ISO 18213-2:2007
(Main)Nuclear fuel technology — Tank calibration and volume determination for nuclear materials accountancy — Part 2: Data standardization for tank calibration
Nuclear fuel technology — Tank calibration and volume determination for nuclear materials accountancy — Part 2: Data standardization for tank calibration
ISO 18213-2:2007 presents procedures for standardizing a set of calibration data to a fixed set of reference conditions so as to minimize the effect of variations in ambient conditions that occur during the measurement process. The procedures presented herein apply generally to measurements of liquid height and volume obtained for the purpose of calibrating a tank (i.e., calibrating a tank's measurement system). When used in connection with other parts of ISO 18213, these procedures apply specifically to tanks equipped with bubbler probe systems for measuring liquid content. The standardization algorithms presented in ISO 18213-2:2007 can be profitably applied when only estimates of ambient conditions, such as temperature, are available. However, the most reliable results are obtained when relevant ambient conditions are measured for each measurement of volume and liquid height in a set of calibration data.
Technologie du combustible nucléaire — Étalonnage et détermination du volume de cuve pour la comptabilité des matières nucléaires — Partie 2: Normalisation des données pour l'étalonnage de cuve
L'ISO 18213-2:2007 décrit les modes opératoires de normalisation d'un ensemble de données d'étalonnage, en fonction d'un ensemble défini de conditions de référence, pour réduire le plus possible l'effet des variations des conditions ambiantes qui interviennent pendant le processus de mesurage. Les modes opératoires présentés s'appliquent généralement aux mesures de hauteur de liquide et de volume, obtenues en vue de l'étalonnage d'une cuve (c'est-à-dire l'étalonnage d'un système de mesure de cuve). Lorsqu'ils sont utilisés conjointement avec les autres parties de l'ISO 18213, ces modes opératoires s'appliquent spécifiquement aux cuves équipées de systèmes de cannes de bullage pour le mesurage du liquide contenu. Les algorithmes de normalisation présentés dans l'ISO 18213-2:2007 peuvent être utilisés avec profit, même si l'on ne dispose que d'estimations des conditions ambiantes, telles que la température. Cependant, les résultats les plus fiables sont obtenus quand les conditions ambiantes sont mesurées à chaque mesurage de volume et de hauteur du liquide, dans un ensemble défini de données d'étalonnage.
General Information
Standards Content (Sample)
INTERNATIONAL ISO
STANDARD 18213-2
First edition
2007-11-15
Nuclear fuel technology — Tank
calibration and volume determination for
nuclear materials accountancy —
Part 2:
Data standardization for tank calibration
Technologie du combustible nucléaire — Étalonnage et détermination
du volume de cuve pour la comptabilité des matières nucléaires —
Partie 2: Normalisation des données pour l’étalonnage de cuve
Reference number
©
ISO 2007
PDF disclaimer
This PDF file may contain embedded typefaces. In accordance with Adobe’s licensing policy, this file may be printed or viewed but
shall not be edited unless the typefaces which are embedded are licensed to and installed on the computer performing the editing. In
downloading this file, parties accept therein the responsibility of not infringing Adobe’s licensing policy. The ISO Central Secretariat
accepts no liability in this area.
Adobe is a trademark of Adobe Systems Incorporated.
Details of the software products used to create this PDF file can be found in the General Info relative to the file; the PDF-creation
parameters were optimized for printing. Every care has been taken to ensure that the file is suitable for use by ISO member bodies. In
the unlikely event that a problem relating to it is found, please inform the Central Secretariat at the address given below.
© ISO 2007
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means,
electronic or mechanical, including photocopying and microfilm, without permission in writing from either ISO at the address below or
ISO’s member body in the country of the requester.
