Instruments and software used for measurement in high-voltage and high-current tests - Part 3: Requirements for hardware for tests with alternating and direct voltages and currents

IEC 61083-3:2020 is applicable to digital recording instruments used for measurements during tests with high alternating and direct voltages and currents. It specifies the measuring characteristics and calibrations required to meet the measuring uncertainties and procedures specified in the relevant IEC standards (e.g. IEC 60060-1, IEC 60060-2, IEC 60060-3, IEC 62475, IEC 61180).
This document is applicable to those digital recording instruments that will be designed and type tested according to this document.
This document
• defines performance requirements for digital recording instruments used during tests with alternating voltages and currents (AC) or direct voltages and currents (DC);
• specifies the necessary requirements for such instruments to ensure their suitability for use under the relevant standards;
• establishes the tests and procedures necessary to demonstrate their compliance;
• defines the terms related to digital recording instruments with recording function and access to raw data.
Examples of relevant alternating and direct voltages and currents to be measured are listed in Annex D.
This International Standard has the status of a horizontal standard in accordance with IEC Guide 108.

Messgeräte und Software für die Messung in Hochspannungs- und Hochstromprüfungen – Teil 3: Anforderungen an Messgeräte für Prüfungen mit Wechsel- und Gleichspannungen und Wechsel- und Gleichströmen

Appareils et logiciels utilisés pour les mesurages pendant les essais à haute tension et à courant élevé - Partie 3: Exigences relatives au matériel pendant les essais avec des tensions et des courants alternatifs et continus

IEC 61083-3:2020 est applicable aux instruments d'enregistrement numérique utilisés pour les mesurages pendant les essais avec des tensions et des courants alternatifs et continus élevés. Elle spécifie les caractéristiques de mesure et les étalonnages exigés pour satisfaire aux incertitudes de mesure et aux procédures spécifiées dans les normes IEC pertinentes (par exemple IEC 60060-1, IEC 60060-2, IEC 60060-3, IEC 62475, IEC 61180).
Le présent document s'applique aux instruments d'enregistrement numérique qui sont conçus et soumis aux essais conformément au présent document.
Le présent document
• définit les exigences de performance pour les instruments d'enregistrement numérique utilisés pendant les essais avec des tensions et des courants alternatifs ou des tensions et des courants continus;
• spécifie les exigences nécessaires pour ces instruments afin de garantir leur aptitude à être utilisés selon les normes pertinentes;
• établit les essais et les procédures nécessaires pour démontrer leur conformité;
• définit les termes relatifs aux instruments d'enregistrement numérique avec fonction d'enregistrement et accès aux données brutes.
Des exemples de tensions et de courants alternatifs et continus pertinents à mesurer sont énumérés à l’Annexe D.
La présente Norme internationale a le statut d'une norme horizontale conformément au Guide 108 de l'IEC.

Instrumenti in programska oprema za meritve visokih napetosti in velikih tokov - 3. del: Zahteve za strojno opremo za preskušanje z izmeničnimi in enosmernimi napetostmi in toki

General Information

Status
Published
Publication Date
22-Mar-2021
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
01-Feb-2021
Due Date
08-Apr-2021
Completion Date
23-Mar-2021
Standard
SIST EN IEC 61083-3:2021 - BARVE
English language
35 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


SLOVENSKI STANDARD
01-april-2021
Instrumenti in programska oprema za meritve visokih napetosti in velikih tokov - 3.
del: Zahteve za strojno opremo za preskušanje z izmeničnimi in enosmernimi
napetostmi in toki
Instruments and software used for measurement in high-voltage and high-current tests -
Part 3: Requirements for hardware for tests with alternating and direct voltages and
currents
Ta slovenski standard je istoveten z: EN IEC 61083-3:2021
ICS:
17.220.20 Merjenje električnih in Measurement of electrical
magnetnih veličin and magnetic quantities
19.080 Električno in elektronsko Electrical and electronic
preskušanje testing
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

