Detail Specification: High density rectangular connectors, round removable crimp contacts

Detail specification for high-density rectangular connectors, round removable crimp contacts 15, 25, 40 to 64 contacts + protective earth contacts (PE) Termination: crimp

Bauartspezifikation: Hochpolige Rechteck-Steckverbinder mit runden auswechselbaren Crimpkontakten

Spécification particulière: Connecteurs rectangulaires haute densité à contacts circulaires démontables à sertir

Spécification particulière pour les connecteurs rectangulaires à haute densité à contacts circulaires démontables à sertir 15, 25, 40 à 64 contacts + contacts de terre de protection (PE) Sorties: serties

Podrobna specifikacija: Pravokotni vodniki visoke gostote z okroglimi snemljivimi nasadnimi kontakti

General Information

Status
Published
Publication Date
11-Sep-2007
Technical Committee
I09 - Imaginarni 09
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
23-Aug-2007
Due Date
28-Oct-2007
Completion Date
12-Sep-2007

Buy Documents

Standard

SIST EN 175301-801:2007

English language (40 pages)
Preview
Preview
e-Library read for
1 day

Relations

Effective Date
01-Feb-2010
Effective Date
09-Feb-2026
Effective Date
03-Feb-2026
Effective Date
03-Feb-2026
Effective Date
03-Feb-2026
Effective Date
03-Feb-2026
Effective Date
03-Feb-2026
Effective Date
03-Feb-2026
Effective Date
03-Feb-2026
Effective Date
03-Feb-2026

Overview

SIST EN 175301-801:2007 is the Slovenian national implementation of the European standard EN 175301-801:2006, which provides a comprehensive detail specification for high-density rectangular connectors with round, removable crimp contacts. These connectors are widely used in electronic equipment and applications requiring reliable, high-density connections. The standard defines connectors accommodating 15, 25, 40, or 64 contacts plus dedicated protective earth (PE) contacts, with crimp termination design for enhanced mechanical and electrical performance.

This standard is pertinent for manufacturers, designers, and engineers working with plug-and-socket devices, especially where high contact density and modular design are critical factors. The document sets out requirements for connector dimensions, marking, mechanical and electrical properties, and quality assessment procedures to ensure uniformity and interchangeability within the industry.

Key Topics

  • Connector Variants and Styles: The standard covers multiple fixed and free connector designs, including bulkhead and box mounting receptacles (Styles A and B), straight plugs (Style C), and connector inserts (Style E). Each style may have male (M) or female (F) contacts.
  • Contact Density and Types: Includes specifications for 15, 25, 40, and 64 signal contacts plus protective earth contacts, using removable round crimp contacts for flexibility and maintenance ease.
  • Marking and Identification: Connectors must be marked with the manufacturer’s identification, type designation, and clear marking of contact positions to ensure traceability and simplified installation.
  • Mechanical and Electrical Requirements: Defines parameters for insertion/withdrawal force, locking mechanisms, degree of protection (IP54 or higher in mated and locked state), and minimum creepage/clearance distances for safety.
  • Quality Assessment: Prescribes qualification approval processes, test schedules (visual, mechanical, electrical, climatic), and ongoing conformance testing to ensure product reliability.

Applications

High-density rectangular connectors specified in SIST EN 175301-801:2007 are essential for a wide range of practical applications:

  • Industrial Automation: Used to connect control units, sensors, and actuators in machinery, robots, and process equipment, where reliability and rapid field-servicing are necessary.
  • Electronic Equipment: Provides secure, high-density connections for devices such as data communication modules, measurement instruments, and signal processing units.
  • Power and Signal Distribution: Suitable for installations where multiple signal lines and protective earth contacts must be managed collectively in a compact form factor.
  • Transportation and Aerospace: Employed in environments requiring robust connectors that conform to stringent climatic and mechanical standards.

Ease of maintenance, thanks to removable crimp contacts, and modular system design make these connectors a preferred choice in contexts demanding both flexibility and high performance.

Related Standards

Implementing SIST EN 175301-801:2007 may also require consideration of the following related standards for compatibility, testing methods, and safety:

  • EN 61076-1 - Generic specification for connectors with assessed quality
  • EN 60512 Series - Tests and measurements for electronic connectors
  • EN 60068-1 - Environmental testing guidance
  • EN 60352-2 - Solderless crimped connections requirements and tests
  • EN 60529 - Degrees of protection by enclosures (IP Code)
  • EN 61984 - Connectors – Safety requirements and tests

These references collectively ensure connectors deliver expected performance under varied environmental, mechanical, and electrical conditions.


