and electronic equipment - Product requirements -
Part 2-117: Detail specification for shielded and unshielded, free and fixed
connectors M12 to M40 for power, auxiliary and data transmission with
frequencies up to 600 MHz
ICS 31.220.10  ISBN 978-2-8327-1399-0

All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or
by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from either
IEC or IEC's member National Committee in the country of the requester. If you have any questions about IEC copyright
or have an enquiry about obtaining additional rights to this publication, please contact the address below or your local
IEC member National Committee for further information.

IEC Secretariat Tel.: +41 22 919 02 11
3, rue de Varembé info@iec.ch
CH-1211 Geneva 20 www.iec.ch
Switzerland
About the IEC
The International Electrotechnical Commission (IEC) is the leading global organization that prepares and publishes
International Standards for all electrical, electronic and related technologies.

About IEC publications
The technical content of IEC publications is kept under constant review by the IEC. Please make sure that you have the
latest edition, a corrigendum or an amendment might have been published.

IEC publications search - IEC Products & Services Portal - products.iec.ch
webstore.iec.ch/advsearchform Discover our powerful search engine and read freely all the
The advanced search enables to find IEC publications by a publications previews, graphical symbols and the glossary.
variety of criteria (reference number, text, technical With a subscription you will always have access to up to date
committee, …). It also gives information on projects, content tailored to your needs.
replaced and withdrawn publications.
Electropedia - www.electropedia.org
The world's leading online dictionary on electrotechnology,
IEC Just Published - webstore.iec.ch/justpublished
Stay up to date on all new IEC publications. Just Published containing more than 22 500 terminological entries in English
details all new publications released. Available online and and French, with equivalent terms in 25 additional languages.
once a month by email. Also known as the International Electrotechnical Vocabulary
(IEV) online.
IEC Customer Service Centre - webstore.iec.ch/csc
If you wish to give us your feedback on this publication or
need further assistance, please contact the Customer
Service Centre: sales@iec.ch.
CONTENTS
FOREWORD . 6
INTRODUCTION . 8
1 Scope . 9
2 Normative references . 9
3 Terms and definitions . 12
4 Technical information . 12
4.1 Systems of levels – compatibility levels, in accordance with IEC 61076-1 . 12
4.1.1 Performance level . 12
4.1.2 Compatibility levels in accordance with IEC 61076-1 . 12
4.2 Classification into climatic categories . 12
4.3 Clearance and creepage distances . 12
4.4 Current carrying capacity . 12
4.5 Marking . 12
4.6 Safety aspects . 12
5 Dimensional information . 13
5.1 General . 13
5.2 Coding . 13
5.3 Survey of styles and variants . 16
5.3.1 General . 16
5.3.2 Fixed connectors . 17
5.3.3 Free connectors. 22
5.4 Interface dimensions . 26
5.4.1 M12 . 26
5.4.2 M17 . 32
5.4.3 M23 . 39
5.4.4 M40 . 46
5.5 Engagement (mating) information . 54
5.6 Gauges . 58
6 Characteristics . 58
6.1 General . 58
6.2 Contact element assignment . 59
6.3 Classification into climatic category . 66
6.4 Electrical characteristics . 66
6.4.1 Voltage information for creepage and clearance distances . 66
6.4.2 Voltage proof . 67
6.4.3 Current-carrying capacity . 68
6.4.4 Current rating . 69
6.4.5 Contact resistance – interface only (separable fixed and free contact) . 69
6.4.6 Shield resistance . 69
6.4.7 Contact resistance . 70
6.4.8 Insulation resistance . 70
6.4.9 Characteristic impedance (data transmission) . 71
6.5 Transmission performance . 71
6.5.1 General . 71
6.5.2 Insertion loss . 71
6.5.3 Return loss . 71
6.5.4 Near-end cross talk (NEXT) . 72
6.5.5 Far-end cross talk (FEXT). 72
6.5.6 Transverse conversion loss (TCL) . 72
6.5.7 Transverse conversion transfer loss (TCTL) . 73
6.5.8 Transfer impedance . 73
6.5.9 Coupling attenuation . 73
6.5.10 Power sum alien (exogenous) NEXT (PS ANEXT) . 74
6.5.11 Power sum alien (exogenous) FEXT (PS AFEXT) . 74
6.5.12 Propagation delay . 74
6.6 Mechanical characteristics . 75
6.6.1 IP degree of protection . 75
6.6.2 Mechanical operation . 75
6.6.3 Effectiveness of connector coupling devices . 75
6.6.4 Insertion and withdrawal forces . 76
6.6.5 Polarizing method . 76
6.6.6 Vibration (sinusoidal) . 77
6.6.7 Shock . 77
6.6.8 Severities . 77
7 Tests and test schedule . 78
7.1 General . 78
7.2 Mounting of specimens . 78
7.2.1 General . 78
7.2.2 Arrangement for contact resistance measurement . 78
7.2.3 Arrangement for dynamical stress tests . 79
7.2.4 Wiring of specimens . 79
7.3 Test procedures and measuring methods . 79
7.4 Preconditioning . 80
7.5 Test schedules. 80
7.5.1 General . 80
7.5.2 Basic (minimum) test schedule . 80
7.5.3 Full test schedule . 80
7.5.4 Test group AP – Dynamic climatic . 81
7.5.5 Test group BP – Mechanical endurance . 83
7.5.6 Test group CP – Electrical load . 84
7.5.7 Test group DP – Chemical resistivity . 86
7.5.8 Test group EP – Connection method tests . 86
7.5.9 Test group FP – Electrical transmission . 87
7.5.10 Test group GP – Transfer impedance and coupling attenuation . 88
7.5.11 Test Group HP – Current-carrying capacity . 88
Annex A (informative) Coding orientation . 89
A.1 Coding orientation M17 . 89
A.2 Coding orientation M23 . 89
A.3 Coding orientation M40 . 90
Bibliography . 91