ISO copyright office
Case postale 56 • CH-1211 Geneva 20
Tel. + 41 22 749 01 11
Fax + 41 22 749 09 47
E-mail copyright@iso.org
Web www.iso.org
Published in Switzerland
ii © ISO 2007 – All rights reserved
Contents Page
Foreword. iv
Introduction . v
1 Scope . 1
2 Physical principles . 1
3 Data required. 1
4 Calibration data. 3
4.1 General. 3
4.2 Liquid height . 5
4.3 Volume . 6
5 Dimensional changes in the tank. 7
5.1 Thermodynamic basis. 7
5.2 Volume . 8
5.3 Height. 8
6 Multiple calibration runs . 8
6.1 Notation . 8
6.2 Heel volume. 8
6.3 Run alignment . 9
7 Results — Standardized calibration data. 9
Annex A (informative) Density of water . 10
Annex B (informative) Buoyancy corrections for mass determination . 11
Annex C (informative) Determination of tank heel volume . 12
Annex D (informative) Statistical method for aligning data from several calibration runs . 14
Bibliography . 15
Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards bodies
(ISO member bodies). The work of preparing International Standards is normally carried out through ISO
technical committees. Each member body interested in a subject for which a technical committee has been
established has the right to be represented on that committee. International organizations, governmental and
non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the
International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization.
International Standards are drafted in accordance with the rules given in the ISO/IEC Directives, Part 2.
The main task of technical committees is to prepare International Standards. Draft International Standards
adopted by the technical committees are circulated to the member bodies for voting. Publication as an
International Standard requires approval by at least 75 % of the member bodies casting a vote.
Attention is drawn to the possibility that some of the elements of this document may be the subject of patent
rights. ISO shall not be held responsible for identifying any or all such patent rights.
ISO 18213-2 was prepared by Technical Committee ISO/TC 85, Nuclear energy, Subcommittee SC 5,
Nuclear fuel technology.
ISO 18213 consists of the following parts, under the general title Nuclear fuel technology — Tank calibration
and volume determination for nuclear materials accountancy:
⎯ Part 1: Procedural overview
⎯ Part 2: Data standardization for tank calibration
⎯ Part 3: Statistical methods
⎯ Part 4: Accurate determination of liquid height in accountancy tanks equipped with dip tubes, slow
bubbling rate
⎯ Part 5: Accurate determination of liquid height in accountancy tanks equipped with dip tubes, fast
bubbling rate
⎯ Part 6: Accurate in-tank determination of liquid density in accountancy tanks equipped with dip tubes
iv © ISO 2007 – All rights reserved
Introduction
ISO 18213 deals with the acquisition, standardization, analysis, and use of calibration data to determine liquid
volumes in process tanks for accountability purposes. This part of ISO 18213 complements the other parts,
which include ISO 18213-1 (procedural overview), ISO 18213-3 (statistical methods), ISO 18213-4 (slow
bubbling rate), ISO 18213-5 (fast bubbling rate) and ISO 18213-6 (in-tank determination of liquid density).
Measurements of the volume and height of liquid in a process accountancy tank are often made in order to
estimate or verify the tank’s calibration or volume measurement equation. The calibration equation relates the
response of the tank’s measurement system to some independent measure of tank volume. The ultimate
purpose of the calibration exercise is to estimate the tank’s volume measurement equation (the inverse of the
calibration equation), which relates tank volume to measurement system response. In this part of ISO 18213,
it is assumed that the primary measurement-system response variable is liquid height and that the primary
measure of liquid content is volume.
Beginning with an empty tank, calibration data are typically acquired by introducing a series of carefully
measured quantities of some calibration liquid into the tank. The quantity of liquid added, the response of the
tank’s measurement system and relevant ambient conditions, such as temperature, are measured for each
incremental addition. Typically, several calibration runs are made to obtain data for estimating or verifying a
tank’s calibration or measurement equation. A procedural overview of the tank calibration and volume
measurement process is given in ISO 18213-1.
Changes in ambient conditions, especially variations in temperature, that occur during calibration can
adversely affect the quality of the calibration data and, consequently, the reliability of the calibration or volume
measurement equation determined from them. Results are also affected by differences in ambient conditions
prevailing during calibration and at the time of subsequent measurements made to determine process liquid
volumes. The purpose of this part of ISO 18213 is to present an algorithm for standardizing tank calibration
and volume measurement data so as to minimize the effects of variability in ambient conditions prevailing at
the time of measurement. Data standardization, as the term is used in this part of ISO 18213, refers to the
steps taken to adjust raw data to compensate for departures in measurement conditions from a fixed set of
reference conditions. The goal is to obtain a set of standardized calibration data, i.e. a series of pairs of height
and volume determinations from one or more calibration runs that are standardized to a fixed set of reference
conditions. These standardized data can be used to make reliable estimates of the tank’s calibration or
measurement equation, which is used, in turn, to determine the volume (at reference conditions) of process
liquid in the tank.
