Ventilation for buildings - Design criteria for the indoor environment
This European Prestandard specifies the requirements for, and methods of expressing the quality of the indoor environment for the design, commissioning, operation and control of ventilation and air-conditioning systems. For the purposes of this prestandard, the indoor environment comprises the thermal environment, the air quality and the acoustic environment. This prestandard covers indoor environments where the major concern is the human occupation but excludes dwellings.
Prezračevanje zgradb - Merila za projektiranje notranjega okolja
General Information
Standards Content (Sample)
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Ventilation for buildings - Design criteria for the indoor environment91.140.30VLVWHPLVentilation and air-conditioningICS:Ta slovenski standard je istoveten z:CR 1752:1998SIST CR 1752:1999en01-september-1999SIST CR 1752:1999SLOVENSKI
STANDARD
SIST CR 17
...
This May Also Interest You
This document specifies general requirements and gives guidelines for ventilation systems except for industrial, medical and laboratory facilities.
This document also specifies cleanliness criteria and procedures necessary in assessing and maintaining the cleanliness of ventilation systems over their lifetime from design and installation to maintenance.
This document is applicable to both new and existing ventilation systems with, and without, air conditioning and kitchen extract systems.
- Standard44 pagesEnglish languagesale 10% offe-Library read for×1 day
- 22-Jul-2025
- 91.140.30
- CEN/TC 156
This document specifies laboratory test methods, test requirements and classifications for the casings of non-residential air handling units (AHU). For the leakage tests, a method for on-site testing is also included.
The test methods and requirements are applicable to both model boxes and real units, except for the thermal and acoustic performance of the casing.
The test method for the thermal performance of the casing is applicable to the comparison of different casing constructions, but not for the calculation of thermal losses through casing or the risk of condensation.
The test method for the acoustic performance of the casing is applicable for the comparison of different constructions, but not for the provision of accurate acoustic data for specific units.
This document is not applicable for fan-coil units and similar products.
The filter bypass test specified in this document is not applicable to high efficiency particulate air (HEPA) filter installations.
- Standard56 pagesEnglish languagesale 10% offe-Library read for×1 day
- 24-Jun-2025
- 91.140.30
- CEN/TC 156
This document applies to the design, energy performance of buildings and implementation of ventilation, air conditioning and room conditioning systems for non-residential buildings subject to human occupancy, excluding applications like industrial processes. It focuses on the definitions of the various parameters that are relevant for such systems.
The guidance for design given in this document and accompanying CEN/TR 16798-4 are mainly applicable to mechanical supply and/or exhaust ventilation systems. Natural ventilation systems or natural parts of hybrid ventilation systems are not covered by this document.
Applications for residential ventilation are not covered in this document. Performance of ventilation systems in residential buildings is covered in EN 15665 and CEN/TR 14788.
The classification uses different categories. For some values, examples are given and, for requirements, typical ranges with default values are presented. The default values are given in Annex B and a template for national specification is given in Annex A. It is important that the classification is always appropriate to the type of building and its intended use, and that the basis of the classification is explained if the examples given in this document are not used.
NOTE 1 Different standards can express the categories for the same parameters in a different way, and also the category symbols can be different.
Table 1 shows the relative position of this document within the set of EPB standards in the context of the modular structure as set out in EN ISO 52000-1.
NOTE 2 In CEN ISO/TR 52000-2 the same Table can be found, with, for each module, the numbers of the relevant EPB standards and accompanying technical reports that are published or in preparation.
NOTE 3 The modules represent EPB standards, although one EPB standard might cover more than one module and one module might be covered by more than one EPB standard, for instance a simplified and a detailed method respectively. See also Clause 2 and Table A.1 and Table B.1.
Table 1 - Position of this standard (in case M5-1, M5-4), within the modular structure of the set of EPB standards
- Standard82 pagesEnglish languagesale 10% offe-Library read for×1 day
- 29-Apr-2025
- 91.120.10
- 91.140.30
- 2010/31/EU
- M/480
- CEN/TC 156
This document specifies methods for the measurement of air flow rates on site. It provides a description of the air flow rate measurement methods and how measurements are performed within the margins of stipulated method uncertainties. It gives the necessary measurement conditions (e.g. length of straight duct, uniform velocity profile) to achieve the stipulated measurement uncertainties.
The methods for measuring the air flow rate inside ducts do not apply to:
- ducts that are not circular or rectangular (e.g. oblong ducts);
- flexible ducts.
- Standard62 pagesEnglish languagesale 10% offe-Library read for×1 day
- 12-Nov-2024
- 17.120.10
- 91.140.30
- CEN/TC 156
This document specifies methods for the testing and rating of dampers and valves used in air distribution systems with pressure differences up to 2 000 Pa.
The tests incorporated in this document will address:
- leakage past a closed damper or valve (for classification, see Annex C);
- casing leakage (for classification, see Annex C);
- flow rate/pressure requirement characteristics;
- torque: (see Annex A);
- thermal transmittance: (see Annex B).
The tests specified above are applicable to the following:
- measurement of leakage past a closed damper or valve;
- measurement of casing leakage;
- determination of flow rate and pressure requirements;
- measurement of torque characteristics (see Annex A);
- measurement of thermal transfer characteristics to determine insulation properties (see Annex B).
This document does not apply to the acoustic testing of dampers and valves.
NOTE Certain aspects of the dynamic performance of dampers and/or valves are dependent upon the air distribution system to which they are connected and are, therefore, difficult to measure in isolation. Such considerations have led to the omission of these aspects of the dynamic performance measurements from this document. Also, in common with other air distribution components, the results from tests carried out in accordance with this document might not be directly applicable if the damper or valve is situated in an area of non-uniform flow.
