Alarm systems - Intrusion and hold-up systems -- Part 2-7-2: Intrusion detectors - Glass break detectors (passive)

This European standard is for passive surface mounted glass break detectors installed in buildings and provides for security Grades 1 to 4 (see EN 50131-1), specific or non-specific wired or wire-free detectors, and uses environmental classes I to IV (see EN 50130-5). This European standard does not include requirements for passive surface mounted glass break detectors intended for use outdoors. A detector shall fulfil all the requirements of the specified Grade. Functions additional to the mandatory functions specified in this standard may be included in the detector, providing they do not adversely influence the correct operation of the mandatory functions. This European standard does not apply to system interconnections.

Alarmanlagen - Einbruch- und Überfallmeldeanlagen -- Teil 2-7-2: Einbruchmelder - Glasbruchmelder (Passiv)

Systèmes d’alarme - Systèmes d'alarme contre l’intrusion et les hold-up -- Partie 2-7-2: Détecteurs d'intrusion - Détecteurs bris de glace (passifs)

La présente Norme Européenne concerne les détecteurs de bris de glace passifs montés en surface installés dans les bâtiments, décrit les détecteurs câblés ou sans fil spécifiques ou non des Grades de protection 1 à 4 (voir l'EN 50131-1) et utilise les classes d’environnement I à IV (voir l'EN 50130-5). Elle ne traite pas des exigences des détecteurs de bris de glace passifs montés en surface destinés à une utilisation à l'extérieur. Un détecteur doit satisfaire à toutes les exigences du Grade spécifié. Des fonctions supplémentaires aux fonctions obligatoires spécifiées dans la présente norme peuvent être incluses dans le détecteur, à condition qu'elles ne nuisent pas au bon fonctionnement des fonctions obligatoires. La présente Norme Européenne ne s'applique pas aux interconnexions de systèmes.

Alarmni sistemi - Sistemi za javljanje vloma in ropa - 2-7-2. del: Zahteve za javljalnike vloma - Javljalniki loma stekla (pasivni) - Dopolnilo IS1

Ta evropski standard se uporablja za pasivne javljalnike loma stekla, nameščene na površino zgradb, določa varnostne razrede od 1 do 4 in lastnosti specifičnih in nespecifičnih kabelskih ali brezžičnih javljalnikov ter uporablja okoljske razrede od I do IV. Ta evropski standard ne vključuje zahtev za pasivne javljalnike loma stekla, nameščene na površino, ki so namenjeni za uporabo na prostem. Javljalnik mora izpolnjevati vse zahteve posameznega razreda. Poleg obveznih funkcij, ki so opredeljene v tem standardu, ima lahko javljalnik tudi dodatne funkcije, pri čemer te ne smejo negativno vplivati na pravilno delovanje obveznih funkcij. Ta evropski standard se ne uporablja za medsebojne povezave sistemov.

General Information

Status
Published
Publication Date
11-Mar-2014
Technical Committee
EAL - Alarm systems
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
10-Mar-2014
Due Date
15-May-2014
Completion Date
12-Mar-2014

Buy Documents

Addendum

SIST EN 50131-2-7-2:2012/IS1:2014

English language (6 pages)
Preview
Preview
e-Library read for
1 day

Relations

Effective Date
09-Feb-2026
Effective Date
01-Apr-2014

Overview

SIST EN 50131-2-7-2:2012/IS1:2014 is a Slovenian (SIST) adoption of the European standard EN 50131-2-7-2:2012/IS1:2014, dedicated to alarm systems for intrusion and hold-up protection. Specifically, this standard addresses the requirements for passive surface mounted glass break detectors installed indoors within buildings. These detectors form a critical element of comprehensive intrusion detection systems, offering enhanced security against unauthorized access by detecting the breakage of glass.