Figure 1 – Fixed connector, male or female contacts, straight version, with a square
flange front mounting . 18
Figure 2 – Fixed connector, male or female contacts, straight version,
single hole mounting, with or without mounting orientation . 19
Figure 3 – Fixed connector, male or female contacts, right-angled version, with a
square flange front mounting . 20
Figure 4 – Fixed connector, male or female contacts, right-angled version,
single hole mounting . 21
Figure 5 – Rewirable connector, male or female contacts, straight version . 23
Figure 6 – Non-rewirable connector, male or female contacts, straight version . 24
Figure 7 – Rewirable connector, male or female contacts, straight version . 24
Figure 8 – Non-rewirable connector, male or female contacts, straight version . 25
Figure 9 – M12 mating dimensions for the coding Type 1 for male connectors . 26
Figure 10 – M12 mating dimensions for the coding Type 2 for male connectors . 27
Figure 11 – M12 mating dimensions for the coding Type 3 and style with male contacts . 29
Figure 12 – M12 mating dimensions for the female connectors
(at the example of coding Type 1 / 2) . 31
Figure 13 – M12 mating dimensions for the fixed connectors (side view) . 32
Figure 14 – Common dimensions for M17 Type 1/1A/1B male connectors . 33
Figure 15 – Detail dimensions for M17 Type 1/1A/1B male connectors . 34
Figure 16 – Common dimensions for M17 Type 2/2A/2B male connectors . 35
Figure 17 – Detail dimensions for M17 Type 2/2A/2B male connectors . 36
Figure 18 – Pin dimensions for M17 Type 1/1A/1B/2/2A/2B male connectors . 37
Figure 19 – M17 mating dimensions for the fixed connector (side view) . 38
Figure 20 – Common dimensions for M23 Type 1/1A male connectors . 39
Figure 21 – Detail dimensions for M23 Type 1/1A male connector . 40
Figure 22 – Common dimensions for M23 Type2/2A male connectors . 41
Figure 23 – Detail dimensions for M23 Type 2/2A male connector . 42
Figure 24 – Pin dimensions for M23 Type 1/1A/2/2A male connectors . 43
Figure 25 – M23 mating dimensions for the fixed connector (side view) . 45
Figure 26 – Common dimensions for M40 Type1/1A male connectors . 46
Figure 27 – Detail dimensions for M40 Type1/1A male connector . 47
Figure 28 – Common dimensions for M40 Type2/2A male connectors . 48
Figure 29 – Detail dimensions for M40 Type2/2A male connector . 49
Figure 30 – Pin dimensions for M40 Type 1/1A/2/2A male connectors . 50
Figure 31 – M40 mating dimensions for the fixed connectors (side view) . 52
Figure 32 – Engagement (mating) variants . 54
Figure 33 – Gauge dimension . 58
Figure 34 – Contact element assignments, front views, M12, Type 1 . 59
Figure 35 – Contact element assignments, front views, M12, Type 2 . 59
Figure 36 – Contact element assignments, front views, M12, Type 3 . 60
Figure 37 – Contact element assignments, front views, M17, Type 1/1A . 60
Figure 38 – Contact element assignments, front views, M17, Type 1B . 61
Figure 39 – Contact element assignments, front views, M17, Type 2/2A . 61
Figure 40 – Contact element assignments, front views, M17, Type 2B . 62
Figure 41 – Contact element assignments, front views, M23, Type 1/1A . 63
Figure 42 – Contact element assignments, front views, M23, Type 2/2A . 63
Figure 43 – Contact element assignments, front views, M40, Type 1/1A . 64
Figure 44 – Contact element assignments, front views, M40, Type 2/2A . 65
Figure 45 – Contact resistance arrangement . 78
Figure 46 – Arrangement for vibration and mechanical shock tests . 79
Figure A.1 – Orientation example for M17 angled outlets to the bottom . 89
Figure A.2 – Orientation example for M23 angled outlets to the bottom . 89
Figure A.3 – Orientation example for M40 angled outlets to the bottom . 90

Table 1 – Coding . 13
Table 2 – Styles of fixed connectors . 17
Table 3 – Dimensions of styles Mxx_DM and Mxx_DF, Figure 1 . 19
Table 4 – Dimensions of styles Mxx_EM, Mxx_EF, Mxx_GM and Mxx_GF, Figure 2 . 20
Table 5 – Dimensions of styles Mxx_DM90 and Mxx_DF90, Figure 3 . 21
Table 6 – Dimensions of style Mxx_EM90 and Mxx_EF90, Figure 4 . 22
Table 7 – Styles of free connectors . 22
Table 8 – Dimensions of styles Mxx_JM and Mxx_JF, Figure 5 . 23
Table 9 – Dimensions of style Mxx_LM and Mxx_LF, Figure 6 . 24
Table 10 – Dimensions of styles Mxx_JM and Mxx_JF, Figure 7 . 25
Table 11 – Dimensions for styles Mxx_LMC and Mxx_LFC, Figure 8 . 25
Table 12 – Dimensions for Figure 9 and Figure 10 and Figure 11 . 28
Table 13 – Dimensions for Figure 9, Figure 10 and Figure 11 . 30
Table 14 – Dimensions for Figure 12 . 31
Table 15 – Dimensions for Figure 13 . 32
Table 16 – Dimensions for Figure 14 . 33
Table 17 – Dimensions for Figure 15 . 34
Table 18 – Dimensions for Figure 16 . 35
Table 19 – Dimensions for Figure 17 . 36
Table 20 – Dimensions for Figure 18 . 37
Table 21 – Dimensions for Figure 19 . 38
Table 22 – Dimensions for Figure 20 . 39
Table 23 – Dimensions for Figure 21 . 40
Table 24 – Dimensions for Figure 22 . 41
Table 25 – Dimensions for Figure 23 . 42
Table 26 – Dimensions for Figure 24 . 44
Table 27 – Dimensions for Figure 25 . 45
Table 28 – Dimensions for Figure 26 . 46
Table 29 – Dimensions for Figure 27 . 47
Table 30 – Dimensions for Figure 28 . 48
Table 31 – Dimensions for Figure 29 . 49
Table 32 – Dimensions for Figure 30 . 51
Table 33 – Dimensions for Figure 31 . 53
Table 34 – Connector dimensions in mated and locked position . 55
Table 35 – Gauges . 58
Table 36 – Contact element assignments M12 . 60
Table 37 – Contact element assignments M17 . 62
Table 38 – Contact element assignments M23 . 64
Table 39 – Contact element assignments M40 . 65
Table 40 – Pin sizes . 66
Table 41 – Climatic category . 66
Table 42 – Rated voltage . 67
Table 43 – Voltage proof . 68
Table 44 – Current ratings of connectors . 69
Table 45 – Maximum contact resistance . 69
Table 46 – Maximum input to output DC resistance . 70
Table 47 – Maximum input to output DC resistance unbalanced . 70
Table 48 – Minimum insulation resistance . 70
Table 49 – Insertion loss requirements . 71
Table 50 – Return loss requirements . 71
Table 51 – Near-end cross talk requirements . 72
Table 52 – Far-end cross talk requirements . 72
Table 53 – Transverse conversion loss requirements . 72
Table 54 – Transverse conversion transfer loss requirements . 73
Table 55 – Transfer impedance requirements . 73
Table 56 – Coupling attenuation requirements . 73
Table 57 – Power sum alien NEXT requirements . 74
Table 58 – Power sum alien FEXT requirements . 74
Table 59 – Propagation delay requirements . 74
Table 60 – Number of cycles of mechanical operations . 75
Table 61 – Minimum forces for the quick-locking mechanism . 76
Table 62 – Insertion and withdrawal forces . 76
Table 63 – Polarizing insertion force . 76
Table 64 – Severities for shock and vibration (sinusoidal) . 77
Table 65 – Number of test specimens and contacts . 80
Table 66 – Test group P . 80
Table 67 – Test group AP . 81
Table 68 – Test group BP . 83
Table 69 – Test group CP . 84
Table 70 – Test group DP . 86
Table 71 – Test group EP . 86
Table 72 – Test group FP . 87
Table 73 – Test group GP . 88
Table 74 – Test group HP . 88

INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
Connectors for electrical and electronic equipment -
Product requirements -
Part 2-117: Detail specification for shielded and unshielded, free and fixed
connectors M12 to M40 for power, auxiliary and data transmission with
frequencies up to 600 MHz
FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote international
co-operation on all questions concerning standardization in the electrical and electronic fields. To this end and
in addition to other activities, IEC publishes International Standards, Technical Specifications, Technical Reports,
Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC Publication(s)”). Their
preparation is entrusted to technical committees; any IEC National Committee interested in the subject dealt with
may participate in this preparatory work. International, governmental and non-governmental organizations liaising
with the IEC also participate in this preparation. IEC collaborates closely with the International Organization for
Standardization (ISO) in accordance with conditions determined by agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence between
any IEC Publication and the corresponding national or regional publication shall be clearly indicated in the latter.
5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity
assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any
services carried out by independent certification bodies.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) IEC draws attention to the possibility that the implementation of this document may involve the use of (a)
patent(s). IEC takes no position concerning the evidence, validity or applicability of any claimed patent rights in
respect thereof. As of the date of publication of this document, IEC had not received notice of (a) patent(s), which
may be required to implement this document. However, implementers are cautioned that this may not represent
the latest information, which may be obtained from the patent database available at https://patents.iec.ch. IEC
shall not be held responsible for identifying any or all such patent rights.
IEC 61076-2-117 has been prepared by subcommittee 48B: Electrical connectors, of IEC
technical committee 48: Electrical connectors and mechanical structures for electrical and
electronic equipment. It is an International Standard.
The text of this International Standard is based on the following documents:
Draft Report on voting
48B/3208/FDIS 48B/3222/RVD
Full information on the voting for its approval can be found in the report on voting indicated in
the above table.
The language used for the development of this International Standard is English.
This document was drafted in accordance with ISO/IEC Directives, Part 2, and developed in
accordance with ISO/IEC Directives, Part 1 and ISO/IEC Directives, IEC Supplement, available
at www.iec.ch/members_experts/refdocs. The main document types developed by IEC are
described in greater detail at www.iec.ch/publications.
A list of all parts in the IEC 61076 series, published under the general title Connectors for
electrical and electronic equipment – Product requirements, can be found on the IEC website.
The committee has decided that the contents of this document will remain unchanged until the
stability date indicated on the IEC website under webstore.iec.ch in the data related to the
specific document. At this date, the document will be
– reconfirmed,
– withdrawn, or
– revised.
INTRODUCTION
IEC SC 48B – Electrical connectors IEC 61076-2-117 Ed. 1
Specification available from:
IEC General secretariat or from the addresses
shown on the inside cover.
DETAIL SPECIFICATION in accordance with
IEC 61076-2
Shielded and unshielded circular connectors (as all the
connectors described in this document are equipped
with shielded data transmission portions, the attribute
“shielded” or “unshielded” refers to the additional
presence or lack of a shielded connector body) for
power, auxiliary and data applications with M12, M17,
M23, M40 screw- and quick-locking.
Power
up to 600 V AC/DC and up to 70 A
Auxiliary
up to 50 V AC /DC and up to 30 A
Data
up to 600 MHz
Male and female contacts
Rewirable
Non-rewirable
Fixed- and rewirable connectors with male or female
contacts, mateable with Mxx screw- or quick-locking
plugs.
Free cable connectors
Fixed connectors:
Straight connectors
Right-angled connectors
Flange mounting
Single hole panel mounting
1 Scope
This part of IEC 61076-2 covers shielded and unshielded, free and fixed circular connectors
without breaking capacity (COC) for power, signal and data transmission, and specifies the
common dimensions, mechanical, electrical and transmission characteristics and environmental
requirements as well as test specifications, respectively.
NOTE 1 As all the connectors described in this document are equipped with shielded data transmission portions,
the attribute “shielded” or “unshielded” refers to the additional presence or lack of a shielded connector body.
The connectors described in this document are equipped with an M12, M17, M23 or M40
screw-locking mechanism or a quick-locking mechanism with a size derived from those.
Fixed and rewirable connectors with male or female contacts, mateable with Mxx
screw- or quick-locking plugs.
This document provides multiple mating interfaces each of which is associated with a coding
preventing the mating of incompatible male and female connectors. The individual codings differ
by their numbers of ways, pin layouts and thicknesses, and thus by their power and data
transmission capabilities. These codings are referred to as “Type x” where ‘x’ represents an
Arabic number.
The connectors described in this document are intended to be used in one-cable automation
applications which require various combinations and levels of power up to 600 V AC/ DC and
up to 70 A, and either signal or data transmission, or both, with frequencies up to 600 MHz.
NOTE 2 The requirements (or information) described in this document facilitate data transmission through the
following Ethernet media systems as defined in IEEE 802.3:
– single-pair Ethernet (10BASE-T1, 100BASE-T1, 1000BASE-T1);
– Fast Ethernet (100BASE-TX);
– Gigabit Ethernet (1000BASE-T);
– 10-gigabit Ethernet (10GBASE-T).
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content
constitutes requirements of this document. For dated references, only the edition cited applies.
For undated references, the latest edition of the referenced document (including any
amendments) applies.
IEC 60050-581, International Electrotechnical Vocabulary - Chapter 581: Electromechanical
components for electronic equipment
IEC 60068-1, Environmental testing - Part 1: General and guidance
IEC 60068-2-60, Environmental testing - Part 2-60: Tests - Test Ke: Flowing mixed gas
corrosion test
IEC 60352 (all parts), Solderless connections
IEC 60512-1, Connectors for electrical and electronic equipment - Tests and measurements -
Part 1: Generic specification
IEC 60512-1-1, Connectors for electronic equipment - Tests and measurements - Part 1-1:
General examination - Test 1a: Visual examination
IEC 60512-1-2, Connectors for electronic equipment - Tests and measurements - Part 1-2:
General examination - Test 1b: Examination of dimension and mass
IEC 60512-2-1, Connectors for electronic equipment - Tests and measurements - Part 2-1:
Electrical continuity and contact resistance tests - Test 2a: Contact resistance - Millivolt level
method
IEC 60512-2-5, Connectors for electronic equipment - Tests and measurements - Part 2-5:
Electrical continuity and contact resistance tests - Test 2e: Contact disturbance
IEC 60512-3-1, Connectors for electronic equipment - Tests and measurements - Part 3-1:
Insulation tests - Test 3a: Insulation resistance
IEC 60512-4-1, Connectors for electronic equipment - Tests and measurements - Part 4-1:
Voltage stress tests - Test 4a: Voltage proof
IEC 60512-5-2, Connectors for electronic equipment - Tests and measurements - Part 5-2:
Current-carrying capacity tests - Test 5b: Current-temperature derating
IEC 60512-6-3, Connectors for electronic equipment - Tests and measurements - Part 6-3:
Dynamic stress tests - Test 6c: Shock
IEC 60512-6-4, Connectors for electronic equipment - Tests and measurements - Part 6-4:
Dynamic stress tests - Test 6d: Vibration (sinusoidal)
IEC 60512-9-1, Connectors for electronic equipment - Tests and measurements - Part 9-1:
Endurance tests - Test 9a: Mechanical operation
IEC 60512-9-2, Connectors for electronic equipment - Tests and measurements - Part 9-2:
Endurance tests - Test 9b: Electrical load and temperature
IEC 60512-11-1, Connectors for electrical and electronic equipment - Tests and
measurements - Part 11: Climatic tests - Test 11a - Climatic sequence
IEC 60512-11-4, Connectors for electronic equipment - Tests and measurements - Part 11-4:
Climatic tests - Test 11d: Rapid change of temperature
IEC 60512-11-7, Connectors for electronic equipment - Tests and measurements - Part 11-7:
Climatic tests - Test 11g: Flowing mixed gas corrosion test
IEC 60512-11-9, Connectors for electronic equipment - Tests and measurements - Part 11-9:
Climatic tests - Test 11i: Dry heat
IEC 60512-11-10, Connectors for electronic equipment - Tests and measurements – Part 11-10:
Climatic tests - Test 11j: Cold
IEC 60512-11-12, Connectors for electronic equipment - Tests and measurements – Part 11-12:
Climatic tests - Test 11m: Damp heat, cyclic
IEC 60512-13-2, Connectors for electronic equipment - Tests and measurements - Part 13-2:
Mechanical operation tests - Test 13b: Insertion and withdrawal forces
IEC 60512-13-5, Connectors for electronic equipment - Tests and measurements - Part 13-5:
Mechanical operation tests - Test 13e: Polarizing and keying method
IEC 60512-15-6, Connectors for electronic equipment - Tests and measurements - Part 15-6:
Connector tests (mechanical) - Test 15f: Effectiveness of connector coupling devices
IEC 60512-16-5, Connectors for electronic equipment - Tests and measurements - Part 16-5:
Mechanical tests on contacts and terminations - Test 16e: Gauge retention force (resilient
contacts)
IEC 60512-19-3, Electromechanical components for electronic equipment - Basic testing
procedures and measuring methods - Part 19: Chemical resistance tests - Section 3: Test 19c -
Fluid resistance
IEC 60512-25-9, Connectors for electronic equipment - Tests and measurements - Part 25-9:
Signal integrity tests - Test 25i: Alien crosstalk
IEC 60512-26-100, Connectors for electronic equipment - Tests and measurements -
Part 26-100: Measurement setup, test and reference arrangements and measurements for
connectors according to IEC 60603-7 - Tests 26a to 26g
IEC 60512-29-100, Connectors for electronic equipment - Tests and measurements -
Part 29-100: Signal integrity tests up to 500 MHz on M12 style connectors - Tests 29a to 29g
IEC 60529:1989, Degrees of protection provided by enclosures (IP Code)
IEC 60529:1989/AMD1:1999
IEC 60529:1989/AMD2:2013
IEC 60664-1:2020, Insulation coordination for equipment within low-voltage systems - Part 1:
Principles, requirements and tests
IEC 60603-7-1:2011, Connectors for electronic equipment - Part 7-1: Detail specification for
8-way, shielded, free and fixed connectors
IEC 60603-7-3:2010, Connectors for electronic equipment - Part 7-3: Detail specification for
8-way, shielded, free and fixed connectors, for data transmission with frequencies up to
100 MHz
IEC 61076-1, Connectors for electronic equipment - Product requirements - Part 1: Generic
specification
IEC 61076-2, Connectors for electronic equipment - Product requirements - Part 2: Sectional
specification for circular connectors
IEC 61984:2008, Connectors - Safety requirements and tests
IEC 62153-4-12, Metallic communication cable test methods - Part 4-12: Electromagnetic
compatibility (EMC) - Coupling attenuation or screening attenuation of connecting hardware -
Absorbing clamp method
IEC 63171:2021, Connectors for electrical and electronic equipment - Shielded or unshielded
free and fixed connectors for balanced single-pair data transmission with current carrying
capacity - General requirements and tests
ISO 21920-1, Geometrical product specifications (GPS) - Surface texture: Profile - Part 1:
Indication of surface texture
3 Terms and definitions
For the purposes of this document, the terms and definitions given in IEC 60050-581,
IEC 61076-1, IEC 61076-2 and IEC 60512-1 apply.
ISO and IEC maintain terminology databases for use in standardization at the following
addresses:
– IEC Electropedia: available at https://www.electropedia.org/
– ISO Online browsing platform: available at https://www.iso.org/obp
4 Technical information
4.1 Systems of levels – compatibility levels, in accordance with IEC 61076-1
4.1.1 Performance level
Connectors in accordance with this document are classified by mating performance level (MPL).
See 6.6.2 for details.
4.1.2 Compatibility levels in accordance with IEC 61076-1
a) Intermateability
Intermateability (level 2 of IEC 61076-1) standardizes only dimensions of electrical and
mechanical interfaces. Intermateability shall be ensured by application of the “Go” and “No-
Go” gauge requirements in the standards that can be referenced, and adherence to the
dimensional requirements within.
b) Interoperability
Interoperability of different connectors shall be ensured by meeting the specified interface
dimensions and the requirements of 6.4 and
...


