General Information

Abstract

This European Standard specifies requirements, test methods and performance criteria for point-type multi-sensor fire detectors for use in fire detection systems installed in buildings (see EN 54 1:2011), incorporating in one mechanical enclosure at least one optical or ionization smoke sensor and at least one heat sensor. The overall fire detection performance is determined utilizing the combination of the detected phenomena.
This European Standard provides for the assessment and verification of constancy of performance (AVCP) of point detectors using a combination of smoke and heat sensors to this EN.
Point detectors using a combination of smoke and heat sensors having special characteristics suitable for the detection of specific fire risks are not covered by this European Standard. The performance requirements for any additional functions are beyond the scope of this European Standard (e.g. additional features or enhanced functionality for which this European Standard does not define a test or assessment method).
NOTE   Certain types of detector contain radioactive materials. The national requirements for radiation protection differ from country to country and they are not specified in this European Standard.

Status
Not Published
Publication Date
20-Mar-2019
Withdrawal Date
22-Sep-2019
Current Stage
4598 - Decision to abandon - Finalization for Vote
Start Date
26-Nov-2018
Completion Date
17-Sep-2026

Buy Documents

Draft

EN 54-29:2015/oprA1:2017

English language (4 pages)
Preview
Preview
e-Library read for
1 day

Overview

EN 54-29:2015/prA1 is a CEN European standard for multi-sensor point fire detectors that combine smoke and heat sensing in a single enclosure. It defines requirements, test methods and performance criteria for point-type detectors used in building fire detection systems (referencing EN 54-1). The document also covers the assessment and verification of constancy of performance (AVCP) for these detectors. The amendment prA1 introduces clarifications and marking requirements, including formal definitions for optical and ionisation smoke sensors.

Key topics and requirements

  • Scope and exclusions
    • Applies to point multi-sensor detectors incorporating at least one smoke sensor (optical or ionisation) and at least one heat sensor.
    • Excludes detectors with special characteristics for specific fire risks and any additional functions for which tests are not defined in this standard.
  • Performance and test methods
    • Specifies performance criteria and standardized test methods to assess combined smoke-and-heat detection performance.
    • AVCP provisions for consistent manufacturing quality and conformity assessment.
  • Definitions added by amendment (prA1)
    • Type A - optical: smoke sensor sensitive to combustion products affecting absorption or scattering of radiation (IR, visible, UV).
    • Type B - ionisation: smoke sensor sensitive to combustion products affecting ionisation currents.
  • Marking and identification
    • Amendment requires marking of functional principle (Type A and/or Type B).
    • For Type B detectors containing radioactive components, prA1 mandates use of the trefoil symbol and specific head/base marking rules for detachable detectors.
  • Relationship with other standards
    • Intended for use within EN 54 fire detection family; ties to EN 54-1 for system-level requirements.

Applications and users

  • Manufacturers - design, test and certify multi-sensor point detectors to meet EN 54-29 performance and AVCP requirements.
  • Notified bodies & test laboratories - perform standardized type testing and factory production control assessments.
  • System designers and specifiers - select compliant detectors for commercial, residential and industrial building fire alarm systems.
  • Installers and maintenance teams - follow marking information (type, model, trefoil where applicable) for correct installation and regulatory compliance.
  • Authorities having jurisdiction & building owners - rely on EN 54-29 conformity for procurement and safety verification.

Related standards

  • EN 54-1 (system requirements)
  • Other EN 54 parts covering specific detector types and system components

Keywords: EN 54-29:2015/prA1, multi-sensor fire detectors, point detectors, smoke and heat sensors, Type A optical, Type B ionisation, trefoil symbol, AVCP, CEN, EN 54.

Relations

Effective Date
22-Jun-2016

Buy Documents

Draft

EN 54-29:2015/oprA1:2017

English language (4 pages)
Preview
Preview
e-Library read for
1 day

Get Certified

Connect with accredited certification bodies for this standard

CIS Institut d.o.o.

Personal Protective Equipment (PPE) certification body. Notified Body NB-2890 for EU Regulation 2016/425 PPE.

SA Slovenia Verified

Kiwa BDA Testing

Building and construction product certification.

RVA Netherlands Verified

Kmetijski inštitut Slovenije

Agricultural Institute of Slovenia. Soil testing, plant health, agricultural product analysis.

