SIST EN 50525-3-41:2011
Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 3-41: Cables with special fire performance - Single core non-sheathed cables with halogen-free crosslinked insulation, and low emission of smoke
Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 3-41: Cables with special fire performance - Single core non-sheathed cables with halogen-free crosslinked insulation, and low emission of smoke
EN 50525-3-41 applies to non-sheathed single core cables insulated with halogen-free crosslinked compound and having low emission of smoke and corrosive gases when exposed to fire. NOTE 1 Low emission of smoke is checked in accordance with EN 61034-2. Low emission of corrosive gases is checked as part of the check for absence of halogens (see Annex B of EN 50525-1). The cables are of rated voltages U0/U up to and including 450/750 V. NOTE 2 Cables rated 450/750 V may be used at 600/1 000 V when this cable is used in fixed installations with mechanical protection, within switchgear and control gear - see HD 516. The cables are intended for fixed wiring applications. The maximum conductor operating temperature for each of the cables in this standard is 90 °C. NOTE 3 HD 516 contains extensive guidance on the safe use of cables in this standard. This EN 50525-3-41 should be read in conjunction with EN 50525-1, which specifies general requirements.
Kabel und Leitungen - Starkstromleitungen mit Nennspannungen bis 450/750 V (U0/U) - Teil 3-41: Leitungen mit verbessertem Verhalten im Brandfall - Halogenfreie, raucharme Ader- und Verdrahtungsleitungen mit vernetzter Isolierung
Câbles électriques - Câbles d’énergie basse tension de tension assignée au plus égale à 450/750 V (U0/U) - Partie 3-41: Câbles à performances spéciales au feu - Conducteurs isolés en matériau élastomère réticulé sans halogène, à faible dégagement de fumée
Električni kabli - Nizkonapetostni energetski kabli z nazivno napetostjo do vključno 450/750 V (U0/U) - 3-41. del: Kabli s posebnimi ognjevarnimi lastnostmi - Enožilni neoplaščeni kabli z zamreženo izolacijo brez halogenov in z nizko emisijo dima
EN 50525-2-41 velja za enožilne kable z zamreženo izolacijo iz silikonske gume. Tipi, ki so vključeni, so ali samo izolirani ali izolirani in pleteni ali pa izolirani in oplaščeni. Ti kabli imajo nazivno napetost U0/U do vključno 300/500 V. Kabli se uporabljajo pri fiksnih inštalacijah na območjih z visokimi temperaturami. Maksimalna delovna temperatura pretvornika za vsakega od kablov iz tega standarda je 180 °C.
General Information
- Status
- Published
- Public Enquiry End Date
- 28-Feb-2009
- Publication Date
- 12-Jun-2011
- Technical Committee
- IEKA - Electric cables
- Current Stage
- 6060 - National Implementation/Publication (Adopted Project)
- Start Date
- 08-Jun-2011
- Due Date
- 13-Aug-2011
- Completion Date
- 13-Jun-2011
- Directive
- Not Harmonized2006/95/EC - Directive 2006/95/EC of the European Parliament and of the Council of 12 December 2006 on the harmonisation of the laws of Member States relating to electrical equipment designed for use within certain voltage limits (codified version)OJ Ref: C 348/03 OJ Date: 28-Nov-2013 Conflicting Date: 17-Jan-2014
Harmonized Standard2014/35/EU - Directive 2014/35/EU of the European Parliament and of the Council of 26 February 2014 on the harmonisation of the laws of the Member States relating to the making available on the market of electrical equipment designed for use within certain voltage limitsOJ Ref: C 249/03 OJ Date: 08-Jul-2016
Relations
- Effective Date
- 28-Jan-2023
- Effective Date
- 09-Feb-2026
- Effective Date
- 09-Feb-2026
- Effective Date
- 03-Feb-2026
- Effective Date
- 06-Jan-2009
Overview
SIST EN 50525-3-41:2011 specifies requirements for electric cables designed for low voltage energy distribution, with rated voltages up to and including 450/750 V (U0/U). This standard focuses on single core, non-sheathed cables insulated with a halogen-free, crosslinked compound that provides improved fire performance. These cables are engineered to emit low levels of smoke and corrosive gases when exposed to fire, reducing risks to people and sensitive equipment in case of fire incidents. The standard applies primarily to fixed wiring applications, providing guidance on the safe and effective deployment of these specialized electric cables.