IEC 61076-2-117 ®
Edition 1.0 2026-08
NORME
INTERNATIONALE
Connecteurs pour équipements électriques et électroniques - Exigences de
produit
Partie 2-117: Spécification particulière pour les fiches et embases écrantées et
non écrantées M12 à M40 pour la transmission de puissance, auxiliaire et de
données à des fréquences jusqu’à 600 MHz
ICS 31.220.10  ISBN 978-2-8327-1399-0

Droits de reproduction réservés. Sauf indication contraire, aucune partie de cette publication ne peut être reproduite ni
utilisée sous quelque forme que ce soit et par aucun procédé, électronique ou mécanique, y compris la photocopie et
les microfilms, sans l'accord écrit de l'IEC ou du Comité national de l'IEC du pays du demandeur. Si vous avez des
questions sur le copyright de l'IEC ou si vous désirez obtenir des droits supplémentaires sur cette publication, utilisez
les coordonnées ci-après ou contactez le Comité national de l'IEC de votre pays de résidence.

IEC Secretariat Tel.: +41 22 919 02 11
3, rue de Varembé info@iec.ch
CH-1211 Geneva 20 www.iec.ch
Switzerland
A propos de l'IEC
La Commission Electrotechnique Internationale (IEC) est la première organisation mondiale qui élabore et publie des
Normes internationales pour tout ce qui a trait à l'électricité, à l'électronique et aux technologies apparentées.

A propos des publications IEC
Le contenu technique des publications IEC est constamment revu. Veuillez vous assurer que vous possédez l’édition la
plus récente, un corrigendum ou amendement peut avoir été publié.

Recherche de publications IEC -  IEC Products & Services Portal - products.iec.ch
webstore.iec.ch/advsearchform Découvrez notre puissant moteur de recherche et consultez
La recherche avancée permet de trouver des publications gratuitement tous les aperçus des publications, symboles
IEC en utilisant différents critères (numéro de référence, graphiques et le glossaire. Avec un abonnement, vous aurez
texte, comité d’études, …). Elle donne aussi des toujours accès à un contenu à jour adapté à vos besoins.
informations sur les projets et les publications remplacées
ou retirées. Electropedia - www.electropedia.org
Le premier dictionnaire d'électrotechnologie en ligne au
IEC Just Published - webstore.iec.ch/justpublished monde, avec plus de 22 500 articles terminologiques en
Restez informé sur les nouvelles publications IEC. Just anglais et en français, ainsi que les termes équivalents
dans 25 langues additionnelles. Egalement appelé
Published détaille les nouvelles publications parues.
Disponible en ligne et une fois par mois par email. Vocabulaire Electrotechnique International (IEV) en ligne.

