This European Standard specifies requirements for the execution i.e. the manufacture and the installation of cold-formed structural aluminium components made from profiled sheeting for roof, ceiling, floor and wall applications under predominately static loading conditions or seismic loading conditions and their documentation. It does cover products of structural class I and II according to EN 1999-1-4 used in structures.
Structural elements are understood here to mean profiled sheeting, such as trapezoidal, sinusoidal, liner trays or cassette profiles (Figure 1), that are produced by cold forming. Perforated and micro profiled sheeting are also covered by this part.
Welded sections are excluded from this part and are covered by EN 1090-3 except seal welding in low-stress areas.
This standard also covers spacer constructions between the outer and inner or upper and lower skins as well as supporting members for roofs, walls and ceilings made from cold-formed profiled sheeting and the connections and attachments of the afore mentioned elements as long as they are involved in load transfer, it also covers connections and attachments of these elements.
A combination of steel and aluminium structural elements are permitted, e.g. liner trays made of steel, stiffened by profiles made of aluminium. In this case, EN 1090-4 and this document apply.
Composite structural elements where the interaction between dissimilar materials are an integral part of the structural behaviour such as sandwich panels and composite floors are not covered by this standard.
NOTE   The structures covered in this standard can be for example
-   single- or multi-skin roofs, whereby the load-bearing structure (lower skin) as well as the actual roof covering (upper skin) or both consist of structural elements;
-   single- or multi-skin walls whereby the load-bearing structure (inner skin) as well as the actual cladding (outer skin) or both consist of structural elements; or
-   suspended ceilings for interior fitting.

Status
Published
Publication Date
21-Mar-2017
Withdrawal Date
29-Sep-2017
Current Stage
9092 - Decision on results of review/2YR ENQ - revise - Review Enquiry
Start Date
23-Nov-2022
Completion Date
23-Sep-2026

Buy Documents

Standard

EN 1090-5:2017 - BARVE

English language (61 pages)
Preview
Preview
e-Library read for
1 day

Overview

EN 1090-5:2017 sets the European requirements for the execution (manufacture and installation) of cold-formed structural aluminium elements used in roofs, ceilings, floors and walls. It covers profiled sheeting produced by cold forming - for example trapezoidal, sinusoidal, liner trays and cassette profiles, including perforated and micro‑profiled sheeting - for structures subjected to predominantly static or seismic loading. The standard applies to products of structural class I and II (EN 1999-1-4) and addresses documentation, traceability and on‑site execution. Welded sections are excluded (see EN 1090-3), though seal welding in low‑stress areas and mixed steel/aluminium assemblies are referenced where applicable.

Key topics and technical requirements

  • Scope of components: profiled cold‑formed aluminium sheeting, spacer constructions, supporting members and load‑bearing connections and attachments when involved in load transfer. Composite sandwich panels and floors (dissimilar material interaction) are excluded.
  • Specifications & documentation: execution specification, layout drawings, installer’s documentation, quality and traceability records, and execution documentation requirements.
  • Constituent products: material identification, thickness tolerances, minimum nominal thicknesses and surface protection.
  • Manufacturing controls: cold‑forming, cutting, punching, marking and identification of components.
  • Mechanical fastening & connections: use of self‑drilling/self‑tapping screws, blind rivets, edge/field spacing, and attachment rules for different supporting members (metal, timber, concrete).
  • Erection & site works: site conditions, storage, lifting, laying, direction of lay, inspection after installation, training/instruction for installation personnel and safety on site.
  • Tolerances & performance: geometrical, manufacturing and erection tolerances; functional tolerances; inspection, testing and correction.
  • Durability & safety: surface protection, corrosion protection, cleaning/maintenance, lightning protection, reaction and external fire performance provisions.

Practical applications

  • Specification and QA for manufacturers of cold‑formed aluminium roofing and cladding profiles.
  • Design and installation guidance for structural engineers, fabricators and installers specifying profiled sheeting for roofs, façades, ceilings and floors.
  • Compliance and project documentation for contractors, certifiers and building authorities when using cold‑formed aluminium structural elements under static or seismic conditions.
  • Reference for procurement and contract clauses covering traceability, tolerances, fastening details and on‑site inspection procedures.

