EN 13241-1:2003+A1:2011
(Main + Amendment)Industrial, commercial and garage doors and gates - Product standard - Part 1: Products without fire resistance or smoke control characteristics
General Information
- Abstract
1.1 General
This European Standard specifies the safety and performance requirements for doors, gates and barriers, intended for installation in areas in the reach of persons, and for which the main intended uses are giving safe access for goods and vehicles accompanied or driven by persons in industrial, commercial or residential premises.
This European Standard also covers commercial doors such as rolling shutters and rolling grilles used in retail premises which are mainly provided for the access of persons rather than vehicles or goods.
These doors can include pass doors incorporated in the door leaf which are also covered by this European Standard.
These devices can be manually or power operated.
This European Standard does not cover operation in environments where the electromagnetic disturbances are outside the range of those specified in EN 61000-6-3.
1.2 Exclusions
This European Standard does not apply to the following which are intended for a different use:
- lock gates and dock gates;
- doors on lifts;
- doors on vehicles;
- armoured doors;
- doors mainly for the retention of animals;
- theatre textile curtains;
- horizontally moving manually operated pedestrian doors with a leaf size less than 6,25 m²;
- horizontally moving power operated doors less than 2,5 m wide and 6,25 m² area, designed principally for pedestrian use in accordance with prEN 12650-1;
- revolving doors of any size;
- railway barriers;
- barriers used solely for vehicles.
This European Standard does not cover the radio part of doors. If a radio operating device is used, the relevant ETSI standards should be applied in addition.
This European Standard does not contain any specific requirements for fire resistance or smoke control characteristics which are covered in prEN 13241-2.
!deleted text"
(....)
- Status
- Withdrawn
- Publication Date
- 05-Apr-2011
- Withdrawal Date
- 22-Sep-2026
- Technical Committee
- CEN/TC 33 - Doors, windows, shutters and building hardware
- Drafting Committee
- CEN/TC 33/WG 5 - Industrial, commercial and garage doors and gates
- Current Stage
- 9960 - Withdrawal effective - Withdrawal
- Start Date
- 21-Sep-2016
- Completion Date
- 23-Sep-2026
- Directive
- Not Harmonized2004/108/EC - Directive 2004/108/EC of the European Parliament and of the Council of 15 December 2004 on the approximation of the laws of the Member States relating to electromagnetic compatibility and repealing Directive 89/336/EECOJ Ref: C, C 288 OJ Date: 30-Sep-2011
Not Harmonized2004/108/EU - DIRECTIVE 2004/108/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 15 December 2004 on the approximation of the laws of the Member States relating to electromagnetic compatibility and repealing Directive 89/336/EECOJ Ref: C, C 288 OJ Date: 30-Sep-2011
Harmonized Standard2006/42/EC - Directive 2006/42/EC of the European Parliament and of the Council of 17 May 2006 on machinery, and amending Directive 95/16/EC (recast)OJ Ref: C, C 338 OJ Date: 18-Nov-2011
Harmonized Standard2014/30/EU - Directive 2014/30/EU of the European Parliament and of the Council of 26 February 2014 on the harmonisation of the laws of the Member States relating to electromagnetic compatibility (recast)OJ Ref: C, C 173 OJ Date: 13-May-2016
Harmonized Standard305/2011 - Regulation (eu) No 305/2011 of the European Parliament and of the Council of 9 march 2011 laying down harmonised conditions for the marketing of construction products and repealing council directive 89/106/eecOJ Ref: C, C 259 OJ Date: 08-Aug-2014
Not Harmonized89/106/EEC - Construction productsOJ Ref: C, C 246 OJ Date: 24-Aug-2011
Relations
- Effective Date
- 18-Jan-2023
- Effective Date
- 19-Jan-2023
- Effective Date
- 02-Jun-2026
- Effective Date
- 25-Mar-2026
- Effective Date
- 09-Feb-2026
- Effective Date
- 09-Feb-2026
- Effective Date
- 09-Feb-2026
- Effective Date
- 28-Jan-2026
- Effective Date
- 28-Jan-2026
- Effective Date
- 28-Jan-2026
- Effective Date
- 28-Jan-2026
- Effective Date
- 28-Jan-2026
- Effective Date
- 28-Jan-2026
- Effective Date
- 28-Jan-2026
- Effective Date
- 28-Jan-2026
Get Certified
Connect with accredited certification bodies for this standard
DIBt (Deutsches Institut für Bautechnik)
German Institute for Building Technology.