Service Clients - webstore.iec.ch/csc
Si vous désirez nous donner des commentaires sur cette
publication ou si vous avez des questions contactez-
nous: sales@iec.ch.
SOMMAIRE
AVANT-PROPOS . 7
INTRODUCTION . 9
1 Domaine d’application . 10
2 Références normatives . 10
3 Termes et définitions . 13
4 Informations techniques . 13
4.1 Systèmes de niveaux – Niveaux de compatibilité, conformément à
l’IEC 61076-1 . 13
4.1.1 Niveaux de performances . 13
4.1.2 Niveaux de compatibilité conformément à l’IEC 61076-1 . 13
4.2 Classification en catégories climatiques . 13
4.3 Distances d’isolement et lignes de fuite . 13
4.4 Courant admissible . 13
4.5 Marquage . 13
4.6 Aspects de sécurité . 13
5 Informations relatives aux dimensions . 14
5.1 Généralités . 14
5.2 Détrompage . 14
5.3 Description des modèles et des variantes . 17
5.3.1 Généralités . 17
5.3.2 Embases . 18
5.3.3 Fiches . 23
5.4 Dimensions de l’interface . 27
5.4.1 M12 . 27
5.4.2 M17 . 33
5.4.3 M23 . 40
5.4.4 M40 . 47
5.5 Informations relatives à l’accouplement . 55
5.6 Calibres . 59
6 Caractéristiques . 59
6.1 Généralités . 59
6.2 Affectation des éléments de contact . 60
6.3 Classification en catégories climatiques . 67
6.4 Caractéristiques électriques . 67
6.4.1 Informations relatives aux lignes de fuite et distances d’isolement . 67
6.4.2 Tension de tenue . 68
6.4.3 Courant admissible . 69
6.4.4 Courant assigné . 70
6.4.5 Résistance de contact – à l’interface uniquement (contact séparable
entre embase et fiche) . 70
6.4.6 Résistance du blindage . 70
6.4.7 Résistance de contact . 71
6.4.8 Résistance d’isolement . 71
6.4.9 Impédance caractéristique (transmission de données) . 72
6.5 Performance de transmission . 72
6.5.1 Généralités . 72
6.5.2 Perte d’insertion . 72
6.5.3 Affaiblissement de réflexion . 72
6.5.4 Paradiaphonie (NEXT) . 73
6.5.5 Télédiaphonie (FEXT) . 73
6.5.6 Perte de conversion transverse (TCL). 73
6.5.7 Perte de transfert de conversion transverse (TCTL) . 74
6.5.8 Impédance de transfert . 74
6.5.9 Affaiblissement de couplage . 75
6.5.10 Puissance cumulée de paradiaphonie exogène (PS ANEXT) . 75
6.5.11 Puissance cumulée de télédiaphonie exogène (PS AFEXT) . 76
6.5.12 Temps de propagation . 76
6.6 Caractéristiques mécaniques . 76
6.6.1 Degré de protection IP . 76
6.6.2 Fonctionnement mécanique . 77
6.6.3 Efficacité des dispositifs d’accouplement des connecteurs . 77
6.6.4 Forces d’insertion et d’extraction . 78
6.6.5 Méthode de détrompage . 78
6.6.6 Vibrations (sinusoïdales) . 78
6.6.7 Chocs . 79
6.6.8 Sévérités . 79
7 Essais et programme d’essais . 79
7.1 Généralités . 79
7.2 Montage des spécimens . 80
7.2.1 Généralités . 80
7.2.2 Montage pour la mesure de la résistance de contact . 80
7.2.3 Montage pour les essais de contraintes dynamiques . 81
7.2.4 Câblage des spécimens . 81
7.3 Procédures d’essai et méthodes de mesure . 81
7.4 Préconditionnement . 82
7.5 Programmes d’essai . 82
7.5.1 Généralités . 82
7.5.2 Programme d’essai de base (minimal) . 82
7.5.3 Programme d’essais complet . 82
7.5.4 Groupe d’essais AP – Essais dynamiques climatiques . 83
7.5.5 Groupe d’essais BP – Essais d’endurance mécanique . 85
7.5.6 Groupe d’essais CP – Charge électrique . 87
7.5.7 Groupe d’essais DP – Résistivité chimique . 88
7.5.8 Groupe d’essais EP – Méthode de connexion . 89
7.5.9 Groupe d’essais FP – Transmission électrique . 89
7.5.10 Groupe d’essais GP – Impédance de transfert et affaiblissement de
couplage . 90
7.5.11 Groupe d’essais HP – Courant admissible . 90
Annexe A (informative) Orientation du détrompage . 91
A.1 Orientation du détrompage M17 . 91
A.2 Orientation du détrompage M23 . 91
A.3 Orientation du détrompage M40 . 92
Bibliographie . 93

Figure 1 – Embase, contacts mâles ou femelles, version à sortie droite, montage avant
par bride carrée . 19
Figure 2 – Embase, contacts mâles ou femelles, version à sortie droite, méthode de
montage par écrou, avec ou sans orientation de montage . 20
Figure 3 – Embase, contacts mâles ou femelles, version à sortie coudée,montage
avant par bride carrée . 21
Figure 4 – Embase, contacts mâles ou femelles, version à sortie coudée, méthode de
montage par écrou . 22
Figure 5 – Connecteur démontable, contacts mâles ou femelles, version à sortie droite. 24
Figure 6 – Connecteur non démontable, contacts mâles ou femelles, version à sortie
droite . 25
Figure 7 – Connecteur démontable, contacts mâles ou femelles, version à sortie droite. 25
Figure 8 – Connecteur non démontable, contacts mâles ou femelles, version à sortie
droite . 26
Figure 9 – Dimensions d’accouplement M12 pour le détrompage de type 1 pour
connecteurs mâles . 27
Figure 10 – Dimensions d’accouplement M12 pour le détrompage de type 2 pour
connecteurs mâles . 28
Figure 11 – Dimensions d’accouplement M12 pour le détrompage de type 3 et le
modèle avec des contacts mâles . 30
Figure 12 – Dimensions d’accouplement M12 pour les connecteurs femelles (sur
l’exemple de détrompage de type 1/2) . 32
Figure 13 – Dimensions d’accouplement M12 pour les embases (vue de côté) . 33
Figure 14 – Dimensions communes pour les connecteurs mâles M17 de type 1/1A/1B . 34
Figure 15 – Dimensions détaillées pour les connecteurs mâles M17 de type 1/1A/1B . 35
Figure 16 – Dimensions communes pour les connecteurs mâles M17 de type 2/2A/2B . 36
Figure 17 – Dimensions détaillées pour les connecteurs mâles M17 de type 2/2A/2B . 37
Figure 18 – Dimensions des broches pour les connecteurs mâles M17 de
type 1/1A/1B/2/2A/2B . 38
Figure 19 – Dimensions d’accouplement M17 pour l’embase (vue de côté) . 39
Figure 20 – Dimensions communes pour les connecteurs mâles M23 de type 1/1A . 40
Figure 21 – Dimensions détaillées pour connecteur mâle M23 de type 1/1A. 41
Figure 22 – Dimensions communes pour les connecteurs mâles M23 de type 2/2A . 42
Figure 23 – Dimensions détaillées pour connecteur mâle M23 de type 2/2A. 43
Figure 24 – Dimensions des broches pour les connecteurs mâles M23 de
type 1/1A/2/2A . 44
Figure 25 – Dimensions d’accouplement M23 pour l’embase (vue de côté) . 46
Figure 26 – Dimensions communes pour les connecteurs mâles M40 de type 1/1A . 47
Figure 27 – Dimensions détaillées pour les connecteurs mâles M40 de type 1/1A. 48
Figure 28 – Dimensions communes pour les connecteurs mâles M40 de type 2/2A . 49
Figure 29 – Dimensions détaillées pour les connecteurs mâles M40 de type 2/2A. 50
Figure 30 – Dimensions des broches pour les connecteurs mâles M40 de
type 1/1A/2/2A . 51
Figure 31 – Dimensions d’accouplement M40 pour les embases (vue de côté) . 53
Figure 32 – Variantes d’accouplement . 55
Figure 33 – Dimensions du calibre . 59
Figure 34 – Affectations des éléments de contact, vues de face, M12, de type 1 . 60
Figure 35 – Affectations des éléments de contact, vues de face, M12, de type 2 . 60
Figure 36 – Affectations des éléments de contact, vues de face, M12, de type 3 . 61
Figure 37 – Affectations des éléments de contact, vues de face, M17, de type 1/1A . 61
Figure 38 – Affectations des éléments de contact, vues de face, M17, de type 1B . 62
Figure 39 – Affectations des éléments de contact, vues de face, M17, de type 2/2A . 62
Figure 40 – Affectations des éléments de contact, vues de face, M17, de type 2B . 63
Figure 41 – Affectations des éléments de contact, vues de face, M23, de type 1/1A . 64
Figure 42 – Affectations des éléments de contact, vues de face, M23, de type 2/2A . 64
Figure 43 – Affectations des éléments de contact, vues de face, M40, de type 1/1A . 65
Figure 44 – Affectations des éléments de contact, vues de face, M40, de type 2/2A . 66
Figure 45 – Montage pour l’essai de la résistance de contact . 80
Figure 46 – Montage pour les essais de vibrations et de chocs mécaniques . 81
Figure A.1 – Exemple d’orientation pour les sorties M17 coudées vers le bas . 91
Figure A.2 – Exemple d’orientation pour les sorties M23 coudées vers le bas . 91
Figure A.3 – Exemple d’orientation pour les sorties M40 coudées vers le bas . 92