By adopting SIST EN 175301-801:2007, manufacturers and users benefit from harmonized guidelines for high-density rectangular connectors, facilitating quality, reliability, and interoperability across European and international markets.

Buy Documents

Standard

SIST EN 175301-801:2007

English language (40 pages)
Preview
Preview
e-Library read for
1 day

Frequently Asked Questions

SIST EN 175301-801:2007 is a standard published by the Slovenian Institute for Standardization (SIST). Its full title is "Detail Specification: High density rectangular connectors, round removable crimp contacts". This standard covers: Detail specification for high-density rectangular connectors, round removable crimp contacts 15, 25, 40 to 64 contacts + protective earth contacts (PE) Termination: crimp

Detail specification for high-density rectangular connectors, round removable crimp contacts 15, 25, 40 to 64 contacts + protective earth contacts (PE) Termination: crimp

SIST EN 175301-801:2007 is classified under the following ICS (International Classification for Standards) categories: 31.220.10 - Plug-and-socket devices. Connectors. The ICS classification helps identify the subject area and facilitates finding related standards.

SIST EN 175301-801:2007 has the following relationships with other standards: It is inter standard links to SIST EN 175301-801:2002, SIST EN ISO 14272:2002, SIST EN 60068-1:2014, SIST EN IEC 60512-1:2019, SIST EN IEC 60352-2:2025, SIST EN 60529:1997, SIST EN 61076-7-100:2007, SIST EN 61984:2009, SIST EN 60512-1-100:2012, SIST EN 60529:1997/A1:2000. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

SIST EN 175301-801:2007 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)


2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Detail Specification: High density rectangular connectors, round removable crimp contactsPodrobna specifikacija: Pravokotni vodniki visoke gostote z okroglimi snemljivimi nasadnimi kontaktiSpécification particuliere: Connecteurs rectangulaires haute densité a contacts circulaires démontables a sertirBauartspezifikation: Hochpolige Rechteck-Steckverbinder mit runden auswechselbaren CrimpkontaktenTa slovenski standard je istoveten z:EN 175301-801:2006SIST EN 175301-801:2007en31.220.10Plug-and-socket devices. ConnectorsICS:SIST EN 175301-801:20021DGRPHãþDSLOVENSKI
STANDARDSIST EN 175301-801:200701-oktober-2007

EUROPEAN STANDARD EN 175301-801 NORME EUROPÉENNE
EUROPÄISCHE NORM November 2006
CENELEC European Committee for Electrotechnical Standardization Comité Européen de Normalisation Electrotechnique Europäisches Komitee für Elektrotechnische Normung
Central Secretariat: rue de Stassart 35, B - 1050 Brussels
© 2006 CENELEC -
All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 175301-801:2006 E
ICS 31.220.10 Supersedes EN 175301-801:1999
English version
Detail Specification: High density rectangular connectors,
round removable crimp contacts
Spécification particulière: Connecteurs rectangulaires haute densité à contacts circulaires démontables à sertir
Bauartspezifikation: Hochpolige
Rechteck-Steckverbinder mit runden auswechselbaren Crimpkontakten
This European Standard was approved by CENELEC on 2006-10-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom.

Foreword This European Standard was prepared by the CENELEC BTWG 117-1 "Revision of EN 175310-801 and EN 175301-803". The text of the draft was submitted to the formal vote and was approved by CENELEC as EN 175301-801 on 2006-10-01. This European Standard supersedes EN 175301-801:1999. The following dates are proposed: – latest date by which the EN has to be implemented at national level by publication of an identical national standard or by endorsement
(dop)
2007-10-01 – latest date by which the national standards conflicting with the EN have to be withdrawn
(dow)
2009-10-01 __________
- 3 - EN 175301-801:2006 Contents Page 1 Scope.5 2 Normative references.6 3 Type designation.7 4 Common features.8 4.1 Isometric view.8 4.2 Mating information.8 4.3 Survey of styles.10 5 Dimensions.12 5.1 General.12 5.2 Connector with male contacts.12 5.3 Connector with female contacts.16 5.4 Marking.20 5.5 Contacts.21 5.6 Locking mechanism.21 5.7 Connector housing, metal version.22 5.8 Mounting dimensions.25 6 Gauges.26 6.1 Sizing gauge and retention force gauge.26 6.2 Locking (latching) mechanism gauges.27 7 Characteristics.30 7.1 Climatic category.30 7.2 Electrical characteristics.30 7.3 Mechanical characteristics.32 8 Test schedule.33 8.1 General.33 8.2 Test group P (preliminary).34 8.3 Test groups AP, BP and CP.35 9 Quality assessment procedures.38 9.1 Qualification approval testing.38 9.2 Quality Conformance Inspection.39 9.3 Delayed delivery, re-inspection.41 10 Ordering information.40 Figure 1 – Isometric view.7 Figure 2 – Plug-in direction.7 Figure 3 – Perpendicular to plug-in direction.8 Figure 4 – Inclination.8 Figure 5 – Fixed connector – Style A.9 Figure 6 – Fixed connector – Style B.9 Figure 7 – Free connector – Style C.10 Figure 8 – Free connector – Style E.10 Figure 9 – Connector with male contacts – Dimensions.11 Figure 10 – Connector insert E 015M.12 Figure 11 – Connector insert E 025M.12 Figure 12 – Connector insert E 040M.13 Figure 13 – Connector insert E 064M.14

