Inlet air cleaning equipment for internal combustion engines and compressors — Performance testing

This document establishes and specifies uniform test procedures, conditions, equipment and a performance report to permit the direct laboratory performance comparison of air cleaners. The basic performance characteristics of greatest interest are air flow restriction or differential pressure, dust collection efficiency, dust capacity and oil carry-over on oil bath air cleaners. This test code therefore deals with the measurement of these parameters. This document is applicable to air cleaners used on internal combustion engines and compressors generally used in automotive and industrial applications.

Séparateurs aérauliques placés à l'entrée des moteurs à combustion interne et des compresseurs — Détermination des performances

General Information

Status
Published
Publication Date
10-Sep-2020
Current Stage
9092 - International Standard to be revised
Start Date
27-Feb-2023
Completion Date
19-Apr-2025
Ref Project

Relations

Standard
ISO 5011:2020 - Inlet air cleaning equipment for internal combustion engines and compressors -- Performance testing
English language
50 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)


INTERNATIONAL ISO
STANDARD 5011
Fourth edition
2020-09
Inlet air cleaning equipment for
internal combustion engines and
compressors — Performance testing
Séparateurs aérauliques placés à l'entrée des moteurs à combustion
interne et des compresseurs — Détermination des performances
Reference number
©
ISO 2020
© ISO 2020
All rights reserved. Unless otherwise specified, or required in the context of its implementation, no part of this publication may
be reproduced or utilized otherwise in any form or by any means, electronic or mechanical, including photocopying, or posting
on the internet or an intranet, without prior written permission. Permission can be requested from either ISO at the address
below or ISO’s member body in the country of the requester.
ISO copyright office
CP 401 • Ch. de Blandonnet 8
CH-1214 Vernier, Geneva
Phone: +41 22 749 01 11
Email: copyright@iso.org
Website: www.iso.org
Published in Switzerland
ii © ISO 2020 – All rights reserved

Contents Page
Foreword .v
1 Scope . 1
2 Normative references . 1
3 Terms, definitions and symbols . 1
3.1 Terms and definitions . 1
3.2 Symbols . 3
4 Measurement accuracy and standard conditions . 4
4.1 Measurement accuracy and precision . 4
4.2 Standard conditions . 4
5 Test materials and test conditions . 4
5.1 Test dust . 4
5.1.1 Grade . 4
5.1.2 Preparation . 4
5.2 Test oil for oil bath air cleaners . 5
5.3 Absolute filter materials . 5
5.3.1 Filter media . 5
5.3.2 Validation of absolute filter media efficiency, E . 5
a
5.4 Absolute filter mass . 5
5.5 Temperature and humidity . 6
6 Test procedure for dry-type air cleaners for automotive applications .6
6.1 General . 6
6.2 Test equipment . 6
6.3 Restriction and differential pressure test . 8
6.4 Efficiency test . 8
6.4.1 Purpose . 8
6.4.2 Types . 8
6.4.3 Test procedure — Absolute filter method . 9
6.4.4 Test procedure — Direct weighing method .10
6.5 Capacity test .10
6.6 Filter element pressure collapse test.11
6.7 Variable air flow test .11
6.8 Presentation of data .12
7 Test procedure for dry-type air cleaners for industrial applications .12
7.1 General .12
7.2 Test equipment .12
7.3 Restriction and differential pressure test .13
7.4 Initial efficiency test procedure — Absolute filter method .13
7.5 Full-life efficiency and capacity test.14
7.5.1 Air cleaner dust capacity .14
7.5.2 Test procedure — Absolute filter method .14
7.5.3 Test procedure — Direct weighing method .16
7.6 Presentation of data .16
7.7 Scavenged air cleaner performance test .16
7.7.1 General.16
7.7.2 Additional equipment . .17
7.7.3 Restriction and differential pressure test .17
7.7.4 Full-life efficiency and capacity test .17
7.7.5 Presentation of data .18
7.8 Precleaner performance test .18
7.8.1 Precleaner dust removal .18
7.8.2 Precleaner efficiency .19
7.8.3 Presentation of data .19
7.9 Secondary element test procedure .19
7.9.1 General.19
7.9.2 Specific efficiency test .19
7.9.3 Expression of results .20
8 Test procedure for industrial applications of oil bath air cleaners.20
8.1 General .20
8.2 Test equipment and conditions .20
8.3 Restriction and differential pressure test .21
8.4 Oil carry-over test .21
8.5 Full life efficiency and capacity test .21
8.6 Recovery test .22
8.7 Presentation of data .22
Annex A (normative) Explanation of restriction, differential pressure and pressure loss of
an air cleaner .23
Annex B (normative) Test equipment .25
Annex C (informative) Report sheet on performance testing of air cleaner equipment
according to ISO 5011 — Automotive application .35
Annex D (informative) Report sheet on performance testing of air cleaner equipment
according to ISO 5011 — Industrial application .36
Annex E (informative) Presentation of results — Air cleaner restriction/differential
pressure versus flow.38
Annex F (informative) Presentation of results — Air cleaner capacity .39
Annex G (normative) Airflow and resistance corrections to standard conditions .40
Annex H (normative) Penetration sensitivity .42
Bibliography .50
iv © ISO 2020
...