Tableau 1 – Détrompage. 14
Tableau 2 – Modèles d’embases . 18
Tableau 3 – Dimensions des modèles Mxx_DM et Mxx_DF Figure 1 . 20
Tableau 4 – Dimensions des modèles Mxx_EM, Mxx_EF, Mxx_GM et Mxx_GF,
Figure 2 . 21
Tableau 5 – Dimensions des modèles Mxx_DM90 et Mxx_DF90, Figure 3 . 22
Tableau 6 – Dimensions des modèles Mxx_EM90 et Mxx_EF90, Figure 4 . 23
Tableau 7 – Modèles de fiches . 23
Tableau 8 – Dimensions des modèles Mxx_JM et Mxx_JF, Figure 5 . 24
Tableau 9 – Dimensions des modèles Mxx_LM et Mxx_LF, Figure 6 . 25
Tableau 10 – Dimensions des modèles Mxx_JM et Mxx_JF, Figure 7 . 26
Tableau 11 – Dimensions pour les modèles Mxx_LMC et Mxx_LFC, Figure 8 . 26
Tableau 12 – Dimensions pour la Figure 9, la Figure 10 et la Figure 11 . 29
Tableau 13 – Dimensions pour la Figure 9, la Figure 10 et la Figure 11 . 31
Tableau 14 – Dimensions pour la Figure 12 . 32
Tableau 15 – Dimensions pour la Figure 13 . 33
Tableau 16 – Dimensions pour la Figure 14 . 34
Tableau 17 – Dimensions pour la Figure 15 . 35
Tableau 18 – Dimensions pour la Figure 16 . 36
Tableau 19 – Dimensions pour la Figure 17 . 37
Tableau 20 – Dimensions pour la Figure 18 . 38
Tableau 21 – Dimensions pour la Figure 19 . 39
Tableau 22 – Dimensions pour la Figure 20 . 40
Tableau 23 – Dimensions pour la Figure 21 . 41
Tableau 24 – Dimensions pour la Figure 22 . 42
Tableau 25 – Dimensions pour la Figure 23 . 43
Tableau 26 – Dimensions pour la Figure 24 . 45
Tableau 27 – Dimensions pour la Figure 25 . 46
Tableau 28 – Dimensions pour la Figure 26 . 47
Tableau 29 – Dimensions pour la Figure 27 . 48
Tableau 30 – Dimensions pour la Figure 28 . 49
Tableau 31 – Dimensions pour la Figure 29 . 50
Tableau 32 – Dimensions pour la Figure 30 . 52
Tableau 33 – Dimensions pour la Figure 31 . 54
Tableau 34 – Dimensions des connecteurs en position accouplée et verrouillée . 56
Tableau 35 – Calibres . 59
Tableau 36 – Affectations des éléments de contact M12 . 61
Tableau 37 – Affectations des éléments de contact M17 . 63
Tableau 38 – Affectations des éléments de contact M23 . 65
Tableau 39 – Affectations des éléments de contact M40 . 66
Tableau 40 – Tailles des broches . 67
Tableau 41 – Catégorie climatique . 67
Tableau 42 – Tension assignée . 68
Tableau 43 – Tension de tenue . 69
Tableau 44 – Courant assigné des connecteurs . 70
Tableau 45 – Résistance de contact maximale. 70
Tableau 46 – Résistance maximale entre entrée et sortie en courant continu . 71
Tableau 47 – Résistance maximale entre entrée et sortie en courant continu, en
régime déséquilibré . 71
Tableau 48 – Résistance d’isolement minimale . 71
Tableau 49 – Exigences relatives à la perte d’insertion . 72
Tableau 50 – Exigences relatives à l’affaiblissement de réflexion . 72
Tableau 51 – Exigences relatives à la paradiaphonie . 73
Tableau 52 – Exigences relatives à la télédiaphonie . 73
Tableau 53 – Exigences relatives à la perte de conversion transverse . 73
Tableau 54 – Exigences relatives à la perte de transfert de conversion transverse . 74
Tableau 55 – Exigences relatives à l’impédance de transfert . 74
Tableau 56 – Exigences relatives à l’affaiblissement de couplage . 75
Tableau 57 – Exigences relatives à la puissance cumulée de paradiaphonie exogène . 75
Tableau 58 – Exigences relatives à la puissance cumulée de paradiaphonie exogène . 76
Tableau 59 – Exigences relatives au temps de propagation . 76
Tableau 60 – Nombre de cycles de manœuvres mécaniques . 77
Tableau 61 – Forces minimales pour le mécanisme de verrouillage rapide . 77
Tableau 62 – Forces d’insertion et d’extraction . 78
Tableau 63 – Force d’insertion du détrompage . 78
Tableau 64 – Sévérités pour les chocs et vibrations (sinusoïdales) . 79
Tableau 65 – Nombre de spécimens d’essai et de contacts . 82
Tableau 66 – Groupe d’essais P . 82
Tableau 67 – Groupe d’essais AP . 83
Tableau 68 – Groupe d’essais BP . 85
Tableau 69 – Groupe d’essais CP . 87
Tableau 70 – Groupe d’essais DP . 88
Tableau 71 – Groupe d’essais EP . 89
Tableau 72 – Groupe d’essais FP . 89
Tableau 73 – Groupe d’essais GP. 90
Tableau 74 – Groupe d’essais HP . 90

COMMISSION ÉLECTROTECHNIQUE INTERNATIONALE
____________
Connecteurs pour équipements électriques et électroniques -
Exigences de produit -
Partie 2-117: Spécification particulière pour les fiches et embases
écrantées et non écrantées M12 à M40 pour la transmission de puissance,
auxiliaire et de données à des fréquences jusqu’à 600 MHz