EUROPEAN STANDARD EN IEC 61083-3

NORME EUROPÉENNE
EUROPÄISCHE NORM
January 2021
ICS 17.220.20; 19.080
English Version
Instruments and software used for measurement in high-voltage
and high-current tests - Part 3: Requirements for hardware for
tests with alternating and direct voltages and currents
(IEC 61083-3:2020)
Appareils et logiciels utilisés pour les mesurages pendant Messgeräte und Software für die Messung in
les essais à haute tension et à courant élevé - Partie 3: Hochspannungs- und Hochstromprüfungen - Teil 3:
Exigences relatives au matériel pendant les essais avec Anforderungen an Messgeräte für Prüfungen mit Wechsel-
des tensions et des courants alternatifs et continus und Gleichspannungen und Wechsel- und Gleichströmen
(IEC 61083-3:2020) (IEC 61083-3:2020)
This European Standard was approved by CENELEC on 2020-12-30. CENELEC members are bound to comply with the CEN/CENELEC
Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC
Management Centre or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the
same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic,
Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the
Netherlands, Norway, Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Turkey and the United Kingdom.

European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2021 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members.
Ref. No. EN IEC 61083-3:2021 E

European foreword
The text of document 42/380/FDIS, future edition 1 of IEC 61083-3, prepared by IEC/TC 42 "High-
voltage and high-current test techniques" was submitted to the IEC-CENELEC parallel vote and
approved by CENELEC as EN IEC 61083-3:2021.
The following dates are fixed:
• latest date by which the document has to be implemented at national (dop) 2021-09-30
level by publication of an identical national standard or by endorsement
• latest date by which the national standards conflicting with the (dow) 2023-12-30
document have to be withdrawn
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CENELEC shall not be held responsible for identifying any or all such patent rights.
Endorsement notice
The text of the International Standard IEC 61083-3:2020 was approved by CENELEC as a European
Standard without any modification.
In the official version, for Bibliography, the following notes have to be added for the standards
indicated:
IEC 60060-1 NOTE Harmonized as EN 60060-1
IEC 60060-3 NOTE Harmonized as EN 60060-3
IEC 60243-1 NOTE Harmonized as EN 60243-1
IEC 61000-4-2 NOTE Harmonized as EN 61000-4-2
IEC 61000-4-3 NOTE Harmonized as EN IEC 61000-4-3
IEC 61000-4-4 NOTE Harmonized as EN 61000-4-4
IEC 61000-4-5 NOTE Harmonized as EN 61000-4-5
IEC 61000-4-6 NOTE Harmonized as EN 61000-4-6
IEC 61000-4-8 NOTE Harmonized as EN 61000-4-8
IEC 61000-4-11 NOTE Harmonized as EN IEC 61000-4-11
IEC 61000-6-2 NOTE Harmonized as EN IEC 61000-6-2
IEC 61000-6-4 NOTE Harmonized as EN IEC 61000-6-4
IEC 61000-6-4:2006/A1:2010 NOTE Harmonized as EN 61000-6-4:2007/A1:2011 (not modified)
IEC 61083-1 NOTE Harmonized as EN 61083-1
IEC 61326-1 NOTE Harmonized as EN 61326-1
Annex ZA
(normative)
Normative references to international publications
with their corresponding European publications
The following documents are referred to in the text in such a way that some or all of their content
constitutes requirements of this document. For dated references, only the edition cited applies. For
undated references, the latest edition of the referenced document (including any amendments)
applies.
NOTE 1  Where an International Publication has been modified by common modifications, indicated by (mod),
the relevant EN/HD applies.
NOTE 2  Up-to-date information on the latest versions of the European Standards listed in this annex is available
here: www.cenelec.eu.
Publication Year Title EN/HD Year
IEC 60060-2 - High-voltage test techniques - Part 2: EN 60060-2 -
Measuring systems
IEC 61180 - High-voltage test techniques for low- EN 61180 -
voltage equipment - Definitions, test and
procedure requirements, test equipment
IEC 62475 - High-current test techniques - Definitions EN 62475 -
and requirements for test currents and
measuring systems
ISO/IEC Guide 98-3 2008 Uncertainty of measurement - Part 3: - -
Guide to the expression of uncertainty in
measurement (GUM:1995)
IEC 61083-3 ®
Edition 1.0 2020-11
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
colour
inside
Instruments and software used for measurement in high-voltage and