This standard applies to both wired and wireless (wire-free) detectors and covers security Grades 1 through 4, as established in EN 50131-1, which define the varying levels of risk and required robustness for intrusion alarm systems. Environmental classes I to IV from EN 50130-5 are also referenced, offering guidelines for adapting systems to a range of building environments. This document does not cover detectors intended for outdoor use or system interconnections.

Key Topics

  • Security Grades: The standard supports four grades, allowing for the correct specification of glass break detectors according to the assessed risk level of the premises.
  • Detector Types: Covers requirements for both specific and non-specific, wired, and wire-free passive glass break detectors.
  • Environmental Classes: Refers to four environmental classes (I-IV), ensuring the suitability of detectors for different environmental conditions inside buildings.
  • Test Procedures: Specifies guidance for reproducible test methods, including the use of specified test magnets for interference testing.
  • Interpretation Sheet: The included IS1:2014 interpretation clarifies acceptable testing materials and procedures for manufacturers and test houses to ensure consistent and reliable results.
  • Functionality Compliance: All detectors must fulfill mandatory functions specified for the applicable grade; optional features are permitted if they do not interfere with these core functions.

Applications

Passive glass break detectors compliant with SIST EN 50131-2-7-2:2012/IS1:2014 are widely used in the following scenarios:

  • Commercial Buildings: Protecting office spaces, retail stores, and public buildings against forced entry through windows or glass doors.
  • Residential Security: Enhancing home security systems by detecting potential break-ins via glass windows or patio doors.
  • Banking and Finance: Integrating into high-security alarm systems where robust intrusion detection is crucial for asset protection.
  • Museums and Galleries: Added security for premises with valuable and fragile displays, especially where glass casings are used.
  • Adaptable Installation: Suitable for diverse indoor building environments, aligning the environmental class to specific conditions such as temperature, humidity, and pollution levels.

The standard’s adoption ensures compatibility, reliability, and efficiency of glass break detectors within broader alarm and intrusion detection systems, supporting risk assessment-based deployment and regulatory compliance.

Related Standards

For comprehensive compliance and effective system integration, the following related standards are relevant:

  • EN 50131-1: Intrusion and hold-up alarm systems - System requirements; defines security grades and system design principles.
  • EN 50130-5: Alarm systems - Part 5: Environmental test methods; describes environmental classes for installation locations.
  • EN 60404-5: Magnetic materials - Permanent magnet materials – Methods of measurement of magnetic properties; referenced for test magnet specifications.
  • EN 60404-14: Magnetic materials - Methods for measuring magnetic dipole moment; forms basis for required magnet calibration.

In conclusion, SIST EN 50131-2-7-2:2012/IS1:2014 is an essential specification for manufacturers, integrators, and specifiers of intrusion and alarm systems, ensuring that passive glass break detectors deliver reliable security performance for indoor applications, comply with European standards, and address a range of security requirements.

Buy Documents

Addendum

SIST EN 50131-2-7-2:2012/IS1:2014

English language (6 pages)
Preview
Preview
e-Library read for
1 day

Get Certified

Connect with accredited certification bodies for this standard

CIS Institut d.o.o.

Personal Protective Equipment (PPE) certification body. Notified Body NB-2890 for EU Regulation 2016/425 PPE.

SA Slovenia Verified

Kiwa BDA Testing

Building and construction product certification.

RVA Netherlands Verified

Kmetijski inštitut Slovenije

Agricultural Institute of Slovenia. Soil testing, plant health, agricultural product analysis.

SA Slovenia Verified

Sponsored listings

Frequently Asked Questions

SIST EN 50131-2-7-2:2012/IS1:2014 is a addendum published by the Slovenian Institute for Standardization (SIST). Its full title is "Alarm systems - Intrusion and hold-up systems -- Part 2-7-2: Intrusion detectors - Glass break detectors (passive)". This standard covers: This European standard is for passive surface mounted glass break detectors installed in buildings and provides for security Grades 1 to 4 (see EN 50131-1), specific or non-specific wired or wire-free detectors, and uses environmental classes I to IV (see EN 50130-5). This European standard does not include requirements for passive surface mounted glass break detectors intended for use outdoors. A detector shall fulfil all the requirements of the specified Grade. Functions additional to the mandatory functions specified in this standard may be included in the detector, providing they do not adversely influence the correct operation of the mandatory functions. This European standard does not apply to system interconnections.