DIN CERTCO
DIN Group product certification.

Aboma Certification B.V.
Specialized in construction, metal, and transport sectors.
Sponsored listings
Frequently Asked Questions
EN 13241-1:2003+A1:2011 is a standard published by the European Committee for Standardization (CEN). Its full title is "Industrial, commercial and garage doors and gates - Product standard - Part 1: Products without fire resistance or smoke control characteristics". This standard covers: 1.1 General This European Standard specifies the safety and performance requirements for doors, gates and barriers, intended for installation in areas in the reach of persons, and for which the main intended uses are giving safe access for goods and vehicles accompanied or driven by persons in industrial, commercial or residential premises. This European Standard also covers commercial doors such as rolling shutters and rolling grilles used in retail premises which are mainly provided for the access of persons rather than vehicles or goods. These doors can include pass doors incorporated in the door leaf which are also covered by this European Standard. These devices can be manually or power operated. This European Standard does not cover operation in environments where the electromagnetic disturbances are outside the range of those specified in EN 61000-6-3. 1.2 Exclusions This European Standard does not apply to the following which are intended for a different use: - lock gates and dock gates; - doors on lifts; - doors on vehicles; - armoured doors; - doors mainly for the retention of animals; - theatre textile curtains; - horizontally moving manually operated pedestrian doors with a leaf size less than 6,25 m²; - horizontally moving power operated doors less than 2,5 m wide and 6,25 m² area, designed principally for pedestrian use in accordance with prEN 12650-1; - revolving doors of any size; - railway barriers; - barriers used solely for vehicles. This European Standard does not cover the radio part of doors. If a radio operating device is used, the relevant ETSI standards should be applied in addition. This European Standard does not contain any specific requirements for fire resistance or smoke control characteristics which are covered in prEN 13241-2. !deleted text" (....)
1.1 General This European Standard specifies the safety and performance requirements for doors, gates and barriers, intended for installation in areas in the reach of persons, and for which the main intended uses are giving safe access for goods and vehicles accompanied or driven by persons in industrial, commercial or residential premises. This European Standard also covers commercial doors such as rolling shutters and rolling grilles used in retail premises which are mainly provided for the access of persons rather than vehicles or goods. These doors can include pass doors incorporated in the door leaf which are also covered by this European Standard. These devices can be manually or power operated. This European Standard does not cover operation in environments where the electromagnetic disturbances are outside the range of those specified in EN 61000-6-3. 1.2 Exclusions This European Standard does not apply to the following which are intended for a different use: - lock gates and dock gates; - doors on lifts; - doors on vehicles; - armoured doors; - doors mainly for the retention of animals; - theatre textile curtains; - horizontally moving manually operated pedestrian doors with a leaf size less than 6,25 m²; - horizontally moving power operated doors less than 2,5 m wide and 6,25 m² area, designed principally for pedestrian use in accordance with prEN 12650-1; - revolving doors of any size; - railway barriers; - barriers used solely for vehicles. This European Standard does not cover the radio part of doors. If a radio operating device is used, the relevant ETSI standards should be applied in addition. This European Standard does not contain any specific requirements for fire resistance or smoke control characteristics which are covered in prEN 13241-2. !deleted text" (....)
EN 13241-1:2003+A1:2011 is classified under the following ICS (International Classification for Standards) categories: 91.090 - External structures. The ICS classification helps identify the subject area and facilitates finding related standards.
EN 13241-1:2003+A1:2011 has the following relationships with other standards: It is inter standard links to EN 13241:2003+A2:2016, EN 13241-1:2003, EN IEC 61000-6-3:2026, EN 1991-1-4:2026, EN 60204-1:1997, EN IEC 61000-6-2:2019, EN IEC 61000-6-3:2021, EN 12433-1:1999, EN 12445:2000, EN 12978:2003, EN ISO 10140-2:2021, EN 12428:2013, EN ISO 13850:2015, EN 12605:2000, EN ISO 10140-5:2021. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
EN 13241-1:2003+A1:2011 is associated with the following European legislation: EU Directives/Regulations: 2004/108/EC, 2004/108/EU, 2006/42/EC, 2014/30/EU, 305/2011, 89/106/EEC; Standardization Mandates: M/101, M/396, M/404. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.