high‑current tests –
Part 3: Requirements for hardware for tests with alternating and direct voltages

and currents
Appareils et logiciels utilisés pour les mesurages pendant les essais à haute

tension et à courant élevé –
Partie 3: Exigences relatives au matériel pendant les essais avec des tensions

et des courants alternatifs et continus

INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
COMMISSION
ELECTROTECHNIQUE
INTERNATIONALE
ICS 17.220.20; 19.080 ISBN 978-2-8322-9037-8

– 2 – IEC 61083-3:2020 © IEC 2020
CONTENTS
FOREWORD . 4
INTRODUCTION . 6
1 Scope . 7
2 Normative references . 7
3 Terms and definitions . 8
3.1 Digital recording instruments . 8
3.2 Rated values . 9
3.3 Factors . 9
3.4 Dynamic performance . 9
3.5 Uncertainties. 11
3.6 Tests . 12
4 Operating conditions . 12
5 Calibration and test methods . 13
5.1 Applicability . 13
5.2 Qualification of digital recording instruments . 13
5.3 Requirements for reference generators . 13
5.4 Available methods for qualification of digital recording instruments . 13
5.5 Calibration . 14
5.6 Alternative test methods . 14
5.6.1 General . 14
5.6.2 Test of the rise time, step response . 14
5.6.3 Internal noise level . 14
5.6.4 Interference test . 14
5.6.5 Reading rate . 14
5.7 Uncertainty contribution . 15
5.8 Input impedance . 15
6 Requirements for AC and DC measurements . 15
6.1 Requirements for digital recording instruments used in approved measuring
systems . 15
6.2 Individual requirements . 15
6.2.1 General . 15
6.2.2 Scale factor . 15
6.2.3 Sampling rate . 15
6.2.4 Rated resolution . 16
6.2.5 Rise time (bandwidth) . 16
6.2.6 Noise level . 16
6.2.7 Interference . 16
6.2.8 Non-linearity of amplitude . 16
6.2.9 Record length of digital recording instruments . 16
6.3 Requirements for digital recording instruments used in reference measuring
systems . 16
6.4 Tests . 17
6.4.1 General . 17
6.4.2 Type tests . 17
6.4.3 Routine tests . 17
6.4.4 Performance tests . 17
6.4.5 Performance checks . 18

IEC 61083-3:2020 © IEC 2020 – 3 –
7 Uncertainty contributions for complete measuring systems . 18
8 Record of performance . 18
(normative) Electromagnetic interference in high-voltage and high-current
laboratories and test fields . 19
A.1 General . 19
A.2 Precautions . 19
A.2.1 Electromagnetic shielding . 19
A.2.2 Reduction of conducted interference from the supply line . 19
A.2.3 Reduction of interference on the signal line . 19
A.2.4 Signal transmission by optical means . 20
A.3 Tests with transient induced electromagnetic fields . 20
A.4 Tests with current injection . 20
(informative) Electromagnetic interference in high-voltage and high-current
laboratories and test fields – Recommendations for digital recording instruments . 22
(informative) Procedure to determine the non-linearity of amplitude of

sampling instruments . 24
(informative) Examples and considerations . 26
D.1 Suggested requirements for digital recording instruments for AC and DC
voltage measurements . 26
D.1.1 Test cases . 26
D.1.2 Background . 27
D.1.3 Recommendations for digital recording instruments for AC testing (up to
60 Hz without consideration of harmonics) . 27
D.1.4 Recommendations for digital recording instruments for DC testing
(without consideration of ripple) . 27
D.1.5 Recommendations for digital recording instruments for AC and DC
testing under consideration of harmonics or superimposed or combined
voltages . 27
D.2 Examples of relevant voltage and current characteristics to be measured . 27
D.3 Determination of the necessary rise time of instruments . 29
D.4 Considerations regarding the large variety of AC and DC measurements . 30
Bibliography . 31

