Distribution automation using distribution line carrier systems -- Part 3: Mains signaling requirements -- Section 21: MV phase-to-phase isolated capacitive coupling device

Establishes definitions, requirements, methods of testing and rated values for phase-to-phase isolated capacitive coupling devices to be used in medium-voltage (MV) distribution line carrier systems.

Verteilungsautomatisierung mit Hilfe von Trägersystemen auf Verteilungsleitungen -- Teil 3: Netzbedingte Anforderungen an die Signalübertragung -- Hauptabschnitt 21: Kapazitiv getrennte Außenleiter-Außenleiter-Ankopplungseinrichtungen für Mittelspannung

Automatisation de la distribution à l'aide de systèmes de communication à courants porteurs -- Partie 3: Prescriptions concernant la transmission des signaux sur le secteur -- Section 21: Dispositif de couplage phase-phase capacitif isolé MT

Etablit des définitions, des prescriptions, des méthodes d'essais et spécifie des valeurs nominales pour les dispositifs de couplage capacitifs phase-phase isolés sur des systèmes DLC moyenne tension.

Distribution automation using distribution line carrier systems - Part 3: Mains signalling requirements - Section 21: MV phase-to-phase isolated capacitive coupling device

General Information

Status
Published
Publication Date
31-Jul-1997
Technical Committee
PSE - Power systems management
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
01-Aug-1997
Due Date
01-Aug-1997
Completion Date
01-Aug-1997

Buy Documents

Standard

SIST EN 61334-3-21:1997

English language (20 pages)
Preview
Preview
e-Library read for
1 day

Relations

Effective Date
03-Feb-2026
Effective Date
03-Feb-2026
Effective Date
03-Feb-2026

Overview

SIST EN 61334-3-21:1997 is a Slovenian standard addressing key requirements for distribution automation using distribution line carrier systems. Specifically, this standard defines the terminology, requirements, test methods, and rated values for phase-to-phase isolated capacitive coupling devices intended for use in medium-voltage (MV) distribution line carrier systems. These devices play a critical role in facilitating mains signaling within MV power distribution networks, ensuring reliable and standardized communication infrastructure for automation purposes.

Key Topics

The standard covers several important aspects related to MV phase-to-phase isolated capacitive coupling devices:

  • Definitions: Establishes clear and uniform terminology for all relevant components and functions.
  • General Requirements: Outlines criteria related to design, installation, and operational safety.
  • Rated Values: Specifies the electrical parameters and performance ratings for capacitive coupling devices.
  • Methods of Testing: Details standardized testing procedures to verify compliance and functionality of the devices.
  • Isolation Requirements: Provides guidance on the necessary isolation characteristics between phase conductors for safe and effective operation.
  • Application in Distribution Line Carrier Systems: Ensures that devices are suitable for integration into MV networks for reliable signal transmission.

Applications

This standard is especially relevant to professionals designing, installing, or maintaining medium-voltage distribution automation systems. Practical use cases include:

  • Distribution Automation: Enabling efficient and standardized communication between substations and control systems, improving fault detection and remote control capabilities.
  • Mains Signaling: Providing reliable carrier signal transmission for monitoring and controlling distribution network equipment.
  • Network Interfacing: Facilitating safe signal coupling between different phases in MV distribution networks.
  • Substation Equipment Integration: Supporting compatibility and interoperability between transformers, switchgear, and communication modules.

By following the specified requirements and test methods, utilities and manufacturers ensure devices offer consistent performance, electrical safety, and compatibility with existing systems.

Related Standards

The SIST EN 61334-3-21:1997 standard is part of the broader EN 61334 series which defines standards for distribution automation using distribution line carrier systems. Related standards may include:

  • EN 61334-1: General overview and requirements for distribution line carrier systems.
  • EN 61334-2: Communication protocols and data transmission methods.
  • EN 61334-3: Specific technical requirements for main signaling equipment and associated coupling devices.
  • IEC 60044 Series: Instrument transformers relevant to power system measurement.
  • Local and European MV network standards: For installation, safety, and operation of medium-voltage equipment.

Summary

Adhering to SIST EN 61334-3-21:1997 provides a standardized approach to implementing phase-to-phase isolated capacitive coupling devices within medium-voltage distribution automation systems. Ensuring compliance enhances safety, interoperability, and network reliability, supporting the growing demands for efficient distribution automation and smart grid infrastructure. For organizations committed to high-quality MV distribution line carrier communication, this standard is an essential reference.

Buy Documents

Standard

SIST EN 61334-3-21:1997

English language (20 pages)
Preview
Preview
e-Library read for
1 day

Get Certified

Connect with accredited certification bodies for this standard

ANCE

Mexican certification and testing association.

EMA Mexico Verified

Intertek Slovenia

Intertek testing, inspection, and certification services in Slovenia.

UKAS Slovenia Verified

LNE (Laboratoire National de Métrologie et d'Essais)

French national laboratory for metrology and testing.

COFRAC France Verified

Sponsored listings

Frequently Asked Questions

SIST EN 61334-3-21:1997 is a standard published by the Slovenian Institute for Standardization (SIST). Its full title is "Distribution automation using distribution line carrier systems -- Part 3: Mains signaling requirements -- Section 21: MV phase-to-phase isolated capacitive coupling device". This standard covers: Establishes definitions, requirements, methods of testing and rated values for phase-to-phase isolated capacitive coupling devices to be used in medium-voltage (MV) distribution line carrier systems.

Establishes definitions, requirements, methods of testing and rated values for phase-to-phase isolated capacitive coupling devices to be used in medium-voltage (MV) distribution line carrier systems.

SIST EN 61334-3-21:1997 is classified under the following ICS (International Classification for Standards) categories: 33.040.50 - Lines, connections and circuits. The ICS classification helps identify the subject area and facilitates finding related standards.

SIST EN 61334-3-21:1997 has the following relationships with other standards: It is inter standard links to SIST HD 472 S1:1996, SIST EN 60071-1:2001, SIST EN 60721-1:2001. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

SIST EN 61334-3-21:1997 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)


SLOVENSKI STANDARD
01-avgust-1997
Distribution automation using distribution line carrier systems - Part 3: Mains
signalling requirements - Section 21: MV phase-to-phase isolated capacitive
coupling device
Distribution automation using distribution line carrier systems -- Part 3: Mains signaling
requirements -- Section 21: MV phase-to-phase isolated capacitive coupling device
Verteilungsautomatisierung mit Hilfe von Trägersystemen auf Verteilungsleitungen -- Teil
3: Netzbedingte Anforderungen an die Signalübertragung -- Hauptabschnitt 21: Kapazitiv
getrennte Außenleiter-Außenleiter-Ankopplungseinrichtungen für Mittelspannung
Automatisation de la distribution à l'aide de systèmes de communication à courants
porteurs -- Partie 3: Prescriptions concernant la transmission des signaux sur le secteur -
- Section 21: Dispositif de couplage phase-phase capacitif isolé MT
Ta slovenski standard je istoveten z: EN 61334-3-21:1996
ICS:
33.040.50 Vodi, zveze in tokokrogi Lines, connections and
circuits
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
...