EN 13241-1:2003+A1:2011 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.RWHVQRVWLTore - Produktnorm - Teil 1: Produkte ohne Feuer- und RauchschutzeigenschaftenPortes et portails industriels, commerciaux et de garage - Norme de produit - Partie 1: Produits sans caractéristiques coupe-feu, ni pare-fuméeIndustrial, commercial and garage doors and gates - Product standard - Part 1: Products without fire resistance or smoke control characteristics91.090Konstrukcije zunaj stavbExternal structures91.060.50Vrata in oknaDoors and windowsICS:Ta slovenski standard je istoveten z:EN 13241-1:2003+A1:2011SIST EN 13241-1:2003+A1:2011en,fr,de01-julij-2011SIST EN 13241-1:2003+A1:2011SLOVENSKI
STANDARD
EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM
EN 13241-1:2003+A1
April 2011 ICS 91.090 Supersedes EN 13241-1:2003 English Version
Industrial, commercial and garage doors and gates - Product standard - Part 1: Products without fire resistance or smoke control characteristics
Portes et portails industriels, commerciaux et de garage - Norme de produit - Partie 1: Produits sans caractéristiques coupe-feu, ni pare-fumée
Tore - Produktnorm - Teil 1: Produkte ohne Feuer- und Rauchschutzeigenschaften This European Standard was approved by CEN on 12 June 2003 and includes Amendment 1 approved by CEN on 22 February 2011.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION EUROPÄISCHES KOMITEE FÜR NORMUNG
Management Centre:
Avenue Marnix 17,
B-1000 Brussels © 2011 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 13241-1:2003+A1:2011: ESIST EN 13241-1:2003+A1:2011
Form for designation and classification of performances . 17Annex B (normative)
Procedure for the determination of values for thermal resistance . 18B.1Introduction . 18B.2Procedure . 18SIST EN 13241-1:2003+A1:2011
Safety factors to be considered in door design in respect of their resistance to wind load . 20Annex ZA (informative)
Relationship of this European Standard with the Construction Products Directive . 21ZA.1Clauses of this European Standard addressing the provisions of EU Construction Products Directive . 21ZA.2Procedures for the attestation of conformity of industrial, commercial and garage doors and gates. 22ZA.2.1General. 22ZA.2.2Procedure according to system 3 . 22ZA.3CE-marking and labelling. 23Annex ZB (informative)
!!!!Relationship between this European Standard and the Essential Requirements of EU Directive 2006/42/EC"""" . 26Annex ZC (informative)
!!!!Relationship between this European Standard and the Essential Requirements of EU Directive 2004/108/EC"""" . 27Bibliography . 28 SIST EN 13241-1:2003+A1:2011
lock gates and dock gates; doors on lifts; doors on vehicles; armoured doors; doors mainly for the retention of animals; theatre textile curtains; horizontally moving manually operated pedestrian doors with a leaf size less than 6,25 m²; horizontally moving power operated doors less than 2,5 m wide and 6,25 m² area, designed principally for pedestrian use in accordance with prEN 12650-1; revolving doors of any size; railway barriers; barriers used solely for vehicles. This European Standard does not cover the radio part of doors. If a radio operating device is used, the relevant ETSI standards should be applied in addition. This European Standard does not contain any specific requirements for fire resistance or smoke control characteristics which are covered in prEN 13241-2. !deleted text" This European Standard does not contain any specific requirement for doors which are moving because of energy stored by dedicated means from human power such as manually tensioned springs. SIST EN 13241-1:2003+A1:2011
For those tests specified in EN 61000-6-2, any degradation of performances or loss of function allowed with regard to performances criteria „A“ and „B“ shall be declared by the manufacturer. Any temporary loss of function allowed with regard to performance criteria „C“ shall be declared by the manufacturer. 4.3.5.2 Electromagnetic compatibility related to MD Directive The power operated door shall have sufficient immunity to electromagnetic disturbances to enable it to operate safely as intended and shall not fail to danger when exposed to the levels and types of disturbances as specified in EN 61000-6-2. The manufacturer of the power operated door shall design, install and wire the equipment and sub-assemblies taking into account the recommendations of the
...