Figure 1 – Integral non-linearity s(k) at code k . 10
Figure 2 – Non-linearity d(k) and code bin width w(k) under DC conditions . 11
Figure A.1 – Application of electric and magnetic fields. 20
Figure A.2 – Current injection into the shield of the cable . 21
Figure C.1 – Digitalization of a sinusoidal waveform with a 4 bit A/D converter . 24
Figure C.2 – Ideal code distribution of a sinusoidal waveform digitized by a 4 bit A/D
converter . 24
Figure C.3 – Example of a non-ideal measurement of ideal sinusoidal waveform . 25
Figure C.4 – Example of the determination of the differential non-linearity . 25

Table 1 – Operating conditions . 13
Table 2 – Tests required for digital recording instruments . 17
Table B.1 – Increased immunity levels suggested for digital recording instruments
used in high-voltage environments . 23
Table D.1 – Relevant voltages and currents . 28

– 4 – IEC 61083-3:2020 © IEC 2020
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
INSTRUMENTS AND SOFTWARE USED FOR MEASUREMENT
IN HIGH-VOLTAGE AND HIGH-CURRENT TESTS –

Part 3: Requirements for hardware for tests with alternating
and direct voltages and currents

FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote international
co-operation on all questions concerning standardization in the electrical and electronic fields. To this end and
in addition to other activities, IEC publishes International Standards, Technical Specifications, Technical Reports,
Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC Publication(s)”). Their
preparation is entrusted to technical committees; any IEC National Committee interested in the subject dealt with
may participate in this preparatory work. International, governmental and non-governmental organizations liaising
with the IEC also participate in this preparation. IEC collaborates closely with the International Organization for
Standardization (ISO) in accordance with conditions determined by agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence between
any IEC Publication and the corresponding national or regional publication shall be clearly indicated in the latter.
5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity
assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any
services carried out by independent certification bodies.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of patent
rights. IEC shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 61083-3 has been prepared by IEC technical committee 42: High-
voltage and high-current test techniques.
The text of this International Standard is based on the following documents:
FDIS Report on voting
42/380/FDIS 42/387/RVD
Full information on the voting for the approval of this International Standard can be found in the
report on voting indicated in the above table.
This document has been drafted in accordance with the ISO/IEC Directives, Part 2.

IEC 61083-3:2020 © IEC 2020 – 5 –
A list of all parts in the IEC 61083 series, published under the general title Instruments and
software used for measurement in high-voltage and high-current tests, can be found on the IEC
website.
Future standards in this series will carry the new general title as cited above. Titles of existing
standards in this series will be updated at the time of the next edition.
The committee has decided that the contents of this document will remain unchanged until the
stability date indicated on the IEC website under "http://webstore.iec.ch" in the data related to
the specific document. At this date, the document will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.
IMPORTANT – The 'colour inside' logo on the cover page of this publication indicates
that it contains colours which are considered to be useful for the correct understanding
of its contents. Users should therefore print this document using a colour printer.

– 6 – IEC 61083-3:2020 © IEC 2020
INTRODUCTION
The electric power industry requires standardized tools to provide confidence in testing results,
and to prove equivalence between tests performed in different laboratories and test fields.
This part of IEC 61083 specifies requirements for the performance of digital recording
instruments used for tests with alternating and direct voltages and currents.
The intention of this document is to provide recommendations on the digital recording
instruments to be used in tests with alternating and direct voltages and currents.
Digital recording instruments are considered as black boxes (including hardware, firmware, and
software). They are characterized for their intended application by physical calibration with the
waveforms needed for that application.
This document does not apply to simple analogue or digital meters that do not have recording
capability.
IEC 61083-3:2020 © IEC 2020 – 7 –
INSTRUMENTS AND SOFTWARE USED FOR MEASUREMENT
IN HIGH-VOLTAGE AND HIGH-CURRENT TESTS –

Part 3: Requirements for hardware for tests with alternating
and direct voltages and currents