This part of ISO 18213 pertains to measurements of liquid height and volume obtained during the tank
calibration process. For tanks equipped with pressure-measurement systems to determine liquid content, it is
necessary to convert pressure measurements to measures of liquid height before the steps of this part of
ISO 18213 can be applied. A procedure for determining liquid height from pressure is given in either
ISO 18213-4 (slow bubbling rate) or ISO 18213-5 (fast bubbling rate), as appropriate. Other standardization
steps presented herein are generally independent of the measurement systems employed. Therefore, with
suitable modifications, the methods of this part of ISO 18213 are applicable to a variety of measurement
systems.
INTERNATIONAL STANDARD ISO 18213-2:2007(E)
Nuclear fuel technology — Tank calibration and volume
determination for nuclear materials accountancy —
Part 2:
Data standardization for tank calibration
1 Scope
This part of ISO 18213 presents procedures for standardizing a set of calibration data to a fixed set of
reference conditions so as to minimize the effect of variations in ambient conditions that occur during the
measurement process. The procedures presented herein apply generally to measurements of liquid height
and volume obtained for the purpose of calibrating a tank (i.e. calibrating a tank’s measurement system).
When used in connection with other parts of ISO 18213, these procedures apply specifically to tanks equipped
with bubbler probe systems for measuring liquid content.
The standardization algorithms presented herein can be profitably applied when only estimates of ambient
conditions, such as temperature, are available. However, the most reliable results are obtained when relevant
ambient conditions are measured for each measurement of volume and liquid height in a set of calibration
data.
2 Physical principles
The data standardization procedures in this part of ISO 18213 are based on generally accepted
thermodynamic methods. Where appropriate, details are given either in annexes to this part of ISO 18213 or
in other parts of ISO 18213.
3 Data required
The basic input data to which the procedures of this part of ISO 18213 apply are pairs of observations that
relate the tank’s measurement system response (e.g. liquid height) to some independent measure of its liquid
capacity (e.g. volume). These data pairs are typically obtained from one or more calibration runs. A typical
1)
calibration setup is shown in Figure 1. This setup is described in greater detail in ISO 18213-1 .
The density of the calibration liquid is required at all temperatures that are observed during the calibration
exercise. Demineralized water is a preferred calibration liquid because its density has been very accurately
determined at all temperatures of interest. Moreover, equations have been developed for accurately
calculating the density of water from temperature (see Annex A). If some liquid other than water is used for
calibration, then it is necessary to determine its density with suitable accuracy to meet calibration
requirements at all measurement temperatures.
1) The calibration setup shown in Figure 1 is used for illustrative purposes. Other configurations are possible. See, for
example, Reference [1].
Key
1 liquid temperature probe(s)
2 process lines (vent, fill, empty, decontamination, sparge, sample, etc.)
3 supply-line calibration liquid
4 calibration liquid supply
5 prover vessel
6 scale
7 purge gas supply
8 differential pressure manometers
9 tank internals (coils, braces, agitator, etc.)
10 isolation barrier
P major probe
P minor probe
P reference probe
r
a
Level 2 (“density”).
b
Level 1 (“level”).
Figure 1 — Elements of
...
NORME ISO
INTERNATIONALE 18213-2
Première édition
2007-11-15
Technologie du combustible nucléaire —
Étalonnage et détermination du volume
de cuve pour la comptabilité des matières
nucléaires —
Partie 2:
Normalisation des données pour
l'étalonnage de cuve
Nuclear fuel technology — Tank calibration and volume determination
for nuclear materials accountancy —
Part 2: Data standardization for tank calibration
Numéro de référence
©
ISO 2007
PDF – Exonération de responsabilité
Le présent fichier PDF peut contenir des polices de caractères intégrées. Conformément aux conditions de licence d'Adobe, ce fichier
peut être imprimé ou visualisé, mais ne doit pas être modifié à moins que l'ordinateur employé à cet effet ne bénéficie d'une licence
autorisant l'utilisation de ces polices et que celles-ci y soient installées. Lors du téléchargement de ce fichier, les parties concernées
acceptent de fait la responsabilité de ne pas enfreindre les conditions de licence d'Adobe. Le Secrétariat central de l'ISO décline toute
responsabilité en la matière.