Figure 14 – Connector with female contacts – Dimensions.15 Figure 15 – Connector insert E 015.16 Figure 16 – Connector insert E 025.16 Figure 17 – Connector insert E 040F.17 Figure 18 – Connector insert E 064F.18 Figure 19 – Locking mechanism – 15 + PE and 25 + PE.20 Figure 20 – Locking mechanism – 40 + PE and 64 + PE.20 Figure 21 – Style A – Transversal locking levers (S).21 Figure 22 – Style A – Longitudinal locking lever (L).21 Figure 23 – Style B – Transversal locking levers (S).21 Figure 24 – Style B – Longitudinal locking lever (L).22 Figure 25 – Style C – Transversal locking pins (S).22 Figure 26 – Style C – Longitudinal locking pins (L).22 Figure 27 – Mounting dimensions.24 Figure 28 – Sizing gauge and retention force gauge.25 Figure 29 – Locking (latching) mechanism gauge –
Transversal locking levers (S) (40, 64 + PE contacts).26 Figure 30 – Locking (latching) mechanism gauge –
Longitudinal locking lever (L) (15, 25 + PE contacts).27 Figure 31 – Locking (latching) mechanism gauge –
Longitudinal locking lever (L) (40, 64 + PE contacts).28 Figure 32 – Derating curves.30 Figure 33 – Arrangement for static load, transverse test.31 Table 1 – Plug-in direction – Dimensions.7 Table 2 – Connector with male contacts – Dimensions.11 Table 3 – Connector with female contacts – Dimensions.15 Table 4 – Locking mechanism – Dimensions.20 Table 5 – Connector housing, metal version – Dimensions according Figure 21 to 26.23 Table 6 – Mounting dimensions.24 Table 7 – Sizing gauge and retention force gauge.25 Table 8 – Locking (latching) mechanism gauge – Transversal locking lever (S) (40, 64 + PE contacts).26 Table 9 – Locking (latching) mechanism gauge –
Longitudinal locking lever (L) (15, 25 + PE contacts).27 Table 10 – Locking (latching) mechanism gauge – Longitudinal locking lever (L) (40, 64 + PE contacts).26 Table 11 – Climatic category.29 Table 12 – Clearance and creepage information.29 Table 13 – Test group information.32 Table 14 – Group P test sequence.33 Table 15 – Group AP test sequence.34 Table 16 – Group BP test sequence.35 Table 17 – Group CP test sequence.36 Table 18 – Group DP test sequence (crimped connections only).36 Table 19 – Qualification approval group information.37 Table 20 – Lot-by-lot tests.38 Table 21 – Periodic tests.39 Table 22 – Delayed delivery, re-inspection.40

- 5 - EN 175301-801:2006
ELECTRONIC COMPONENTS OF ASSESSED QUALITY – DETAIL SPECIFICATION IN ACCORDANCE WITH EN 61076-1:1995 EN 175301-801:2006See Clause 5 for dimensions
1 Scope Detail specification for high-density rectangular connectors, round removable crimp contacts
15, 25, 40 to 64 contacts + protective earth contacts (PE)
Termination: crimp _________________________________________Performance level: 1 Assessment levels: B and G (*)
Climatic category: see 7.1 Electrical characteristics: see 7.2 Mechanical characteristics: see 7.3 Ordering information: see Clause 10 (*) see Clauses 8 and 9
Information about manufacturers who have components qualified to this detail specification is available in the current CECC 00 200 (Register of Firms, Products and Services Approved under the CECC System).