- Standard30 pagesEnglish languagesale 10% offe-Library read for×1 day
- 21-May-2024
- 91.140.30
- CEN/TC 156
This document specifies the laboratory test methods and test requirements for the testing of aerodynamic, thermal, acoustic and the electrical performance characteristics of non-ducted mechanical supply and exhaust residential ventilation units used in single dwellings.
The purpose of this document is not to consider the quality of ventilation but to test the performance of the equipment.
This document is applicable to ventilation units, the latter:
a) containing either:
- fans for mechanical supply and exhaust;
- air filters;
- air-to-air heat exchanger for heat and possibly humidity recovery;
- control system;
- inlet and outlet grilles; or
- alternating heat exchangers which provide separate supply and exhaust air flows;
b) provided either:
- in one assembly; or
- in more than one assembly, the separate assemblies of which are designed to be used together.
This document does not deal with ducted units which are covered by EN 13141-7 or units with heat pumps.
Safety requirements are given in EN 60335-2-40 and EN 60335-2-80.
- Standard58 pagesEnglish languagesale 10% offe-Library read for×1 day
- 06-Sep-2022
- 91.140.30
- CEN/TC 156
This document specifies and classifies the component/product performance characteristics, which may be necessary for the design, rating and dimensioning, placing on the market of residential ventilation products and systems to provide the predetermined performance, comfort conditions of temperature, air velocity, humidity, hygiene and sound in the occupied zone.
It defines those performance characteristics (mandatory or optional) which shall be determined, measured and presented according to relevant test methods. It provides a classification scheme, which leads to a full definition of product properties based on test methods described in various EN Standards, and gives an overview of the test standards. Distinction between mandatory and optional requirement is left to each European and national regulations.
The codification part in Annex B and the classification part in Clause 8 apply to the following products:
- unidirectional mechanical supply and exhaust residential ventilation units according to EN 13141-4:2021, EN 13141-6:2014 and EN 13141-11;
- ducted mechanical bidirectional residential ventilation units according to EN 13141-7:2021;
- non-ducted mechanical bidirectional residential ventilation units according to prEN 13141 8:2020.
This document does not apply to other products such as filters, fire dampers, ducts, control devices and sound attenuators, which may also be incorporated in residential ventilation.
This European Standard specifies in Annex ZA and Annex ZB the requirements of EU 1253/2014 and EU 1254/2014 for residential ventilation units below 1 000 m3/h air volume flow.
This European Standard does not cover requirements raised by European Directives (e.g. low voltage directive, EMC directive) and other requirements such as corrosion, reaction to fire and snow penetration.
- Standard97 pagesEnglish languagesale 10% offe-Library read for×1 day
- Standard97 pagesEnglish languagesale 10% offe-Library read for×1 day
- 13-Apr-2021
- 30-Oct-2021
- 91.140.30
- 1253/2014
- 1254/2014
- M/537
- CEN/TC 156
This document specifies the laboratory test methods and test requirements for the testing of aerodynamic, thermal, acoustic and electrical performance characteristics of ducted mechanical supply and exhaust residential ventilation units.
NOTE Such units are referred to as bidirectional ventilation units in EN 13142:2021.
This document is applicable to unit that contain at least, within one or more casing:
- fans for mechanical supply and exhaust;
- air filters;
- air-to-air heat exchanger and/or air-to-air heat pump for air heat recovery;
- control system.
Such unit can be provided in more than one assembly, the separate assemblies of which are designed to be used together.
Examples of different possible arrangements of heat recovery, heat exchangers and/or heat pumps are described in Annex A.
This document covers ventilation units with continuous mass flows for each setting point.
This document does not deal with non-ducted units that are treated in prEN 13141-8:2021.
This document does not cover ventilation systems that may also provide water space heating and hot water that are treated in EN 16573.
This document does not cover units including combustion engine driven compression heat pumps and absorption heat pumps.
Electrical safety requirements are given in EN 60335-2-40 and EN 60335-2-80.
- Standard54 pagesEnglish languagesale 10% offe-Library read for×1 day
- 13-Apr-2021
- 30-Oct-2021
- 91.140.30
- CEN/TC 156
This document specifies aerodynamic, acoustic and electrical power performance test methods for unidirectional ventilation units used in residential ventilation systems.
This document is applicable to ventilation units:
- installed on a wall or in a window without any duct, A category;
- installed in the upstream of a duct, B category;
- installed in the downstream of a duct, C category;
- installed in a duct, or with duct connection upstream and downstream, D category;
- with one or several inlets/outlets;
- installed in a system with a heat pump for domestic hot water or water for cooling or heating;
- which can be used for supply or exhaust.
This document does not apply to:
- fan assisted cowls which are tested according to EN 13141-5;
- mechanical supply and exhaust units which are tested according to EN 13141-7:2021 or EN 13141 8:2021.
- Standard44 pagesEnglish languagesale 10% offe-Library read for×1 day
- 13-Apr-2021
- 30-Oct-2021
- 91.140.30
- CEN/TC 156
This document specifies methods for measuring:
- the aerodynamic characteristics of cowls, fan assisted cowls and roof outlets;
- the electrical and acoustic characteristics of fan assisted cowls.
This document is applicable to cowls, assisted cowls and roof outlets used in natural, hybrid or mechanical ventilation and that are meant to be fitted onto ducts which project above the roof surface.
This document does not apply to:
- assisted cowls assisted by a device other than a fan (e.g. injection assisted cowls);
- roof exhaust fans (see EN 13141-4).
- Standard29 pagesEnglish languagesale 10% offe-Library read for×1 day
- Standard29 pagesEnglish languagesale 10% offe-Library read for×1 day
- 27-Oct-2020
- 29-Apr-2021
- 91.140.30
- 305/2011
- CEN/TC 156
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.