AVANT-PROPOS
1) La Commission Électrotechnique Internationale (IEC) est une organisation mondiale de normalisation composée
de l’ensemble des comités électrotechniques nationaux (Comités nationaux de l’IEC). L’IEC a pour objet de
favoriser la coopération internationale pour toutes les questions de normalisation dans les domaines de
l’électricité et de l’électronique. À cet effet, l’IEC – entre autres activités – publie des Normes internationales,
des Spécifications techniques, des Rapports techniques, des Spécifications accessibles au public (PAS) et des
Guides (ci-après dénommés "Publication(s) de l’IEC"). Leur élaboration est confiée à des comités d’études, aux
travaux desquels tout Comité national intéressé par le sujet traité peut participer. Les organisations
internationales, gouvernementales et non gouvernementales, en liaison avec l’IEC, participent également aux
travaux. L’IEC collabore étroitement avec l’Organisation Internationale de Normalisation (ISO), selon des
conditions fixées par accord entre les deux organisations.
2) Les décisions ou accords officiels de l’IEC concernant les questions techniques représentent, dans la mesure du
possible, un accord international sur les sujets étudiés, étant donné que les Comités nationaux de l’IEC intéressés
sont représentés dans chaque comité d’études.
3) Les Publications de l’IEC se présentent sous la forme de recommandations internationales et sont agréées
comme telles par les Comités nationaux de l’IEC. Tous les efforts raisonnables sont entrepris afin que l’IEC
s’assure de l’exactitude du contenu technique de ses publications; l’IEC ne peut pas être tenue responsable de
l’éventuelle mauvaise utilisation ou interprétation qui en est faite par un quelconque utilisateur final.
4) Dans le but d’encourager l’uniformité internationale, les Comités nationaux de l’IEC s’engagent, dans toute la
mesure possible, à appliquer de façon transparente les Publications de l’IEC dans leurs publications nationales
et régionales. Toutes divergences entre toutes Publications de l’IEC et toutes publications nationales ou
régionales correspondantes doivent être indiquées en termes clairs dans ces dernières.
5) L’IEC elle-même ne fournit aucune attestation de conformité. Des organismes de certification indépendants
fournissent des services d’évaluation de conformité et, dans certains secteurs, accèdent aux marques de
conformité de l’IEC. L’IEC n’est responsable d’aucun des services effectués par les organismes de certification
indépendants.
6) Tous les utilisateurs doivent s’assurer qu’ils sont en possession de la dernière édition de cette publication.
7) Aucune responsabilité ne doit être imputée à l’IEC, à ses administrateurs, employés, auxiliaires ou mandataires,
y compris ses experts particuliers et les membres de ses comités d’études et des Comités nationaux de l’IEC,
pour tout préjudice causé en cas de dommages corporels et matériels, ou de tout autre dommage de quelque
nature que ce soit, directe ou indirecte, ou pour supporter les coûts (y compris les frais de justice) et les dépenses
découlant de la publication ou de l’utilisation de cette Publication de l’IEC ou de toute autre Publication de l’IEC,
ou au crédit qui lui est accordé.
8) L’attention est attirée sur les références normatives citées dans cette publication. L’utilisation de publications
référencées est obligatoire pour une application correcte de la présente publication.
9) L’IEC attire l’attention sur le fait que la mise en application du présent document peut entraîner l’utilisation d’un
ou de plusieurs brevets. L’IEC ne prend pas position quant à la preuve, à la validité et à l’applicabilité de tout
droit de brevet revendiqué à cet égard. À la date de publication du présent document, l’IEC [avait/n’avait pas]
reçu notification qu’un ou plusieurs brevets pouvaient être nécessaires à sa mise en application. Toutefois, il y a
lieu d’avertir les responsables de la mise en application du présent document que des informations plus récentes
sont susceptibles de figurer dans la base de données de brevets, disponible à l’adresse https://patents.iec.ch.
L’IEC ne saurait être tenue pour responsable de ne pas avoir identifié de tels droits de brevet.
L’IEC 61076-2-117 a été établie par le sous-comité 48B: Connecteurs électriques, du comité
d’études 48 de l’IEC: Connecteurs électriques et structures mécaniques pour les équipements
électriques et électroniques. Il s’agit d’une Norme internationale.
Le texte de cette Norme internationale est issu des documents suivants:
Projet Rapport de vote
48B/3208/FDIS 48B/3222/RVD
Le rapport de vote indiqué dans le tableau ci-dessus donne toute information sur le vote ayant
abouti à son approbation.
La langue employée pour l’élaboration de cette Norme internationale est l’anglais.
Ce document a été rédigé selon les Directives ISO/IEC, Partie 2, il a été développé selon les
Directives ISO/IEC, Partie 1 et les Directives ISO/IEC, Supplément IEC, disponibles sous
www.iec.ch/members_experts/refdocs. Les principaux types de documents développés par
l’IEC sont décrits plus en détail sous www.iec.ch/publications.
Une liste de toutes les parties de la série IEC 61076, publiées sous le titre général Connecteurs
pour équipements électriques et électroniques – Exigences de produit, se trouve sur le site web
de l’IEC.
Le comité a décidé que le contenu de ce document ne sera pas modifié avant la date de stabilité
indiquée sur le site web de l’IEC sous webstore.iec.ch dans les données relatives au document
recherché. À cette date, le document sera
– reconduit,
– supprimé, ou
– révisé.
INTRODUCTION
IEC SC 48B – Connecteurs électriques IEC 61076-2-117 Éd. 1
Spécification disponible auprès de:
Secrétariat général de l’IEC ou aux adresses
figurant à l’intérieur de la couverture.
SPÉCIFICATION PARTICULIÈRE conformément à
l’IEC 61076-2
Connecteurs circulaires écrantés et non écrantés (étant
donné que l’ensemble des connecteurs décrits dans le
présent document sont équipés de parties écrantées
dédiées à la transmission de données, les termes
"écranté" et "non écranté" font respectivement
référence à la présence ou à l’absence d’un corps de
connecteur écranté) destinés à des applications
d’alimentation, auxiliaires et de données, avec
verrouillage à vis M12, M17, M23 et M40 et verrouillage
rapide.
Alimentation
jusqu’à 600 V en courant alternatif/continu et jusqu’à
70 A
Auxiliaire
jusqu’à 50 V en courant alternatif/continu et jusqu’à
30 A
Données
jusqu’à 600 MHz
Contacts mâles et femelles
Démontables
Non démontables
Embases démontables avec contacts mâles ou
femelles, accouplables avec des fiches à vis Mxx ou à
verrouillage rapide.
Fiches pour câble
Embases:
Embases à sortie droite
Embases à sortie coudée
Montage à bride
Montage sur panneau par écrou
1 Domaine d’application
La présente partie de l’IEC 61076-2 couvre les fiches et embases circulaires écrantées et non
écrantées sans pouvoir de coupure (COC) pour la transmission de puissance, de signaux et de
données et spécifie respectivement les dimensions communes, les caractéristiques
