General Information

Abstract

This European Standard specifies requirements on durability (including mechanical strength), reliability and safety for liquid heating solar collectors. It also includes provisions for evaluation of conformity to these requirements.
It is not applicable to those collectors in which the thermal storage unit is an integral part of the collector to such an extent, that the collection process cannot be separated from the storage process for the purpose of making measurements of these two processes. It is basically applicable to concentrating collectors; thermal performance testing as given in EN 12975-2:2006, subclause 6.3. (quasi dynamic testing) is also applicable to most concentrating collector designs, from stationary non-imaging concentrators as CPCs to high concentrating tracking designs.
Collectors that are custom-built (built in, roof integrated collectors that do not comprise factory made modules and are assembled directly on the place of installation) cannot be tested in their actual form for durability, reliability and thermal performance according to this standard. Instead, a module with the same structure as the ready collector is tested. The module gross area in the case of custom built collectors should be at least 2 m2. The test is valid only for larger collectors, than the tested module.
For collectors the national and European Guidelines for Structural Planning and overhead glazing are not valid. Therefore this standard should be applied for the design of the static of the collector.

Status
Withdrawn
Publication Date
19-Oct-2010
Withdrawal Date
22-Sep-2026
Current Stage
9960 - Withdrawal effective - Withdrawal
Start Date
23-Mar-2022
Completion Date
23-Sep-2026

Buy Documents

Standard

EN 12975-1:2006+A1:2011

English language (15 pages)
Preview
Preview
e-Library read for
1 day

Relations

Effective Date
18-Jan-2023
Effective Date
18-Jan-2023
Effective Date
30-Mar-2022
Effective Date
28-Jan-2026
Effective Date
28-Jan-2026
Effective Date
28-Jan-2026
Effective Date
28-Jan-2026
Effective Date
28-Jan-2026
Effective Date
28-Jan-2026
Effective Date
28-Jan-2026
Effective Date
18-Jan-2023

Buy Documents

Standard

EN 12975-1:2006+A1:2011

English language (15 pages)
Preview
Preview
e-Library read for
1 day

Get Certified

Connect with accredited certification bodies for this standard

DNV

DNV is an independent assurance and risk management provider.

NA Norway Verified

Lloyd's Register

Lloyd's Register is a global professional services organisation specialising in engineering and technology.

UKAS United Kingdom Verified

DNV Energy Systems

Energy and renewable energy certification.

NA Norway Verified

Sponsored listings

Frequently Asked Questions

EN 12975-1:2006+A1:2010 is a standard published by the European Committee for Standardization (CEN). Its full title is "Thermal solar systems and components - Solar collectors - Part 1: General requirements". This standard covers: This European Standard specifies requirements on durability (including mechanical strength), reliability and safety for liquid heating solar collectors. It also includes provisions for evaluation of conformity to these requirements. It is not applicable to those collectors in which the thermal storage unit is an integral part of the collector to such an extent, that the collection process cannot be separated from the storage process for the purpose of making measurements of these two processes. It is basically applicable to concentrating collectors; thermal performance testing as given in EN 12975-2:2006, subclause 6.3. (quasi dynamic testing) is also applicable to most concentrating collector designs, from stationary non-imaging concentrators as CPCs to high concentrating tracking designs. Collectors that are custom-built (built in, roof integrated collectors that do not comprise factory made modules and are assembled directly on the place of installation) cannot be tested in their actual form for durability, reliability and thermal performance according to this standard. Instead, a module with the same structure as the ready collector is tested. The module gross area in the case of custom built collectors should be at least 2 m2. The test is valid only for larger collectors, than the tested module. For collectors the national and European Guidelines for Structural Planning and overhead glazing are not valid. Therefore this standard should be applied for the design of the static of the collector.

This European Standard specifies requirements on durability (including mechanical strength), reliability and safety for liquid heating solar collectors. It also includes provisions for evaluation of conformity to these requirements. It is not applicable to those collectors in which the thermal storage unit is an integral part of the collector to such an extent, that the collection process cannot be separated from the storage process for the purpose of making measurements of these two processes. It is basically applicable to concentrating collectors; thermal performance testing as given in EN 12975-2:2006, subclause 6.3. (quasi dynamic testing) is also applicable to most concentrating collector designs, from stationary non-imaging concentrators as CPCs to high concentrating tracking designs. Collectors that are custom-built (built in, roof integrated collectors that do not comprise factory made modules and are assembled directly on the place of installation) cannot be tested in their actual form for durability, reliability and thermal performance according to this standard. Instead, a module with the same structure as the ready collector is tested. The module gross area in the case of custom built collectors should be at least 2 m2. The test is valid only for larger collectors, than the tested module. For collectors the national and European Guidelines for Structural Planning and overhead glazing are not valid. Therefore this standard should be applied for the design of the static of the collector.

EN 12975-1:2006+A1:2010 is classified under the following ICS (International Classification for Standards) categories: 27.160 - Solar energy engineering. The ICS classification helps identify the subject area and facilitates finding related standards.