Key Topics
- Low Voltage Energy Cables: The standard covers single core cables rated up to 450/750 V, suitable for residential, commercial, and industrial installations.
- Halogen-Free Crosslinked Insulation: Insulation is made of polyolefin cross-linked material, free from halogens, reducing the emission of toxic and corrosive gases during fire.
- Low Smoke Emission: The cables are tested for low smoke emission in accordance with EN 61034-2, ensuring that visibility and air quality are maintained during fire events.
- Fire Performance: Cables must meet stringent vertical flame propagation tests (EN 60332-1-2) and demonstrate low smoke and halogen emissions.
- Applications for Fixed Wiring: The products described are intended for fixed wiring, both for external and internal uses, and are capable of performing at a maximum conductor operating temperature of 90 °C.
- Types and Marking: The standard differentiates between cable types such as H07Z-U (class 1 core), H07Z-R (class 2 core), H07Z-K (class 5 core), H05Z-U, and H05Z-K, based on conductor flexibility and size.
Applications
Cables conforming to SIST EN 50525-3-41:2011 are widely used in electrical installations where enhanced safety against fire hazards is critical. Key applications include:
- Public Buildings: Schools, hospitals, shopping centers, airports, and other spaces with high occupancy, where safe evacuation is a priority.
- Industrial and Commercial Premises: Facilities with sensitive electronic equipment that can be damaged by corrosive gas emissions, such as data centers and production plants.
- Transport Infrastructure: Railways, tunnels, and underground stations, where fire safety and smoke reduction are crucial in confined spaces.
- Switchgear and Control Gear: When provided with adequate mechanical protection, these cables can be used for circuits with higher voltage ratings in fixed installations.
- Green Building Projects: The use of low smoke, halogen-free cables contributes to safer, more sustainable construction and improved indoor air quality.
Related Standards
To ensure comprehensive compliance and performance, SIST EN 50525-3-41:2011 should be used in conjunction with several important related standards:
- EN 50525-1: General requirements for low voltage energy cables.
- EN 61034-2: Measurement of smoke density of cables burning under defined conditions.
- EN 60332-1-2: Tests on electric and optical fibre cables under fire conditions.
- EN 50395 & EN 50396: Electrical and non-electrical test methods for low voltage energy cables.
- EN 60228: Conductors of insulated cables.
- EN 50363-5: Halogen-free, cross-linked insulating compounds.
- HD 516: Guidance on the use of low voltage harmonized cables.
By specifying halogen-free insulation and low smoke emission properties, SIST EN 50525-3-41:2011 supports the installation of safer, more reliable electrical systems in modern buildings and infrastructure, meeting both safety regulations and market demands for environmentally responsible materials. This standard plays a vital role in reducing fire risks and minimizing health hazards associated with cable fires in populated or sensitive environments.
Get Certified
Connect with accredited certification bodies for this standard

IMQ S.p.A. (Certification)
Italian electrical product certification.

SLG Prüf- und Zertifizierungs GmbH
German testing and certification body.

UL Solutions
Global safety science company with testing, inspection and certification.
Sponsored listings
Frequently Asked Questions
SIST EN 50525-3-41:2011 is a standard published by the Slovenian Institute for Standardization (SIST). Its full title is "Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 3-41: Cables with special fire performance - Single core non-sheathed cables with halogen-free crosslinked insulation, and low emission of smoke". This standard covers: EN 50525-3-41 applies to non-sheathed single core cables insulated with halogen-free crosslinked compound and having low emission of smoke and corrosive gases when exposed to fire. NOTE 1 Low emission of smoke is checked in accordance with EN 61034-2. Low emission of corrosive gases is checked as part of the check for absence of halogens (see Annex B of EN 50525-1). The cables are of rated voltages U0/U up to and including 450/750 V. NOTE 2 Cables rated 450/750 V may be used at 600/1 000 V when this cable is used in fixed installations with mechanical protection, within switchgear and control gear - see HD 516. The cables are intended for fixed wiring applications. The maximum conductor operating temperature for each of the cables in this standard is 90 °C. NOTE 3 HD 516 contains extensive guidance on the safe use of cables in this standard. This EN 50525-3-41 should be read in conjunction with EN 50525-1, which specifies general requirements.
