General Information

Abstract

This standard specifies the requirements for pipes, fittings and the system of unplasticized poly(vinyl chloride) (PVC-U) piping systems with structured-wall pipes intended to be used for soil and waste discharge (low and high temperature) inside buildings (marked with "B"). It also specifies the test parameters for the test methods referred to in this standard. It covers pipes with an external and internal smooth layer which are connected with faomed PVC-U or by radial legs in solid PVC-U. The fully foamed PVC-U pipes and spiraly wound PVC-U pipes are not covered by this standard.

Status
Withdrawn
Publication Date
18-Jan-2000
Withdrawal Date
16-Sep-2026
Current Stage
9960 - Withdrawal effective - Withdrawal
Start Date
11-Jan-2017
Completion Date
17-Sep-2026

Buy Documents

Relations

Effective Date
18-Jan-2017
Effective Date
25-Aug-2026
Effective Date
25-Aug-2026
Effective Date
13-May-2026
Effective Date
09-Feb-2026
Effective Date
09-Feb-2026
Effective Date
28-Jan-2026
Effective Date
28-Jan-2026
Effective Date
28-Jan-2026
Effective Date
28-Jan-2026
Effective Date
28-Jan-2026
Effective Date
28-Jan-2026
Effective Date
28-Jan-2026
Effective Date
28-Jan-2026
Effective Date
28-Jan-2026

Buy Documents

Get Certified

Connect with accredited certification bodies for this standard

DIBt (Deutsches Institut für Bautechnik)

German Institute for Building Technology.

DAKKS Germany Verified

DIN CERTCO

DIN Group product certification.

DAKKS Germany Verified

Aboma Certification B.V.

Specialized in construction, metal, and transport sectors.

RVA Netherlands Verified

Sponsored listings

Frequently Asked Questions

EN 1453-1:2000 is a standard published by the European Committee for Standardization (CEN). Its full title is "Plastics piping systems with structured wall-pipes for soil and waste discharge (low and high temperature) inside buildings - Unplasticized poly(vinyl chloride) (PVC-U) - Part 1: Specifications for pipes and the system". This standard covers: This standard specifies the requirements for pipes, fittings and the system of unplasticized poly(vinyl chloride) (PVC-U) piping systems with structured-wall pipes intended to be used for soil and waste discharge (low and high temperature) inside buildings (marked with "B"). It also specifies the test parameters for the test methods referred to in this standard. It covers pipes with an external and internal smooth layer which are connected with faomed PVC-U or by radial legs in solid PVC-U. The fully foamed PVC-U pipes and spiraly wound PVC-U pipes are not covered by this standard.

This standard specifies the requirements for pipes, fittings and the system of unplasticized poly(vinyl chloride) (PVC-U) piping systems with structured-wall pipes intended to be used for soil and waste discharge (low and high temperature) inside buildings (marked with "B"). It also specifies the test parameters for the test methods referred to in this standard. It covers pipes with an external and internal smooth layer which are connected with faomed PVC-U or by radial legs in solid PVC-U. The fully foamed PVC-U pipes and spiraly wound PVC-U pipes are not covered by this standard.

EN 1453-1:2000 is classified under the following ICS (International Classification for Standards) categories: 23.040.01 - Pipeline components and pipelines in general; 23.040.05 - Pipeline and its parts for external sewage systems; 91.140.80 - Drainage systems. The ICS classification helps identify the subject area and facilitates finding related standards.

EN 1453-1:2000 has the following relationships with other standards: It is inter standard links to EN 1453-1:2017, ISO 472:1988, ISO 1183:1987, EN 1329-1:2026, ISO 1043-1:1997, EN ISO 2507:2026, EN 10204:1991, EN ISO 2507-1:2017, EN ISO 13229:2011, EN ISO 13255:2017, EN ISO 2507-3:2017, EN 1905:1998, EN 744:1995, EN 1411:1996, EN 681-1:1996. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

EN 1453-1:2000 is associated with the following European legislation: EU Directives/Regulations: 305/2011, 89/106/EEC, 93/38/EEC; Standardization Mandates: M/BC/CEN/88/15. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.

EN 1453-1:2000 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)


2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Kunststoff-Rohrleitungssysteme mit Rohren mit profilierter Wandung und glatten Rohroberflächen zum Ableiten von Abwasser (niedriger und hoher Temperatur) innerhalb von Gebäuden - Weichmacherfreies Polyvinylchlorid (PVC-U) - Teil 1: Anforderungen an Rohre und das RohrleitungssystemSystemes de canalisations en plastique avec des tubes a paroi structurée pour l'évacuation des eaux-vannes et des eaux usées (a basse et a haute température) a l'intérieur des bâtiments - Poly(chlorure de vinyle) non plastifié (PVC-U) - Partie 1: Spécifications pour tubes et le systemePlastics piping systems with structured wall-pipes for soil and waste discharge (low and high temperature) inside buildings - Unplasticized poly(vinyl chloride) (PVC-U) - Part 1: Specifications for pipes and th
...