2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 2591 1992 Aerospace series – Elements of electrical and optical connection – Test methods – General EN 60068-1 1994 Environmental testing – Part 1: General and guidance (IEC 60068-1:1988 + corrigendum October 1988 + A1:1992) EN 60352-2 A1 A2 1994 1997 2002 Solderless connections – Part 2: Solderless crimped connections – General requirements, test methods and practical guidance (IEC 60352-2:1990 + A1:1996 + A2:2002) EN 60512 Series Connectors for electronic equipment – Tests and measurements
(IEC 60512 series) EN 60529 A1 1991 2000 Degrees of protection provided by enclosures (IP Code) (IEC 60529:1989 + A1:1999) EN 60664-1 2003 Insulation co-ordination for equipment within low-voltage systems – Part 1: Principles, requirements and tests (IEC 60664-1:1992 + A1:2000 + A2:2002) EN 61076-1 A1 1995 1996 Connectors with assessed quality, for use in d.c., low-frequency analogue and in digital high-speed data applications – Part 1: Generic specification – Capacity approval (IEC 61076-1:1995 + A1:1996) EN 61076-7-100 2006 Connectors for electronic equipment - Product requirements – Part 7-100: Cable outlet accessories - Detail specification for a metric cable sealing consisting of an integrated part of heavy-duty rectangular or circular connector hoods and a sealing system (IEC 61076-7-100:2006) EN 61984 2001 Connectors – Safety requirements and tests (IEC 61984-1:2001) EN ISO 1043-1 2001 Plastics – Symbols and abbreviated terms – Part 1: Basic polymers and their special characteristics (ISO 1043-1:2001) EN ISO 1043-2 2001 Plastics – Symbols and abbreviated terms – Part 2: Fillers and reinforcing materials (ISO 1043-2:2000) EN ISO 1302 2002 Geometrical Product Specification (GPS) – Indication of surface texture in technical product documentation (ISO 1302:2002) EN ISO 6743-4 2001 Lubricants, industrial oils and related products (class L) – Classification – Part 4: Family H (Hydraulic systems) (ISO 6743-4:1999) EN ISO 11469 2000 Plastics – Generic identification and marking of plastics products (ISO 11469:2000) IEC 60410 1973 Sampling plans and procedures for inspections by attributes

- 7 - EN 175301-801:2006 3 Type designation Connectors, performance level and assessment level according to this specification shall be designated by the following system:
Note “L” stands for letter
“N” stands for number Examples: Connector style E, having 15 male contacts with silver alloy contact finish with crimp terminations. Complete connector without latching system and with assessment level G: EN 175301-801-E015MC-C2W-G. Connector style A, having 25 female contacts with silver alloy contact finish with crimp termination. Complete connector with latching system L and assessment level B: EN 175301-801-A025FC-C2L-B. EN175301-801

4 Common features 4.1 Isometric view
Figure 1 – Isometric view 4.2 Mating information 4.2.1 Plug-in direction The specified contact resistance must be maintained on a mated pair, within the limits of the dimensions specified.
Specified contact resistance must also be met, if the fixed and free connectors could be engaged below dimension M = 19,5 mm resp. 22,3 mm. Figure 2 – Plug-in direction Table 1 – Plug-in direction – Dimensions No. of contacts M
mm 15 + PE, 25 + PE 22,3 to 24 40 + PE, 64 + PE 19,5 to 21

- 9 - EN 175301-801:2006 4.2.2 Perpendicular to plug-in direction The design of the connectors is such that a displacement of at least 0,5 mm in transversal and longitudinal direction of the connectors can be accomodated, to achieve necessary alignment of both parts if one part to the connector pairs is float mounted. For fixed mounted connector pairs, the mounting must be kept accordingly in a sufficient small range.
Figure 3 – Perpendicular to plug-in direction 4.2.3 Inclination The design of the free and fixed connectors is such to allow for a misalignment of ± 5° in longitudinal axis and ± 2° in transverse axis. In the mated position the condition according to 4.2.1 must be met.
Figure 4 – Inclination
4.3 Survey of styles Number of contacts: 15 + PE; 25 + PE; 40 + PE; 64 + PE 4.3.1 Fixed connector Style A Bulkhead mounting receptacle 1)
Variant M, male contacts (AM)
Variant F, female co
...