Who should use this standard

  • Aluminium profile manufacturers and fabricators
  • Structural engineers and detailers working with EN 1999 (Eurocode 9)
  • Roofing/cladding installers and contractors
  • Quality managers, compliance officers and building inspectors

Related standards

  • EN 1090-3 - Execution requirements for welded aluminium structures
  • EN 1090-4 - Mixed steel and aluminium assemblies
  • EN 1999-1-4 - Structural classes and design rules for aluminium (Eurocode 9)

Keywords: EN 1090-5:2017, cold-formed structural aluminium, profiled sheeting, execution of aluminium structures, roofing cladding, mechanical fastening, traceability documentation.

Relations

Effective Date
10-Feb-2026
Effective Date
28-Jan-2026
Effective Date
28-Jan-2026
Effective Date
28-Jan-2026
Effective Date
28-Jan-2026
Effective Date
28-Jan-2026
Effective Date
28-Jan-2026
Effective Date
28-Jan-2026
Effective Date
28-Jan-2026
Effective Date
28-Jan-2026
Effective Date
28-Jan-2026
Effective Date
28-Jan-2026
Effective Date
28-Jan-2026
Effective Date
28-Jan-2026
Effective Date
28-Jan-2026

Buy Documents

Standard

EN 1090-5:2017 - BARVE

English language (61 pages)
Preview
Preview
e-Library read for
1 day

Get Certified

Connect with accredited certification bodies for this standard

DIBt (Deutsches Institut für Bautechnik)

German Institute for Building Technology.

DAKKS Germany Verified

DIN CERTCO

DIN Group product certification.

DAKKS Germany Verified

Aboma Certification B.V.

Specialized in construction, metal, and transport sectors.

RVA Netherlands Verified

Sponsored listings

Frequently Asked Questions

EN 1090-5:2017 is a standard published by the European Committee for Standardization (CEN). Its full title is "Execution of steel structures and aluminium structures - Part 5: Technical requirements for cold-formed structural aluminium elements and cold-formed structures for roof, ceiling, floor and wall applications". This standard covers: This European Standard specifies requirements for the execution i.e. the manufacture and the installation of cold-formed structural aluminium components made from profiled sheeting for roof, ceiling, floor and wall applications under predominately static loading conditions or seismic loading conditions and their documentation. It does cover products of structural class I and II according to EN 1999-1-4 used in structures. Structural elements are understood here to mean profiled sheeting, such as trapezoidal, sinusoidal, liner trays or cassette profiles (Figure 1), that are produced by cold forming. Perforated and micro profiled sheeting are also covered by this part. Welded sections are excluded from this part and are covered by EN 1090-3 except seal welding in low-stress areas. This standard also covers spacer constructions between the outer and inner or upper and lower skins as well as supporting members for roofs, walls and ceilings made from cold-formed profiled sheeting and the connections and attachments of the afore mentioned elements as long as they are involved in load transfer, it also covers connections and attachments of these elements. A combination of steel and aluminium structural elements are permitted, e.g. liner trays made of steel, stiffened by profiles made of aluminium. In this case, EN 1090-4 and this document apply. Composite structural elements where the interaction between dissimilar materials are an integral part of the structural behaviour such as sandwich panels and composite floors are not covered by this standard. NOTE The structures covered in this standard can be for example - single- or multi-skin roofs, whereby the load-bearing structure (lower skin) as well as the actual roof covering (upper skin) or both consist of structural elements; - single- or multi-skin walls whereby the load-bearing structure (inner skin) as well as the actual cladding (outer skin) or both consist of structural elements; or - suspended ceilings for interior fitting.

This European Standard specifies requirements for the execution i.e. the manufacture and the installation of cold-formed structural aluminium components made from profiled sheeting for roof, ceiling, floor and wall applications under predominately static loading conditions or seismic loading conditions and their documentation. It does cover products of structural class I and II according to EN 1999-1-4 used in structures. Structural elements are understood here to mean profiled sheeting, such as trapezoidal, sinusoidal, liner trays or cassette profiles (Figure 1), that are produced by cold forming. Perforated and micro profiled sheeting are also covered by this part. Welded sections are excluded from this part and are covered by EN 1090-3 except seal welding in low-stress areas. This standard also covers spacer constructions between the outer and inner or upper and lower skins as well as supporting members for roofs, walls and ceilings made from cold-formed profiled sheeting and the connections and attachments of the afore mentioned elements as long as they are involved in load transfer, it also covers connections and attachments of these elements. A combination of steel and aluminium structural elements are permitted, e.g. liner trays made of steel, stiffened by profiles made of aluminium. In this case, EN 1090-4 and this document apply. Composite structural elements where the interaction between dissimilar materials are an integral part of the structural behaviour such as sandwich panels and composite floors are not covered by this standard. NOTE The structures covered in this standard can be for example - single- or multi-skin roofs, whereby the load-bearing structure (lower skin) as well as the actual roof covering (upper skin) or both consist of structural elements; - single- or multi-skin walls whereby the load-bearing structure (inner skin) as well as the actual cladding (outer skin) or both consist of structural elements; or - suspended ceilings for interior fitting.