EN 12975-1:2006+A1:2010 has the following relationships with other standards: It is inter standard links to EN 12975-1:2006, EN 12975-1:2006/FprA1, EN 12975:2022, EN 12975-2:2006, EN ISO 9488:1999, EN 12976-1:2021, EN 12976-1:2017, EN 13203-3:2022, EN 12977-2:2018, EN 12977-1:2018, prEN 12975-1. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

EN 12975-1:2006+A1:2010 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)


2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Thermische Solaranlagen und ihre Bauteile - Kollektoren - Teil 1: Allgemeine AnforderungenInstallations solaires thermiques et leurs composants - Capteurs solaires - Partie 1 : Exigences généralesThermal solar systems and components - Solar collectors - Part 1: General requirements27.160Solar energy engineeringICS:Ta slovenski standard je istoveten z:EN 12975-1:2006+A1:2010SIST EN 12975-1:2006+A1:2011en,fr,de01-februar-2011SIST EN 12975-1:2006+A1:2011SLOVENSKI
STANDARD
EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM
EN 12975-1:2006+A1
October 2010 ICS 27.160 Supersedes EN 12975-1:2006English Version
Thermal solar systems and components - Solar collectors - Part 1: General requirements
Installations solaires thermiques et leurs composants - Capteurs solaires - Partie 1 : Exigences générales
Thermische Solaranlagen und ihre Bauteile - Kollektoren - Teil 1: Allgemeine Anforderungen This European Standard was approved by CEN on 6 February 2006 and includes Amendment 1 approved by CEN on 7 September 2010.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN Management Centre or to any CEN member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN Management Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION EUROPÄISCHES KOMITEE FÜR NORMUNG
Management Centre:
Avenue Marnix 17,
B-1000 Brussels © 2010 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 12975-1:2006+A1:2010: ESIST EN 12975-1:2006+A1:2011

b) It should be noted that, while awaiting the adoption of verifiable European criteria, existing national regulations concerning the use and/or the characteristics of this product remain in force. SIST EN 12975-1:2006+A1:2011

EN 12975-2:2006, Thermal solar systems and components – Solar collectors – Part 2: Test methods EN ISO 9488, Solar energy – Vocabulary (ISO 9488:1999) 3 Terms and definitions For the purposes of this European Standard, the terms and definitions given in EN ISO 9488 apply. 4 Symbols and units For the purposes of this European Standard, the symbols and units given in EN ISO 9488 and
EN 12975-2:2006 apply. 5
Durability and reliability 5.1
Materials and design Information about the materials and manufacture of solar collectors, including the materials they are manufactured of and their resistance to all influences which they might meet in service, retaining their operational ability are given in Annex A. SIST EN 12975-1:2006+A1:2011

f) Rain penetration, only for glazed collectors (see 5.7 of EN 12975-2:2006); g) Mechanical load (see 5.9 of EN 12975-2:2006); h) Thermal performance (see Clause 6 of EN 12975-2:2006); i) Freeze resistance, only in the cases specified in 5.8 of EN 12975-2:2006; j) Stagnation temperature (see Annex C of EN 12975-2:2006). May be combined with the high temperature resistance or exposure test. k) Final inspection (see 5.11 of EN 12975-2:2006). The optional test for impact resistance (see 5.10 of EN 12975-2:2006) shall be carried out if requested. The result shall be recorded.
NOTE Regarding the durability and reliability of elastic materials it is recommended to refer to ISO 9808 and ISO 9553. 5.3 Pass criteria 5.3.1 General The pass criteria for the reliability tests are given for each test in 5.3.2 to 5.3.10. The term "no major failure", denotes that none of the following occurs: - Absorber leakage or such deformation that permanent contact between absorber and cover is established; - Breaking or permanent deformation of cover or cover fixing; - Breaking or permanent deformation of collector fixing points or collector box; - Vacuum loss, such that vacuum or subatmospheric collectors shall be classified according to the definition in EN ISO 9488 (only applicable for vacuum and subatmospheric collectors); - Accumulation of humidity in form of condensate on the inside of the transparent cover of the collector exceeding 10 % of the aperture area.
- external Thermal Shock - Rain Penetration Test 5.3.2 Internal pressure for absorber The test pressure shall be as specified in 5.2 of EN 12975-2:2006. In the case of absorbers made of organic materials, climate conditions according to Table 2 of EN 12975-2:2006 shall be applied. After the internal pressure test, the collector shall not show any major failure as defined in 5.3.1. 5.3.3 High temperature resistance When tested in accordance with 5.3 of EN 12975-2:2006, the collector shall not show any major failure as defined in 5.3.1. 5.3.4 Exposure When tested in accordance with 5.4 of EN 12975-2:2006, the collector shall not show any major failure according to 5.3.1 and none of each potential problems of their components shall be graded 2 on the scale given in B.5.5 of EN 12975-2:2006. 5.3.5 External thermal shock When tested in accordance with 5.5 of EN 12975-2:2006, the collector shall not show any major failure as defined in 5.3.1. 5.3.6 Internal thermal shock When tested in accordance with 5.6 of EN 12975-2:2006, the collector shall not show any major failure as defined in 5.3.1. 5.3.7 Rain penetration NOTE This test is applicable only for glazed collectors. A visual check shall not show any water trace. Moreover, at least one of the following shall be fulfilled: a
...