EN 50525-3-41 applies to non-sheathed single core cables insulated with halogen-free crosslinked compound and having low emission of smoke and corrosive gases when exposed to fire. NOTE 1 Low emission of smoke is checked in accordance with EN 61034-2. Low emission of corrosive gases is checked as part of the check for absence of halogens (see Annex B of EN 50525-1). The cables are of rated voltages U0/U up to and including 450/750 V. NOTE 2 Cables rated 450/750 V may be used at 600/1 000 V when this cable is used in fixed installations with mechanical protection, within switchgear and control gear - see HD 516. The cables are intended for fixed wiring applications. The maximum conductor operating temperature for each of the cables in this standard is 90 °C. NOTE 3 HD 516 contains extensive guidance on the safe use of cables in this standard. This EN 50525-3-41 should be read in conjunction with EN 50525-1, which specifies general requirements.
SIST EN 50525-3-41:2011 is classified under the following ICS (International Classification for Standards) categories: 29.060.20 - Cables. The ICS classification helps identify the subject area and facilitates finding related standards.
SIST EN 50525-3-41:2011 has the following relationships with other standards: It is inter standard links to SIST HD 22.9 S3:2007, SIST EN 1648-1:2018, SIST EN 1648-2:2018, SIST EN 60335-1:2012/A13:2017, SIST HD 22.9 S3:2007. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
SIST EN 50525-3-41:2011 is associated with the following European legislation: EU Directives/Regulations: 2006/95/EC, 2014/35/EU. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.
SIST EN 50525-3-41:2011 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
SLOVENSKI STANDARD
01-september-2011
(OHNWULþQLNDEOL1L]NRQDSHWRVWQLHQHUJHWVNLNDEOL]QD]LYQRQDSHWRVWMRGR
YNOMXþQR988GHO.DEOLVSRVHEQLPLRJQMHYDUQLPLODVWQRVWPL
(QRåLOQLQHRSODãþHQLNDEOL]]DPUHåHQRL]RODFLMREUH]KDORJHQRYLQ]QL]NRHPLVLMR
GLPD
Electric cables - Low voltage energy cables of rated voltages up to and including 450/750
V (U0/U) - Part 3-41: Cables with special fire performance - Single core non-sheathed
cables with halogen-free crosslinked insulation, and low emission of smoke
Kabel und Leitungen - Starkstromleitungen mit Nennspannungen bis 450/750 V (U0/U) -
Teil 3-41: Leitungen mit verbessertem Verhalten im Brandfall - Halogenfreie, raucharme
Ader- und Verdrahtungsleitungen mit vernetzter Isolierung
Câbles électriques - Câbles d’énergie basse tension de tension assignée au plus égale à
450/750 V (U0/U) - Partie 3-41: Câbles à performances spéciales au feu - Conducteurs
isolés en matériau élastomère réticulé sans halogène, à faible dégagement de fumée
Ta slovenski standard je istoveten z: EN 50525-3-41:2011
ICS:
29.060.20 Kabli Cables
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
EUROPEAN STANDARD
EN 50525-3-41
NORME EUROPÉENNE
May 2011
EUROPÄISCHE NORM
ICS 29.060.20 Supersedes HD 22.9 S3:2007
English version
Electric cables -
Low voltage energy cables of rated voltages up to and including 450/750 V
(U /U) -
Part 3-41: Cables with special fire performance -
Single core non-sheathed cables with halogen-free crosslinked insulation,
and low emission of smoke
Câbles électriques - Kabel und Leitungen -
Câbles d’énergie basse tension de tension Starkstromleitungen mit Nennspannungen
assignée au plus égale à 450/750 V bis 450/750 V (U /U) -
(U /U) - Teil 3-41: Starkstromleitungen mit
Partie 3-41: Câbles à performances verbessertem Verhalten im Brandfall -
spéciales au feu - Halogenfreie, raucharme Ader- und
Conducteurs isolés en matériau Verdrahtungsleitungen mit vernetzter
élastomère réticulé sans halogène, à Isolierung
faible dégagement de fumée
This European Standard was approved by CENELEC on 2011-01-17. CENELEC members are bound to comply
with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard
the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the Central Secretariat or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CENELEC member into its own language and notified
to the Central Secretariat has the same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus,
the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy,
Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia,
Spain, Sweden, Switzerland and the United Kingdom.
CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
Management Centre: Avenue Marnix 17, B - 1000 Brussels
© 2011 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 50525-3-41:2011 E
Foreword
This European Standard was prepared by the Technical Committee CENELEC TC 20, Electric
cables.
The text of the draft was submitted to the formal vote and was approved by CENELEC as
EN 50525-3-41 on 2011-01-17.
This document, which is one of a multipart series, supersedes HD 22.9 S3:2007.
Attention is drawn to the possibility that some of the elements of this document may be the
subject of patent rights. CEN and CENELEC shall not be held responsible for identifying any
or all such patent rights.
The following dates were fixed:
– latest date by which the EN has to be implemented
at national level by publication of an identical
national standard or by endorsement (dop) 2012-01-17
– latest date by which the national standards conflicting
with the EN have to be withdrawn (dow) 2014-01-17
____________
- 3 - EN 50525-3-41:2011
Contents
Page
1 Scope . 4
2 Normative references . 4
3 Terms and definitions . 5
4 Heat resistant cables (90 °C) . 5
4.1 Cables for fixed wiring – H07Z-U and H07Z-R . 5
4.2 Cables for fixed wiring – H07Z-K . 5
4.3 Cables for internal wiring – H05Z-U . 6
4.4 Cables for internal wiring – H05Z-K . 7
Annex A (normative) Tests for cables to EN 50525-3-41 . 8
Annex B (normative) General data . 9
Bibliography . 11
Tables
Table A.1 . 8
Table B.1 − Cables with rigid conductor (450/750 V) . 9
Table B.2 − Cables with flexible conductor (450/750 V) . 10
Table B.3 − Cables with rigid conductor (300/500 V) . 10
Table B.4 − Cables with flexible conductor (300/500 V) . 10
1 Scope
EN 50525-3-41 applies to non-sheathed single core cables insulated with halogen-free
crosslinked compound and having low emission of smoke and corrosive gases when exposed
to fire.
NOTE 1 Low emission of smoke is checked in accordance with EN 61034-2. Low emission of corrosive gases is checked as
part of the check for absence of halogens (see Annex B of EN 50525-1).
The cables are of rated voltages U /U up to and including 450/750 V.
NOTE 2 Cables rated 450/750 V may be used at 600/1 000 V when this cable is used in fixed installations with
mechanical protection, within switchgear and control gear - see HD 516.
The cables are intended for fixed wiring applications.
The maximum conductor operating temperature for each of the cables in this standard is
90 °C.
NOTE 3 HD 516 contains extensive guidance on the safe use of cables in this standard.
This EN 50525-3-41 should be read in conjunction with EN 50525-1, which specifies general
requirements.
2 Normative references
The following referenced documents are indispensable for the application of this document.
For dated references, only the edition cited applies. For undated references, the latest edition
of the referenced document (including any amendments) applies.
NOTE One or more references to the standards below are in respect of a specific sub-division of that standard,
for instance a clause, a table, a class or a type. Cross-references to these standards are undated and, at all times,
the latest version applies.
EN 50363-5 Insulating, sheathing and covering materials for low voltage
energy cables - Part 5: Halogen-free, cross-linked insulating
compounds
EN 50395 Electrical test methods for low voltage energy cables
EN 50396 Non electrical test methods for low voltage energy cables
EN 50525-1 Electric cables - Low voltage energy cables of rated voltages up
to and including 450/750 V (U /U) - Part 1: General requirements
EN 60228 Conductors of insulated cables (IEC 60228)
EN 60332-1-2 Tests on electric and optical fibre cables under fire conditions -
Part 1-2: Test for vertical flame propagation for a single insulated
wire or cable - Procedure for 1 kW pre-mixed flame
(IEC 60332-1-2)
EN 60811-1-4 Insulating and sheathing materials of electric and optical cables -
Common test methods - Part 1-4: General application - Test
...