IEC 60708:2005/COR1:2016
(Corrigendum)Corrigendum 1 - Low-frequency cables with polyolefin insulation and moisture barrier polyolefin sheath
Corrigendum 1 - Low-frequency cables with polyolefin insulation and moisture barrier polyolefin sheath
Corrigendum 1 - Câbles pour basses fréquences à isolation polyoléfine et gaine polyoléfine à barrière d'étanchéité
General Information
Relations
Standards Content (Sample)
IEC 2016
INTERNATIONAL ELECTROTECHNICAL COMMISSION
COMMISSION ÉLECTROTECHNIQUE INTERNATIONALE
____________
IEC 60708 IEC 60708
Edition 1.0 2005-06 Édition 1.0 2005-06
Low-frequency cables with polyolefin insulation Câbles pour basses fréquences à isolation
and moisture barrier polyolefin sheath polyoléfine et gaine polyoléfine à
barrière d'étanchéité
CO RRI G ENDU M 1
...
This May Also Interest You
is applicable to cables for inside installations, intended for the interconnection of the following: transmission equipment; telecommunications equipment; equipment for data processing.
- Standard21 pagesEnglish languagesale 15% off
is applicable to equipment wires with solid or stranded conductor, polyvinyl chloride (PVC) insulated, in singles, pairs and triples to be used for internal wiring of telecommunication equipment, industrial and consumer electronic equipment.
- Standard13 pagesEnglish languagesale 15% off
specifies mechanical, electrical and climatic test methods for low-frequency cables and wires designed for use in telecommunication inside plant and equipment and in electronic devices employing similar techniques.
- Standard17 pagesEnglish languagesale 15% off
IEC 60708:2005 is intended to define polyolefin insulated cables for insertion into local outdoor networks. Is applicable to polyolefin insulated and moisture barrier polyolefin sheathed telephone cables, filled or unfilled with copper conductors, includes general design details and requirements for dimensions and other constructional details as well as mechanical, electrical and environmental characteristics for all types of low-frequency cables with polyolefin insulation (solid or cellular), filled or unfilled, and moisture barrier polyolefin sheath (with integral suspension strand). The contents of the corrigendum of August 2016 have been included in this copy.
- Standard26 pagesEnglish languagesale 15% off
- Standard52 pagesEnglish and French languagesale 15% off
- Standard4 pagesEnglish languagesale 15% off
- Standard4 pagesFrench languagesale 15% off
- Standard7 pagesEnglish and French languagesale 15% off
IEC 60092-352:2025 provides the basic requirements for the selection, installation and operating conditions of electrical cables intended for fixed electrical systems on board ships at voltages (U) up to and including Um 18/30 (36) kV, symmetrical category cables and fibre optic cables.
The reference to fixed systems includes those that are subjected to vibration (due to the movement of the ship) or movement (due to motion of the ship) and not to those that are intended for frequent flexing.
Cables subject to frequent or continual flexing use, which can withstand the mechanical stress and the environment they are exposed to, are detailed in other IEC specifications such as IEC 60227 and IEC 60245. Flexible cables are frequently used for retractable thrusters, elevators, moving decks, cranes, shore connections and other moving applications on board ships.
This fourth edition cancels and replaces the third edition published in 2005. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) modification of the part title;
b) complete review of the document and establishment of the match with all other standards from the group IEC 60092-350 to IEC 60092-379;
c) addition of terms and definitions;
d) addition of technical requirements for the installation of symmetrical category cables with transmission characteristics up to 1 000 MHz;
e) addition of the technical requirements for the installation of fibre optic cables;
f) addition of technical requirements for the installation of cables for installation between areas with and without explosive atmospheres
- Standard115 pagesEnglish languagesale 15% off
- Standard1 pageEnglish languagesale 15% off
IEC 60332‑1‑2:2025 specifies the procedure for testing the resistance to vertical flame propagation for a single vertical electrical insulated conductor or cable, or optical fibre cable, under fire conditions using a 1 kW pre-mixed flame. The apparatus is described in IEC 60332‑1‑1.
NOTE 1 Testing to IEC 60332‑1‑2 can be performed simultaneously with that to IEC 60332‑1‑3, if required.
This group safety publication focusing on test method(s) is primarily intended to be used as a product safety standard for the products mentioned in the scope, but is also intended to be used by technical committees in the preparation of standards for products similar to those mentioned in the scope of this group safety publication, in accordance with the principles laid down in IEC Guide 104 and lSO/lEC Guide 51.
NOTE 2 The performing of this test method on a single insulated conductor or cable or optical fibre cable does not provide compliance with fire propagation requirements in relevant standards in the case that the single insulated conductor or cable or optical fibre cable is installed with or amongst other cables as a group. (See the IEC 60332‑3 series).
One of the responsibilities of a technical committee is, wherever applicable, to make use of basic safety publications and/or group safety publications in the preparation of its publications.
- Standard12 pagesEnglish languagesale 15% off
IEC 60331-4:2024 specifies the test apparatus and procedure, and gives the performance requirements, including recommended flame application times and flame temperatures, for power cables of rated voltage higher than 0,6/1,0 kV up to and including 18/30 kV for maintaining circuit integrity when subject to fire and mechanical shock under specified conditions.
The test method in this document is restricted to conductor sizes up to and including 120 mm2. The test results for 120 mm2 size conductors constructions qualify larger cross-sections of the same cable construction.
In the case of preassembled three-core cables, then the complete cable is considered as tested when a complete single-core of the cable has been tested.
This document includes details for the specific point of failure, continuity checking arrangement, test sample, test procedure and test report relevant to electric power cables with a rated voltage higher than 0,6/1,0 kV up to and including 18/30 kV.
Annex A provides the method of verification of the burner and control system used for the test.
Annex B provides a choice of the recommended test apparatus.
Annex C provides, as an option, guidance for using either water spray or water jet protocols.
Annex D provides, as an option, the flame temperature of 1 000 °C, which is applicable for special applications.
Requirements are stated for an identification that can optionally be marked on the cable to signify compliance with this document.
This group safety publication focusing on the test method for circuit integrity safety for power cables of rated voltage higher than 1 kV up to and including 30 kV under fire conditions, is primarily intended to be used as a product safety standard for the products mentioned in the scope, but is also intended to be used by TCs in the preparation of publications for products similar to those mentioned in the scope of this group safety publication, in accordance with the principles laid down in IEC Guide 104 and lSO/lEC Guide 51.
One of the responsibilities of a TC is, wherever applicable, to make use of either BSPs or GSPs, or both, in the preparation of its publications.
WARNING – The test given in this document can involve the use of dangerous voltages and temperatures. Suitable precautions should be taken against the risk of shock, burning, fire and explosion that can arise, and against any noxious fumes that can be produced.
- Standard29 pagesEnglish languagesale 15% off
IEC 60092-378:2024 is applicable to shipboard and offshore optical fibre cables, intended for fixed installations.
Cables designed to maintain functional integrity during fire given in 6.1 and to be installed in explosive atmospheres given in 6.2 are included.
The various types of optical fibre cables are given in Clause 6. The constructional requirements and test methods are aligned with those indicated in IEC 60092‑350, unless otherwise specified in this document.
- Standard19 pagesEnglish languagesale 15% off







Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.
Loading comments...