SA Slovenia Verified

Sponsored listings

Frequently Asked Questions

EN 54-29:2015/prA1 is a draft published by the European Committee for Standardization (CEN). Its full title is "Fire detection and fire alarm systems - Part 29: Multi-sensor fire detectors - Point detectors using a combination of smoke and heat sensors". This standard covers: This European Standard specifies requirements, test methods and performance criteria for point-type multi-sensor fire detectors for use in fire detection systems installed in buildings (see EN 54 1:2011), incorporating in one mechanical enclosure at least one optical or ionization smoke sensor and at least one heat sensor. The overall fire detection performance is determined utilizing the combination of the detected phenomena. This European Standard provides for the assessment and verification of constancy of performance (AVCP) of point detectors using a combination of smoke and heat sensors to this EN. Point detectors using a combination of smoke and heat sensors having special characteristics suitable for the detection of specific fire risks are not covered by this European Standard. The performance requirements for any additional functions are beyond the scope of this European Standard (e.g. additional features or enhanced functionality for which this European Standard does not define a test or assessment method). NOTE Certain types of detector contain radioactive materials. The national requirements for radiation protection differ from country to country and they are not specified in this European Standard.

This European Standard specifies requirements, test methods and performance criteria for point-type multi-sensor fire detectors for use in fire detection systems installed in buildings (see EN 54 1:2011), incorporating in one mechanical enclosure at least one optical or ionization smoke sensor and at least one heat sensor. The overall fire detection performance is determined utilizing the combination of the detected phenomena. This European Standard provides for the assessment and verification of constancy of performance (AVCP) of point detectors using a combination of smoke and heat sensors to this EN. Point detectors using a combination of smoke and heat sensors having special characteristics suitable for the detection of specific fire risks are not covered by this European Standard. The performance requirements for any additional functions are beyond the scope of this European Standard (e.g. additional features or enhanced functionality for which this European Standard does not define a test or assessment method). NOTE Certain types of detector contain radioactive materials. The national requirements for radiation protection differ from country to country and they are not specified in this European Standard.

EN 54-29:2015/prA1 is classified under the following ICS (International Classification for Standards) categories: 13.220.20 - Fire protection. The ICS classification helps identify the subject area and facilitates finding related standards.

EN 54-29:2015/prA1 has the following relationships with other standards: It is inter standard links to EN 54-29:2015. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

EN 54-29:2015/prA1 is associated with the following European legislation: EU Directives/Regulations: 305/2011; Standardization Mandates: M/109. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.

EN 54-29:2015/prA1 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)


SLOVENSKI STANDARD
01-oktober-2017
6LVWHPL]DRGNULYDQMHLQMDYOMDQMHSRåDUDWHUDODUPLUDQMHGHO9HþVHQ]RUVNL
MDYOMDOQLNLSRåDUD7RþNRYQLMDYOMDOQLNLVVHQ]RUMHPD]D]D]QDYDQMHGLPDLQWRSORWH
'RSROQLOR$
Fire detection and fire alarm systems - Part 29: Multi-sensor fire detectors - Point
detectors using a combination of smoke and heat sensors
Brandmeldeanlagen - Teil 29: Mehrfachsensor-Brandmelder - Punktförmige Melder mit
kombinierten Rauch- und Wärmesensoren
Systèmes de détection et d'alarme incendie - Partie 29 : Détecteurs d'incendie multi-
capteurs - Détecteurs ponctuels utilisant une combinaison de capteurs de fumée et de
chaleur
Ta slovenski standard je istoveten z: EN 54-29:2015/prA1
ICS:
13.220.20 3RåDUQD]DãþLWD Fire protection
13.320 Alarmni in opozorilni sistemi Alarm and warning systems
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

DRAFT
EUROPEAN STANDARD
EN 54-29:2015
NORME EUROPÉENNE
EUROPÄISCHE NORM
prA1
August 2017
ICS 13.220.20
English Version
Fire detection and fire alarm systems - Part 29: Multi-
sensor fire detectors - Point detectors using a combination
of smoke and heat sensors
Systèmes de détection et d'alarme incendie - Partie 29 : Brandmeldeanlagen - Teil 29: Mehrfachsensor-
Détecteurs d'incendie multi-capteurs - Détecteurs Brandmelder - Punktförmige Melder mit kombinierten
ponctuels utilisant une combinaison de capteurs de Rauch- und Wärmesensoren
fumée et de chaleur
This draft amendment is submitted to CEN members for enquiry. It has been drawn up by the Technical Committee CEN/TC 72.

This draft amendment A1, if approved, will modify the European Standard EN 54-29:2015. If this draft becomes an amendment,
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for inclusion of
this amendment into the relevant national standard without any alteration.

This draft amendment was established by CEN in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC
Management Centre has the same status as the official versions.

CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania,
Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Turkey and United Kingdom.
Recipients of this draft are invited to submit, with their comments, notification of any relevant patent rights of which they are
aware and to provide supporting documentation.

Warning : This document is not a European Standard. It is distributed for review and comments. It is subject to change without
notice and shall not be referred to as a European Standard.

EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION

EUROPÄISCHES KOMITEE FÜR NORMUNG
...