EN 13077:2018
(Main)Devices to prevent pollution by backflow of potable water - Air gap with non-circular overflow (unrestricted) - Family A - Type B
General Information
- Abstract
This European Standard specifies the characteristics and the requirements of air gap with non-circular overflow (unrestricted) Family A, Type B for nominal flow velocity not exceeding 3 m/s. Air gaps are devices for protection of potable water in water installations from pollution by backflow. This European Standard applies to air gaps in factory-assembled products and to constructed air gaps in situ, and defines requirements and methods to verify and ensure compliance with this European Standard during normal working use.
- Status
- Withdrawn
- Publication Date
- 27-Mar-2018
- Withdrawal Date
- 22-Sep-2026
- Technical Committee
- CEN/TC 164 - Water supply
- Current Stage
- 9960 - Withdrawal effective - Withdrawal
- Start Date
- 01-Mar-2023
- Completion Date
- 23-Sep-2026
Relations
- Effective Date
- 04-Apr-2018
- Effective Date
- 19-Jan-2023
- Effective Date
- 28-Jan-2026
- Effective Date
- 28-Jan-2026
Get Certified
Connect with accredited certification bodies for this standard
DIBt (Deutsches Institut für Bautechnik)
German Institute for Building Technology.
DIN CERTCO
DIN Group product certification.

Kiwa BDA Testing
Building and construction product certification.
Sponsored listings
Frequently Asked Questions
EN 13077:2018 is a standard published by the European Committee for Standardization (CEN). Its full title is "Devices to prevent pollution by backflow of potable water - Air gap with non-circular overflow (unrestricted) - Family A - Type B". This standard covers: This European Standard specifies the characteristics and the requirements of air gap with non-circular overflow (unrestricted) Family A, Type B for nominal flow velocity not exceeding 3 m/s. Air gaps are devices for protection of potable water in water installations from pollution by backflow. This European Standard applies to air gaps in factory-assembled products and to constructed air gaps in situ, and defines requirements and methods to verify and ensure compliance with this European Standard during normal working use.
This European Standard specifies the characteristics and the requirements of air gap with non-circular overflow (unrestricted) Family A, Type B for nominal flow velocity not exceeding 3 m/s. Air gaps are devices for protection of potable water in water installations from pollution by backflow. This European Standard applies to air gaps in factory-assembled products and to constructed air gaps in situ, and defines requirements and methods to verify and ensure compliance with this European Standard during normal working use.
EN 13077:2018 is classified under the following ICS (International Classification for Standards) categories: 13.060.20 - Drinking water; 23.060.99 - Other valves; 91.140.60 - Water supply systems. The ICS classification helps identify the subject area and facilitates finding related standards.
EN 13077:2018 has the following relationships with other standards: It is inter standard links to EN 13077:2008, EN 13077:2023, EN 806-1:2000, EN 1717:2000. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
EN 13077:2018 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Naprave za varovanje pred onesnaženjem pitne vode zaradi povratnega toka - Prosti iztok s prelivom nekrožne oblike (neoviran) - Družina A, tip BSicherungseinrichtungen zum Schutz des Trinkwassers gegen Verschmutzung durch Rückfließen - Freier Auslauf mit nicht kreisförmigem Überlauf (uneingeschränkt) - Familie A, Typ BDispositifs de protection contre la pollution de l’eau potable par retour - Surverse avec trop-plein non circulaire (totale) - Famille A, type BDevices to prevent pollution by backflow of potable water - Air gap with non-circular overflow (unrestricted) - Family A - Type B91.140.60Sistemi za oskrbo z vodoWater supply systems23.060.99Drugi ventiliOther valves13.060.20Pitna vodaDrinking waterICS:Ta slovenski standard je istoveten z:EN 13077:2018SIST EN 13077:2018en,fr,de01-maj-2018SIST EN 13077:2018SLOVENSKI
STANDARDSIST EN 13077:20091DGRPHãþD
EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM
EN 13077
March
t r s z ICS
s uä r x rä t r Supersedes EN
s u r y yã t r r zEnglish Version
Devices to prevent pollution by backflow of potable water Family A æ Type B Dispositifs de protection contre la pollution de l 5eau potable par retour æ Surverse avec tropæplein non
Sicherungseinrichtungen zum Schutz des Trinkwassers gegen Verschmutzung durch Rückfließen æ Freier Auslauf mit nicht kreisförmigem Überlauf This European Standard was approved by CEN on
t x February
t r s zä
egulations which stipulate the conditions for giving this European Standard the status of a national standard without any alterationä Upætoædate lists and bibliographical references concerning such national standards may be obtained on application to the CENæCENELEC Management Centre or to any CEN memberä
translation under the responsibility of a CEN member into its own language and notified to the CENæCENELEC Management Centre has the same status as the official versionsä
CEN members are the national standards bodies of Austriaá Belgiumá Bulgariaá Croatiaá Cyprusá Czech Republicá Denmarká Estoniaá Finlandá Former Yugoslav Republic of Macedoniaá Franceá Germanyá Greeceá Hungaryá Icelandá Irelandá Italyá Latviaá Lithuaniaá Luxembourgá Maltaá Netherlandsá Norwayá Polandá Portugalá Romaniaá Serbiaá Slovakiaá Sloveniaá Spainá Swedená Switzerlandá Turkey and United Kingdomä
EUROPEAN COMMITTEE FOR STANDARDIZATION COMITÉ EUROPÉEN DE NORMALISATION EUROPÄISCHES KOMITEE FÜR NORMUNG
CEN-CENELEC Management Centre:
Rue de la Science 23,
B-1040 Brussels
t r s z CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Membersä Refä Noä EN
s u r y yã t r s z ESIST EN 13077:2018
Relationship between h and l for air gap Family A, Type B with rectangular overflow . 14 Annex B (normative)
Alternative overflow arrangements . 15 B.1 General . 15 B.2 Internal overflow arrangement . 15 B.3 Letterbox overflow extension arrangement . 16 Annex C (normative)
Vacuum Test . 17 C.1 Apparatus . 17 C.2 Procedure. 17 C.3 Requirement . 19
Figure 1 — Design principle 3.2 spillover level level at which water will start to overflow the receiving vessel with all outlets closed SIST EN 13077:2018
Figure 2 — Graphic symbol SIST EN 13077:2018
...