EN 1090-5:2017 is classified under the following ICS (International Classification for Standards) categories: 91.080.10 - Metal structures; 91.080.13 - Steel structures; 91.080.17 - Aluminium structures. The ICS classification helps identify the subject area and facilitates finding related standards.

EN 1090-5:2017 has the following relationships with other standards: It is inter standard links to EN 62305-3:2011, EN 1999-1-1:2023, EN 1090-1:2009+A1:2011, EN 1090-3:2019, CEN/TS 1187:2012, EN ISO 376:2011, EN ISO 11654:1997, EN 10204:2004, EN 1995-1-1:2025, EN ISO 717-1:2020, EN 508-2:2019, EN 1995-1-2:2025, EN 1999-1-4:2023, EN 13501-5:2016, EN 17293:2020. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

EN 1090-5:2017 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)


2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Ausführung von Stahltragwerken und Aluminiumtragwerken - Teil 5: Technische Anforderungen an tragende, kaltgeformte Bauelemente aus Aluminium und tragende, kaltgeformte Bauteile für Dach-, Decken-, Boden- und WandanwendungenExécution des structures en acier et des structures en aluminium - Partie 5 : Exigences techniques pour éléments en aluminium formés à froid et structures formées à froid pour applications en toiture, plafond, paroi verticale et plancherExecution of steel structures and aluminium structures - Part 5: Technical requirements for cold-formed structural aluminium elements and cold-formed structures for roof, ceiling, floor and wall applications91.080.17Aluminijaste konstrukcijeAluminium structures91.080.13Jeklene konstrukcijeSteel structuresICS:Ta slovenski standard je istoveten z:EN 1090-5:2017SIST EN 1090-5:2017en,fr,de01-september-2017SIST EN 1090-5:2017SLOVENSKI
STANDARD
EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM
EN 1090-5
March
t r s y ICS
{ sä r z rä s uâ
{ sä r z rä s y English Version
Execution of steel structures and aluminium structures æ Part
wã Technical requirements for coldæformed structural aluminium elements and coldæformed structures for roofá ceilingá floor and wall applications Exécution des structures en acier et des structures en aluminium æ Partie
w ã Exigences techniques pour éléments en aluminium formés à froid et structures formées à froid pour applications en toitureá plafondá paroi verticale et plancher
Ausführung von Stahltragwerken und Aluminiumtragwerken æ Teil
wã Technische Anforderungen an tragendeá kaltgeformte Bauelemente aus Aluminium und tragendeá kaltgeformte Bauteile für Dachæá Deckenæá Bodenæ und Wandanwendungen This European Standard was approved by CEN on
x February
t r s yä
egulations which stipulate the conditions for giving this European Standard the status of a national standard without any alterationä Upætoædate lists and bibliographical references concerning such national standards may be obtained on application to the CENæCENELEC Management Centre or to any CEN memberä
translation under the responsibility of a CEN member into its own language and notified to the CENæCENELEC Management Centre has the same status as the official versionsä
CEN members are the national standards bodies of Austriaá Belgiumá Bulgariaá Croatiaá Cyprusá Czech Republicá Denmarká Estoniaá Finlandá Former Yugoslav Republic of Macedoniaá Franceá Germanyá Greeceá Hungaryá Icelandá Irelandá Italyá Latviaá Lithuaniaá Luxembourgá Maltaá Netherlandsá Norwayá Polandá Portugalá Romaniaá Serbiaá Slovakiaá Sloveniaá Spainá Swedená Switzerlandá Turkey and United Kingdomä
EUROPEAN COMMITTEE FOR STANDARDIZATION COMITÉ EUROPÉEN DE NORMALISATION EUROPÄISCHES KOMITEE FÜR NORMUNG
CEN-CENELEC Management Centre:
Avenue Marnix 17,
B-1000 Brussels
t r s y CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Membersä Refä Noä EN
s r { ræ wã t r s y ESIST EN 1090-5:2017
...