oSIST prEN 12259-12:2005
(Main)Fixed firefighting systems - Components for sprinkler and water spray systems - Part 12: Pumps
Fixed firefighting systems - Components for sprinkler and water spray systems - Part 12: Pumps
These guidelines describe requirements and test methods for the approval of sprinkler pumps. The type approval testing of sprinkler pumps can be carried out at the manufacturers site. Sprinkler pumps include centralfugal pumps used to deliver water in fixed sprinkler, water spray and foam systems. They are started up only in the event of fire and for periodic testing purposes. The basic requirements for sprinkler pumps shall be that they are constantly ready for use at all times and shall operate reliably.
Ortsfeste Löschanlagen - Bauteile für Sprinkler- und Sprühwasseranlagen - Teil 12: Sprinklerpumpen
Diese Norm legt Anforderungen und Prüfverfahren für die Anerkennung von Sprinklerpumpen fest. Die Typenprüfung für die Anerkennung von Sprinklerpumpen kann im Herstellerwerk durchgeführt werden. Sprinklerpumpen beinhalten Zentrifugalpumpen für die Förderung oder Lieferung von Wasser in ortsfesten Sprinkler-, Sprühwasser- und Schaumlöschanlagen. Sie werden nur im Brandfalle und für periodische Prüfungen in Betrieb genommen. Grundlegende Anforderungen an Sprinklerpumpen sind die konstante Bereitschaft für einen jederzeitigen Einsatz sowie die zuverlässige Funktion.
Installations fixes de lutte contre l'incendie - Composants des systemes d'extinction du type sprinkleur et a pulvérisation d'eau - Partie 12: Pompe pour sprinkleurs
Vgrajene naprave za gašenje – Sestavni deli sprinklerskih sistemov in sistemov s pršečo vodo – 12. del: Črpalke
General Information
- Status
- Not Published
- Technical Committee
- POZ - Požarna varnost
- Current Stage
- 98 - Abandoned project (Adopted Project)
- Start Date
- 03-Apr-2024
- Due Date
- 08-Apr-2024
- Completion Date
- 03-Apr-2024
- Directive
- Harmonized Standard305/2011 - Regulation (eu) No 305/2011 of the European Parliament and of the Council of 9 march 2011 laying down harmonised conditions for the marketing of construction products and repealing council directive 89/106/eec
Not Harmonized89/106/EEC - Construction products
Overview
oSIST prEN 12259-12:2005 sets out comprehensive requirements for pumps used in fixed firefighting systems, specifically for sprinkler and water spray systems. Developed by the Slovenian Institute for Standardization (SIST), this standard outlines key criteria and test methods for the approval and reliable operation of centrifugal pumps-vital components for ensuring continuous fire protection in diverse facilities.
The provisions aim to guarantee that sprinkler pumps are always operational, starting automatically during fire events or periodic maintenance tests. By establishing clear guidelines, the standard supports manufacturers, installers, and authorities in maintaining the effectiveness and safety of fixed firefighting systems.
Key Topics
- Performance Requirements
The standard defines the essential performance characteristics for pumps in firefighting systems, emphasizing continuous readiness and dependable functionality during emergencies. - Type Approval Testing
Procedures for testing sprinkler pumps are specified, allowing for approval at the manufacturer’s site. Tests validate pump functionality under various conditions representative of actual fire scenarios. - Application Scope
Covers centrifugal pumps intended for use with sprinkler, water spray, and foam systems. The standard applies to pumps that start automatically upon fire detection and during scheduled operational checks. - Reliability and Maintenance
Guidelines enforce continuous operability and require regular testing to ensure pumps perform as intended whenever needed.
Applications
Sprinkler Pumps in Fire Safety:
Pumps conforming to oSIST prEN 12259-12:2005 are crucial across multiple sectors:
- Commercial and Industrial Facilities: Protect factories, warehouses, and business premises with reliable water delivery for fire suppression.
- Residential Buildings: Provide safety to multi-occupancy structures by ensuring immediate water flow during fire events.