This European standard is for passive surface mounted glass break detectors installed in buildings and provides for security Grades 1 to 4 (see EN 50131-1), specific or non-specific wired or wire-free detectors, and uses environmental classes I to IV (see EN 50130-5). This European standard does not include requirements for passive surface mounted glass break detectors intended for use outdoors. A detector shall fulfil all the requirements of the specified Grade. Functions additional to the mandatory functions specified in this standard may be included in the detector, providing they do not adversely influence the correct operation of the mandatory functions. This European standard does not apply to system interconnections.

SIST EN 50131-2-7-2:2012/IS1:2014 is classified under the following ICS (International Classification for Standards) categories: 13.310 - Protection against crime; 13.320 - Alarm and warning systems. The ICS classification helps identify the subject area and facilitates finding related standards.

SIST EN 50131-2-7-2:2012/IS1:2014 has the following relationships with other standards: It is inter standard links to SIST EN 15999-2:2025, SIST EN 50131-2-7-2:2012. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

SIST EN 50131-2-7-2:2012/IS1:2014 is associated with the following European legislation: EU Directives/Regulations: 2012-01-0929, 2020-01-0063. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.

SIST EN 50131-2-7-2:2012/IS1:2014 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)


SLOVENSKI STANDARD
01-april-2014
Alarmni sistemi - Sistemi za javljanje vloma in ropa - 2-7-2. del: Zahteve za
javljalnike vloma - Javljalniki loma stekla (pasivni) - Dopolnilo IS1
Alarm systems - Intrusion and hold-up systems -- Part 2-7-2: Intrusion detectors - Glass
break detectors (passive)
Alarmanlagen - Einbruch- und Überfallmeldeanlagen -- Teil 2-7-2: Einbruchmelder -
Glasbruchmelder (Passiv)
Systèmes d’alarme - Systèmes d'alarme contre l’intrusion et les hold-up -- Partie 2-7-2:
Détecteurs d'intrusion - Détecteurs bris de glace (passifs)
Ta slovenski standard je istoveten z: EN 50131-2-7-2:2012/IS1:2014
ICS:
13.310 Varstvo pred kriminalom Protection against crime
13.320 Alarmni in opozorilni sistemi Alarm and warning systems
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

INTERPRETATION SHEET
EN 50131-2-7-2/IS1
FEUILLE D'INTERPRETATION
February 2014
INTERPRETATIONSBLATT
ICS 13.320
English version
Alarm systems -
Intrusion and hold-up systems -
Part 2-7-2: Intrusion detectors -
Glass break detectors (passive)

Systèmes d’alarme -  Alarmanlagen -
Systèmes d'alarme contre l’intrusion et les Einbruch- und Überfallmeldeanlagen -
hold-up - Teil 2-7-2: Einbruchmelder -
Partie 2-7-2: Détecteurs d'intrusion - Glasbruchmelder (Passiv)
Détecteurs bris de glace (passifs)

This European Standard was approved by CENELEC on 2013-12-23. CENELEC members are bound to comply
with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard
the status of a national standard without any alteration.

Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the CEN-CENELEC Management Centre or to any CENELEC member.

This European Standard exists in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CENELEC member into its own language and notified
to the CEN-CENELEC Management Centre has the same status as the official versions.

CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus,
the Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany,
Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland,
Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom.

CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung

CEN-CENELEC Management Centre: Avenue Marnix 17, B - 1000 Brussels

© 2014 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 50131-2-7-2:2012/IS1:2014 E

Contents Page
Foreword . 3
Clause: . 4
Question: . 4
Interpretation: . 4
Validity: .
...