1 Scope
This part of IEC 61083 is applicable to digital recording instruments used for measurements
during tests with high alternating and direct voltages and currents. It specifies the measuring
characteristics and calibrations required to meet the measuring uncertainties and procedures
specified in the relevant IEC standards (e.g. IEC 60060-1, IEC 60060-2, IEC 60060-3,
IEC 62475, IEC 61180).
This document is applicable to those digital recording instruments that will be designed and
type tested according to this document.
This document
• defines performance requirements for digital recording instruments used during tests with
alternating voltages and currents (AC) or direct voltages and currents (DC);
• specifies the necessary requirements for such instruments to ensure their suitability for use
under the relevant standards;
• establishes the tests and procedures necessary to demonstrate their compliance;
• defines the terms related to digital recording instruments with recording function and access
to raw data.
NOTE Examples of relevant alternating and direct voltages and currents to be measured are listed in Annex D.
This International Standard has the status of a horizontal standard in accordance with
IEC Guide 108.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content
constitutes requirements of this document. For dated references, only the edition cited applies.
For undated references, the latest edition of the referenced document (including any
amendments) applies.
IEC 60060-2, High-voltage test techniques – Part 2: Measuring systems
IEC 61180, High-voltage test techniques for low-voltage equipment – Definitions, test and
procedure requirements, test equipment
IEC 62475, High-current test techniques – Definitions and requirements for test currents and
measuring systems
ISO/IEC Guide 98-3:2008, Uncertainty of measurement – Part 3: Guide to the expression of
uncertainty in measurement (GUM:1995)

– 8 – IEC 61083-3:2020 © IEC 2020
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply.
ISO and IEC maintain terminological databases for use in standardization at the following
addresses:
• IEC Electropedia: available at http://www.electropedia.org/
• ISO Online browsing platform: available at http://www.iso.org/obp
3.1 Digital recording instruments
3.1.1
approved instrument
measuring device that is shown to comply with the requirements set out in IEC 61083-3
3.1.2
digital recording instrument
device with digital output capability of the recorded input
Note 1 to entry: This definition includes digital recorders, digital oscilloscopes, digital peak voltmeters and other
digital recording instruments if applicable.
Note 2 to entry: The waveform of the digital record is usually displayed on a screen, plotted or printed. This process
may change the appearance of the waveform due to the processing involved.
3.1.3
assigned measurement range
range of input voltage for which the digital recording instrument can be used within the
uncertainty limits given in IEC 61083-3
3.1.4
output
displayed (in any way) value of a digital recording instrument at a specific instant or the
numerical value of a digital recording instrument recorded at a specific instant
3.1.5
full-scale deflection
minimum input value, which produces the nominal maximum output of the digital recording
instrument in the specified range
3.1.6
offset
output of a digital recording instrument for zero input
3.1.7
raw data
original record of sampled and quantized information obtained when a digital recording
instrument converts an analogue signal into a digital form, with the correction of the output for
offset and multiplying the record by a constant factor being permitted
3.1.8
test duration
range of a time interval in which the measurement is done
3.1.9
reading rate
rate with which the instrument displays or stores the readings of the measured AC or DC voltage
or current
IEC 61083-3:2020 © IEC 2020 – 9 –
Note 1 to entry: In sampling instruments, readings are calculated e.g. by averaging (DC) or by calculating the RMS
value (AC) of several samples.
3.2 Rated values
3.2.1
rated resolution
r
reciprocal of two to the power of the rated number of bits N of the A/D converter, defined as
–N
r = 2
3.2.2
sampling rate
number of samples taken per unit of time
3.2.3
record length
duration of the record expressed either in a time unit or as the total number of samples
3.2.4
warm-up time
time interval from when an instrument is first switched on to when an instrument meets
operational requirements
3.3 Factors
3.3.1
scale factor
factor by which the output corrected for offset is multiplied in order to determine the measured
value of the input quantity
Note 1 to entry: Scale factor includes the ratio of any built-in or external attenuator and is determined by calibration.
3.3.2
static scale factor
scale factor for a direct voltage or a direct current input
3.3.3
non-linearity of amplitude
deviation of the actual output of a digital recording instrument from the nominal value, which is
determined by dividing the input voltage or input current by the scale factor
Note 1 to entry: The static non-linearity for a DC input voltage or current is different from the non-linearity under
dynamic conditions.
3.3.4
peak factor
numerical value calculated from the peak value divided by the RMS value of a measurement
3.4 Dynamic performance
3.4.1
integral non-linearity
s(k)
difference between corresponding points on the measured quantization characteristic and on
the ideal quantization characteristic that is based on the static scale factor
SEE: Figure 1.
– 10 – IEC 61083-3:2020 © IEC 2020
3.4.2
quantization characteristic
characteristic showing the relationship between the output of the digital recording instrument
and the direct voltage on the input which produces this output
SEE: Figure 1.
Note 1 to entry: The average slope of the quantization characteristic is equal to the reciprocal of the static scale
factor of the A/D converter.
Curve 1: Quantization characteristic of an ideal 5-bit digital recording instrument.
Curve 2: Quantization characteristic of a non-linear 5-bit digital recording instrument (the low resolution of 5 bits
has been chosen to clarify the illustration).
Figure 1 – Integral non-linearity s(k) at code k
3.4.3
code k
integer used to identify a digital level
3.4.4
code bin width
w(k)
range of input voltage or input current allocated to code k
SEE: Figure 2.
3.4.5
average code bin width
w
product of the full-scale deflection and the rated resolution
SEE: Figure 2.
Note 1 to entry: The average code bin width is approximately equal to the static scale factor.
3.4.6
differential non-linearity
d(k)
difference between a measured code bin width w(k) for code k and the average code bin width
w divided by the average code bin width w
0 0
w k − w
( )
d k=
( )
w
IEC 61083-3:2020 © IEC 2020 – 11 –