mécaniques, électriques et de transmission, les exigences environnementales, ainsi que les
spécifications d’essai.
NOTE 1 Étant donné que l’ensemble des connecteurs décrits dans le présent document sont équipés de parties
écrantées dédiées à la transmission de données, les termes "écranté" et "non écranté" font respectivement référence
à la présence ou à l’absence d’un corps de connecteur écranté.
Les connecteurs décrits dans le présent document sont équipés d’un mécanisme de
verrouillage à vis M12, M17, M23 ou M40 ou d’un mécanisme de verrouillage rapide dont la
taille dépend des vis utilisées. Il peut s’agir d’embases démontables avec contacts mâles ou
femelles, accouplables avec des fiches à vis Mxx ou à verrouillage rapide.
Le présent document fournit plusieurs interfaces d’accouplement dont chacune est associée à
un détrompage empêchant l’accouplement de connecteurs mâles et femelles incompatibles.
Les différents détrompages diffèrent par leur nombre de voies, la disposition et l’épaisseur des
broches, et, de ce fait, par leurs capacités de transmission de puissance et de données. Ces
détrompages sont appelés "type x", où "x" représente un nombre arabe.
Les connecteurs décrits dans le présent document sont destinés à être utilisés dans les
applications d’automatisation à un seul câble qui exigent différentes combinaisons et différents
niveaux de puissance jusqu’à 600 V en courant alternatif/continu et jusqu’à 70 A, ainsi que la
transmission de signaux ou de données, ou les deux, à des fréquences jusqu’à 600 MHz.
NOTE 2 Les exigences (ou informations) décrites dans le présent document facilitent la transmission de données
par l’intermédiaire des systèmes de support Ethernet suivants, tels que définis dans l’IEEE 802.3:
– ethernet à paire unique (10BASE-T1, 100BASE-T1, 1000BASE-T1),
– Ethernet rapide (100BASE-TX),
– Ethernet gigabit (1000BASE-T),
– Ethernet 10 gigabits (10GBASE-T).
2 Références normatives
Les documents suivants sont cités dans le texte de sorte qu’ils constituent, pour tout ou partie
de leur contenu, des exigences du présent document. Pour les références datées, seule
l’édition citée s’applique. Pour les références non datées, la dernière édition du document de
référence s’applique (y compris les éventuels amendements).
IEC 60050-581, Vocabulaire Électrotechnique International - Chapitre 581: Composants
électromécaniques pour équipements électroniques
IEC 60068-1, Essais d’environnement - Partie 1: Généralités et lignes directrices
IEC 60068-2-60, Essais d’environnement - Partie 2-60: Essais - Essai Ke: Essai de corrosion
dans un flux de mélange de gaz
IEC 60352 (toutes les parties), Connexions sans soudure
IEC 60512-1, Connecteurs pour équipements électriques et électroniques - Essais et mesures -
Partie 1: Spécification générique
IEC 60512-1-1, Connecteurs pour équipements électroniques - Essais et mesures - Partie 1-1:
Examen général - Essai 1a: Examen visuel
IEC 60512-1-2, Connecteurs pour équipements électroniques - Essais et mesures - Partie 1-2:
Examen général - Essai 1b: Examen de dimension et masse
IEC 60512-2-1, Connecteurs pour équipements électroniques - Essais et mesures - Partie 2-1:
Essais de continuité électrique et de résistance de contact - Essai 2a: Résistance de contact -
Méthode du niveau des millivolts
IEC 60512-2-5, Connecteurs pour équipements électroniques - Essais et mesures - Partie 2-5:
Essais de continuité électrique et de résistance de contact - Essai 2e: Perturbation de contact
IEC 60512-3-1, Connecteurs pour équipements électroniques - Essais et mesures - Partie-3-1:
Essais d’isolement - Essai 3a: Résistance d’isolement
IEC 60512-4-1, Connecteurs pour équipements électroniques - Essais et mesures - Partie 4-1:
Essais de contrainte diélectrique - Essai 4a: Tension de tenue
IEC 60512-5-2, Connecteurs pour équipements électroniques - Essais et mesures - Partie 5-2:
Essais de courant limite - Essai 5b: Taux de réduction de l’intensité en fonction de la
température
IEC 60512-6-3, Connecteurs pour équipements électroniques - Essais et mesures - Partie 6-3:
Essais de contraintes dynamiques - Essai 6c: Chocs
IEC 60512-6-4, Connecteurs pour équipements électroniques - Essais et mesures - Partie 6-4:
Essais de contraintes dynamiques - Essai 6d: Vibrations (sinusoïdales)
IEC 60512-9-1, Connecteurs pour équipements électroniques - Essais et mesures - Partie 9-1:
Essais d’endurance - Essai 9a: Fonctionnement mécanique
IEC 60512-9-2, Connecteurs pour équipements électroniques - Essais et mesures - Partie 9-2:
Essais d’endurance - Essai 9b: Charge électrique et température
IEC 60512-11-1, Connecteurs pour équipements électriques et électroniques - Essais et
mesures - Partie 11: Essais climatiques - Essai 11a - Séquence climatique
IEC 60512-11-4, Connecteurs pour équipements électroniques - Essais et mesures -
Partie 11-4: Essais climatiques - Essai 11d: Variations rapides de température
IEC 60512-11-7, Connecteurs pour équipements électroniques - Essais et mesures -
Partie 11-7: Essais climatiques - Essai 11g: Essai de corrosion dans un flux de mélange de gaz
IEC 60512-11-9, Connecteurs pour équipements électroniques - Essais et mesures -
Partie 11-9: Essais climatiques - Essai 11i: Chaleur sèche
IEC 60512-11-10, Connecteurs pour équipements électroniques - Essais et mesures -
Partie 11-10: Essais climatiques - Essai 11j: Froid
IEC 60512-11-12, Connecteurs pour équipements électroniques - Essais et mesures -
Partie 11-12: Essais climatiques - Essai 11m: Essai cyclique de chaleur humide
IEC 60512-13-2, Connecteurs pour équipements électroniques - Essais et mesures -
Partie 13-2: Essais de fonctionnement mécanique - Essai 13b: Forces d’insertion et d’extraction
IEC 60512-13-5, Connecteurs pour équipements électroniques - Essais et mesures -
Partie 13-5: Essais de fonctionnement mécanique - Essai 13e: Méthode de polarisation et de
codage
IEC 60512-15-6, Connecteurs pour équipements électroniques - Essais et mesures -
Partie 15-6: Essais (mécaniques) des connecteurs - Essai 15f: Efficacité des dispositifs
d’accouplement des connecteurs
IEC 60512-16-5, Connecteurs pour équipements électroniques – Essais et mesures -
Partie 16-5: Essais mécaniques des contacts et des sorties - Essai 16e: Force de rétention du
calibre (contacts élastiques)
IEC 60512-19-3, Composants électromécaniques pour équipements électroniques -
Procédures d’essai de base et méthodes de mesure - Partie 19: Essais de résistance chimique -
Section 3: Essai 19c - Résistance aux fluides
IEC 60512-25-9, Connecteurs pour équipements électroniques - Essais et mesures -
Partie 25-9: Essais d’intégrité des signaux - Essai 25i: Diaphonie exogène
IEC 60512-26-100, Connecteurs pour équipements électroniques - Essais et mesures -
Partie 26-100: Montage de mesure, dispositifs d’essai et de référence et mesures pour les
connecteurs conformes à la CEI 60603-7 - Essais 26a à 26g
IEC 60512-29-100, Connecteurs pour équipements électroniques - Essais et mesures -
Partie 29-100: Essais d’intégrité des signaux jusqu’à 500 MHz sur les connecteurs de type
M12 - Essais 29a à 29g
IEC 60529:1989, Degrés de protection procurés par les enveloppes (Code IP)
...