EN 1453-1:2000
(Main)Plastics piping systems with structured wall-pipes for soil and waste discharge (low and high temperature) inside buildings - Unplasticized poly(vinyl chloride) (PVC-U) - Part 1: Specifications for pipes and the system
General Information
- Abstract
This standard specifies the requirements for pipes, fittings and the system of unplasticized poly(vinyl chloride) (PVC-U) piping systems with structured-wall pipes intended to be used for soil and waste discharge (low and high temperature) inside buildings (marked with "B"). It also specifies the test parameters for the test methods referred to in this standard. It covers pipes with an external and internal smooth layer which are connected with faomed PVC-U or by radial legs in solid PVC-U. The fully foamed PVC-U pipes and spiraly wound PVC-U pipes are not covered by this standard.
- Status
- Withdrawn
- Publication Date
- 18-Jan-2000
- Withdrawal Date
- 16-Sep-2026
- Technical Committee
- CEN/TC 155 - Plastics piping systems and ducting systems
- Drafting Committee
- CEN/TC 155/WG 6 - Systems for soil and waste discharge - PVC-U
- Current Stage
- 9960 - Withdrawal effective - Withdrawal
- Start Date
- 11-Jan-2017
- Completion Date
- 17-Sep-2026
- Directive
- Harmonized Standard305/2011 - Regulation (eu) No 305/2011 of the European Parliament and of the Council of 9 march 2011 laying down harmonised conditions for the marketing of construction products and repealing council directive 89/106/eec
Not Harmonized89/106/EEC - Construction products
Relations
- Effective Date
- 18-Jan-2017
- Effective Date
- 25-Aug-2026
- Effective Date
- 25-Aug-2026
- Effective Date
- 13-May-2026
- Effective Date
- 09-Feb-2026
- Effective Date
- 09-Feb-2026
- Effective Date
- 28-Jan-2026
- Effective Date
- 28-Jan-2026
- Effective Date
- 28-Jan-2026
- Effective Date
- 28-Jan-2026
- Effective Date
- 28-Jan-2026
- Effective Date
- 28-Jan-2026
- Effective Date
- 28-Jan-2026
- Effective Date
- 28-Jan-2026
- Effective Date
- 28-Jan-2026
Get Certified
Connect with accredited certification bodies for this standard
DIBt (Deutsches Institut für Bautechnik)
German Institute for Building Technology.
DIN CERTCO
DIN Group product certification.

Aboma Certification B.V.
Specialized in construction, metal, and transport sectors.
Sponsored listings
Frequently Asked Questions
EN 1453-1:2000 is a standard published by the European Committee for Standardization (CEN). Its full title is "Plastics piping systems with structured wall-pipes for soil and waste discharge (low and high temperature) inside buildings - Unplasticized poly(vinyl chloride) (PVC-U) - Part 1: Specifications for pipes and the system". This standard covers: This standard specifies the requirements for pipes, fittings and the system of unplasticized poly(vinyl chloride) (PVC-U) piping systems with structured-wall pipes intended to be used for soil and waste discharge (low and high temperature) inside buildings (marked with "B"). It also specifies the test parameters for the test methods referred to in this standard. It covers pipes with an external and internal smooth layer which are connected with faomed PVC-U or by radial legs in solid PVC-U. The fully foamed PVC-U pipes and spiraly wound PVC-U pipes are not covered by this standard.
This standard specifies the requirements for pipes, fittings and the system of unplasticized poly(vinyl chloride) (PVC-U) piping systems with structured-wall pipes intended to be used for soil and waste discharge (low and high temperature) inside buildings (marked with "B"). It also specifies the test parameters for the test methods referred to in this standard. It covers pipes with an external and internal smooth layer which are connected with faomed PVC-U or by radial legs in solid PVC-U. The fully foamed PVC-U pipes and spiraly wound PVC-U pipes are not covered by this standard.
EN 1453-1:2000 is classified under the following ICS (International Classification for Standards) categories: 23.040.01 - Pipeline components and pipelines in general; 23.040.05 - Pipeline and its parts for external sewage systems; 91.140.80 - Drainage systems. The ICS classification helps identify the subject area and facilitates finding related standards.
EN 1453-1:2000 has the following relationships with other standards: It is inter standard links to EN 1453-1:2017, ISO 472:1988, ISO 1183:1987, EN 1329-1:2026, ISO 1043-1:1997, EN ISO 2507:2026, EN 10204:1991, EN ISO 2507-1:2017, EN ISO 13229:2011, EN ISO 13255:2017, EN ISO 2507-3:2017, EN 1905:1998, EN 744:1995, EN 1411:1996, EN 681-1:1996. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
EN 1453-1:2000 is associated with the following European legislation: EU Directives/Regulations: 305/2011, 89/106/EEC, 93/38/EEC; Standardization Mandates: M/BC/CEN/88/15. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.
EN 1453-1:2000 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Kunststoff-Rohrleitungssysteme mit Rohren mit profilierter Wandung und glatten Rohroberflächen zum Ableiten von Abwasser (niedriger und hoher Temperatur) innerhalb von Gebäuden - Weichmacherfreies Polyvinylchlorid (PVC-U) - Teil 1: Anforderungen an Rohre und das RohrleitungssystemSystemes de canalisations en plastique avec des tubes a paroi structurée pour l'évacuation des eaux-vannes et des eaux usées (a basse et a haute température) a l'intérieur des bâtiments - Poly(chlorure de vinyle) non plastifié (PVC-U) - Partie 1: Spécifications pour tubes et le systemePlastics piping systems with structured wall-pipes for soil and waste discharge (low and high temperature) inside buildings - Unplasticized poly(vinyl chloride) (PVC-U) - Part 1: Specifications for pipes and th
...