Curve 1: Quantization characteristic of an ideal 3-bit digital recording instrument.
Curve 2: Quantization characteristic of a 3 bit digital recording instrument showing large d(k) at codes k = 2, 3 and
4.
Line AB: A straight line joining the midpoints of the code bins of an ideal instrument (the low resolution of 3 bits has
been chosen to clarify the illustration).
Figure 2 – Non-linearity d(k) and code bin width w(k) under DC conditions
3.4.7
rise time
t
R
time interval within which the response to an applied step passes from 10 % to 90 % of its
steady-state amplitude
3.4.8
time base
unit of the digital recording instrument horizontal scale against which a time interval is measured
3.5 Uncertainties
3.5.1
uncertainty
parameter, associated with the result of a measurement, that characterizes the dispersion of
the values that could reasonably be attributed to the measurand
Note 1 to entry: Uncertainty is positive and given without sign.
Note 2 to entry: Uncertainty of measurement should not be confused with the tolerance of the test value.
3.5.2
standard uncertainty
uncertainty of the result of a measurement expressed as a standard deviation
[SOURCE: ISO/IEC Guide 98-3:2008, 2.3.1]

– 12 – IEC 61083-3:2020 © IEC 2020
3.6 Tests
3.6.1
calibration
set of operations that establishes, by reference to standards, the relationship which exists,
under specified conditions, between an indication and a result of a measurement
[SOURCE: IEC 60050-311:2001, 311-01-09, modified – The notes have been deleted.]
3.6.2
type test
conformity test made on one or more items representative of the production
Note 1 to entry: For a measuring system, this is understood as a test performed on a component or on a complete
measuring system of the same design to characterize it under operating conditions.
[Source: IEC 60050-151:2001, 151-16-16, modified – The note has been added.]
3.6.3
routine test
conformity test made on each individual item during or after manufacture
Note 1 to entry: This is understood as a test performed on each component or on each complete measuring system
to characterize it under operating conditions.
[Source: IEC 60050-151:2001, 151-16-17, modified – The note has been added.]
3.6.4
performance test
test performed on a complete measuring system to characterize it under operating conditions
3.6.5
performance check
simple procedure to ensure that the most recent performance test is still valid
3.6.6
record of performance
detailed record, established and maintained by the user, describing the measuring system and
containing evidence that the requirements given in IEC 61083-3 have been met, which includes
the results of the initial performance test and the schedule and results of each subsequent
performance test and performance check
4 Operating conditions
The limits of operating conditions given in Table 1 are those under which the digital recording
instrument shall operate and meet the uncertainty requirements specified for this instrument.