- Public Infrastructure: Enhance fire protection in schools, hospitals, airports, and transport hubs where uninterrupted sprinkler operation is critical.
Integration with Fire Protection Systems:
This standard applies to pumps in:
- Fixed sprinkler systems,
- Water spray systems for high-risk areas,
- Foam-based systems for hazardous materials.
By specifying test methods and performance criteria, the standard helps ensure pump interoperability and regulatory compliance, ultimately safeguarding property and lives.
Related Standards
For a holistic approach to designing and maintaining fire protection systems, consider referencing:
- oSIST EN 12259-1: Fixed firefighting systems - Components for sprinkler and water spray systems - Part 1: Sprinklers
- EN 12845: Fixed firefighting systems – Automatic sprinkler systems – Design, installation, and maintenance
- ISO 6182 Series: International standards for components and systems in fire suppression
- EN 671: Fixed firefighting systems – Hose systems
Compliance with oSIST prEN 12259-12:2005, alongside related standards, strengthens fire safety protocols and supports consistent, high-quality fire protection across industries.
Keywords: sprinkler pump standard, fixed firefighting systems, water spray system pumps, centrifugal fire pump requirements, fire safety standard, SIST standards, pump approval testing, sprinkler system components.
Get Certified
Connect with accredited certification bodies for this standard
CIS Institut d.o.o.
Personal Protective Equipment (PPE) certification body. Notified Body NB-2890 for EU Regulation 2016/425 PPE.

Kiwa BDA Testing
Building and construction product certification.
Kmetijski inštitut Slovenije
Agricultural Institute of Slovenia. Soil testing, plant health, agricultural product analysis.
Sponsored listings
Frequently Asked Questions
oSIST prEN 12259-12:2005 is a draft published by the Slovenian Institute for Standardization (SIST). Its full title is "Fixed firefighting systems - Components for sprinkler and water spray systems - Part 12: Pumps". This standard covers: These guidelines describe requirements and test methods for the approval of sprinkler pumps. The type approval testing of sprinkler pumps can be carried out at the manufacturers site. Sprinkler pumps include centralfugal pumps used to deliver water in fixed sprinkler, water spray and foam systems. They are started up only in the event of fire and for periodic testing purposes. The basic requirements for sprinkler pumps shall be that they are constantly ready for use at all times and shall operate reliably.
These guidelines describe requirements and test methods for the approval of sprinkler pumps. The type approval testing of sprinkler pumps can be carried out at the manufacturers site. Sprinkler pumps include centralfugal pumps used to deliver water in fixed sprinkler, water spray and foam systems. They are started up only in the event of fire and for periodic testing purposes. The basic requirements for sprinkler pumps shall be that they are constantly ready for use at all times and shall operate reliably.
oSIST prEN 12259-12:2005 is classified under the following ICS (International Classification for Standards) categories: 13.220.10 - Fire-fighting. The ICS classification helps identify the subject area and facilitates finding related standards.
oSIST prEN 12259-12:2005 is associated with the following European legislation: EU Directives/Regulations: 305/2011, 89/106/EEC; Standardization Mandates: M/109. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.
oSIST prEN 12259-12:2005 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
SLOVENSKI STANDARD
01-junij-2005
9JUDMHQHQDSUDYH]DJDãHQMH±6HVWDYQLGHOLVSULQNOHUVNLKVLVWHPRYLQVLVWHPRYV
SUãHþRYRGR±GHOýUSDONH
Fixed firefighting systems - Components for sprinkler and water spray systems - Part 12:
Pumps
Ortsfeste Löschanlagen - Bauteile für Sprinkler- und Sprühwasseranlagen - Teil 12:
Sprinklerpumpen
Installations fixes de lutte contre l'incendie - Composants des systemes d'extinction du
type sprinkleur et a pulvérisation d'eau - Partie 12: Pompe pour sprinkleurs
Ta slovenski standard je istoveten z: prEN 12259-12
ICS:
13.220.10 Gašenje požara Fire-fighting
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
oSIST p
...