IEC 61083-3:2020 © IEC 2020 – 13 –
Table 1 – Operating conditions
Condition Range
Environment
Ambient temperature 5 °C to 40 °C
Ambient relative humidity (non-condensing) 10 % to 90 %
Mains power supply
Supply voltage Rated voltage ±10 % (RMS)
Rated voltage ±12 % (AC peak)
Supply frequency Rated frequency ±5 %

Any exceptions to the values given in Table 1 shall be explicitly and clearly stated in the record
of performance.
NOTE The general requirements for testing electromagnetic compatibility of electrical equipment for measurement,
control and laboratory use are described in IEC 61326-1.
5 Calibration and test methods
5.1 Applicability
A digital recording instrument may be qualified for all requirements in this document, or for a
suitable subset.
5.2 Qualification of digital recording instruments
Digital recording instruments for measurement of high voltage and/or high current are qualified
by comparative measurements against known reference systems traceable to national
standards, proving both requirements on accuracy and dynamic performance.
Qualifications are performed both as type tests performed once for each type of instrument and
routine tests performed once for each instrument, and calibrations are performed regularly on
each instrument.
For electromagnetic interference tests in high-voltage and high-current laboratories and test
fields, see recommendations in Annex B.
5.3 Requirements for reference generators
A reference waveform generator is only necessary for calibration when the digital recording
instrument contains a measurement device which is to be used as a reference instrument
(see 6.3). Otherwise any waveform generator can be used if it fulfils general requirements for
amplitude and frequency stability and noise.
NOTE An approved waveform generator can be considered qualified if the amplitude and the frequency are stable
within 0,1 % of output and the noise is < 1 % of output.
5.4 Available methods for qualification of digital recording instruments
Calibration (scale factor determination) (5.5),
Dynamic performance tests (5.6.2),
Internal noise (5.6.3),
Interference tests (5.6.4),
Displaying performance (5.6.5).

– 14 – IEC 61083-3:2020 © IEC 2020
5.5 Calibration
Calibration is the preferred method to establish the scale factor of approved digital recording
instruments. It is also the preferred method to check the time parameter determination from the
records of digital recording instruments. The actual values shall be entered in the record of
performance.
In the case of direct voltages and currents (DC) the polarity of the calibration signal shall be
that of the signal to be measured.
The output of a digital recording instrument corresponding to the applied calibration signal shall
be evaluated for a sufficient number of values in each measurement range. The scale factor is
the average of the values of the quotient of the input value and the output value. Different scale
factors may be determined for different voltage and current parameters or for different waveform
frequencies (e.g. peak values and derivations, RMS values).
The relevant frequency and time parameters of records shall be evaluated and compared with
traceable reference values.
The calibration shall be performed on each range of use for tests. A calibration curve or table
of scale factors may be developed to reduce the effects of non-linear converter characteristics.
5.6 Alternative test methods
5.6.1 General
Alternative test methods shall be applied if a calibration according to 5.5 is not possible. While
the calibration is the recommended method, such test methods may be used if the type of
instrument does not allow a calibration or they may be used in addition to the calibration.
5.6.2 Test of the rise time, step response
Apply a step with a rise time, which is less than 20 % of the specified rise time limit (see 6.2.5)
required for the application. Measure the rise time of the output as the time from 10 % to 90 %
of the settling level. The amplitude of the applied step shall be (95 ± 5) % of the full-scale
deflection.
This rise time shall be determined at least at 5 levels (preferably with a constant quotient
between levels, e.g. 1, 2, 5, 10 sequence), over the operating range.
NOTE A standard waveform generator up to a few kHz can be used for this task since usually the test frequencies
are below 400 Hz (see Clause D.1).
5.6.3 Internal noise level
A direct voltage within the range of the digital recording instrument shall be applied.
Enough records shall be taken at a specified sampling rate to acquire at least 10 samples. The
standard deviation of these samples is taken as the internal noise level.
5.6.4 Interference test
Annex A gives the requirements for interference tests.
5.6.5 Reading rate
The reading rate shall be sufficient to catch the voltage preceding the breakdown with required
accuracy during tests.
NOTE The reading rate is not the sampling rate.

IEC 61083-3:2020 © IEC 2020 – 15 –
5.7 Uncertainty contribution
The manufacturer shall provide uncertainty estimates for quantities relevant to the intended
application. The uncertainty contributions can then be used to evaluate the uncertainty
according to IEC 60060-2, IEC 62475, IEC 61180 and IEC 61083-4 .
5.8 Input impedance
Depending on the type of measuring system used, the input impedance of the instrument may
influence the scale factor and response of a measuring system. For this reason, the input
impedance of the digital recording instrument (resistance and capacitance) shall be stated.
6 Requirements for AC and DC measurements
6.1 Requirements for digital recording instruments used in approved measuring
systems
The expanded uncertainty contribution for a measurement by digital recording instruments
according to this document and used in an approved measuring system according to
IEC 60060-2, IEC 61180 and IEC 62475, shall not be more than (at a confidence level of not
less than 95 %)
• 1 % in the voltage (current) measurement,
• 1 % in the measurement of the time and frequency parameters.
These uncertainties shall be estimated according to ISO/IEC Guide 98-3:2008.
NOTE The estimated uncertainty of the digitizer is used as a component of uncertainty of the complete
measurement system according to IEC 60060-2, IEC 61180 or IEC 62475.
6.2 Individual requirements
6.2.1 General
In order to stay within the limits given in 6.1, the limits for individual contributions given in 6.2
should usually be met. In some cases, one or more of these limits may be exceeded provided
the permitted overall uncertainty specified in 6.1 is not exceeded.
6.2.2 Scale factor
The scale factor shall be constant within ±1 % over the time intervals or frequency range and
shall be determined with an uncertainty of not more than 1 %.
6.2.3 Sampling rate
The sampling rate after signal processing shall be high enough for capturing the peak value
with the required uncertainty (see Clause D.1).
The above requirement is met usually when the sampling rate is not less than N/T where N is
the number of samples per period of the highest harmonic and T is the cycle duration of the
highest harmonic to be measured with the specified uncertainty U . N is given by
SR
π/arcos(1-U ).
SR
NOTE For a measurement with an uncertainty U of 1 %, N will be 23 samples per period. This leads for AC
SR
(f = 50 Hz, without harmonics) to a minimal sampling rate = 1,2 kS/s and for AC (f = 60 Hz, without harmonics) to a
minimal sampling rate = 1,4 kS/s.
_____________
Under preparation. Stage at the time of publication IEC ACD 61083-4:2020.

– 16 – IEC 61083-3:2020 © IEC 2020
For a measurement of an AC signal with up to 7th harmonics and with an uncertainty U of 0,3 %, N will be 284
SR
samples per period. This leads for AC (f = 50 Hz) to a minimal sampling rate = 14,2 kS/s and for AC (f = 60 Hz) to a
minimal sampling rate = 17,0 kS/s.
6.2.4 Rated resolution
The rated resolution required depends on the parameters to be measured and the required
uncertainty (see Clause D.1).
6.2.5 Rise time (bandwidth)
The necessary rise time of a digital recording instrument depends on the uncertainty
requirements (6.1) and this relates directly to the analogue bandwidth of the digital recording
instrument. The rise time t shall not be more than 1/(18 · f ) where f is the highest
R MAX MAX
frequency contained in the signal to be measured with an uncertainty of not more than 1 %. For
more information refer to Clause D.3.
6.2.6 Noise level
The internal noise level shall be < 0,1 % of the low end of the specified measurement range for
normal use.
6.2.7 Interference
The digital recording instrument (or the digital recordi
...

Questions, Comments and Discussion