Adobe est une marque déposée d'Adobe Systems Incorporated.
Les détails relatifs aux produits logiciels utilisés pour la création du présent fichier PDF sont disponibles dans la rubrique General Info
du fichier; les paramètres de création PDF ont été optimisés pour l'impression. Toutes les mesures ont été prises pour garantir
l'exploitation de ce fichier par les comités membres de l'ISO. Dans le cas peu probable où surviendrait un problème d'utilisation,
veuillez en informer le Secrétariat central à l'adresse donnée ci-dessous.
DOCUMENT PROTÉGÉ PAR COPYRIGHT
© ISO 2007
Droits de reproduction réservés. Sauf prescription différente, aucune partie de cette publication ne peut être reproduite ni utilisée sous
quelque forme que ce soit et par aucun procédé, électronique ou mécanique, y compris la photocopie et les microfilms, sans l'accord écrit
de l'ISO à l'adresse ci-après ou du comité membre de l'ISO dans le pays du demandeur.
ISO copyright office
Case postale 56 • CH-1211 Geneva 20
Tel. + 41 22 749 01 11
Fax. + 41 22 749 09 47
E-mail copyright@iso.org
Web www.iso.org
Publié en Suisse
ii © ISO 2007 – Tous droits réservés
Sommaire Page
Avant-propos. iv
Introduction . v
1 Domaine d'application. 1
2 Principes physiques. 1
3 Données nécessaires . 1
4 Données d'étalonnage. 3
4.1 Généralités . 3
4.2 Hauteur de liquide. 5
4.3 Volume . 6
5 Variations dimensionnelles de la cuve. 7
5.1 Base thermodynamique . 7
5.2 Volume . 8
5.3 Hauteur . 8
6 Séquences d'étalonnage multiples. 9
6.1 Notation . 9
6.2 Volume du pied de cuve. 9
6.3 Ajustement des séquences . 9
7 Résultats — Données d'étalonnage normalisées. 9
Annexe A (informative) Masse volumique de l'eau. 11
Annexe B (informative) Corrections de la poussée de l'air pour la détermination de la masse. 12
Annexe C (informative) Détermination du volume du pied de cuve . 13
Annexe D (informative) Méthode statistique d'ajustement des données issues de plusieurs
séquences d'étalonnage . 15
Bibliographie . 16
Avant-propos
L'ISO (Organisation internationale de normalisation) est une fédération mondiale d'organismes nationaux de
normalisation (comités membres de l'ISO). L'élaboration des Normes internationales est en général confiée
aux comités techniques de l'ISO. Chaque comité membre intéressé par une étude a le droit de faire partie du
comité technique créé à cet effet. Les organisations internationales, gouvernementales et non
gouvernementales, en liaison avec l'ISO participent également aux travaux. L'ISO collabore étroitement avec
la Commission électrotechnique internationale (CEI) en ce qui concerne la normalisation électrotechnique.
Les Normes internationales sont rédigées conformément aux règles données dans les Directives ISO/CEI,
Partie 2.
La tâche principale des comités techniques est d'élaborer les Normes internationales. Les projets de Normes
internationales adoptés par les comités techniques sont soumis aux comités membres pour vote. Leur
publication comme Normes internationales requiert l'approbation de 75 % au moins des comités membres
votants.
L'attention est appelée sur le fait que certains des éléments du présent document peuvent faire l'objet de
droits de propriété intellectuelle ou de droits analogues. L'ISO ne saurait être tenue pour responsable de ne
pas avoir identifié de tels droits de propriété et averti de leur existence.
L'ISO 18213-2 a été élaborée par le comité technique ISO/TC 85, Énergie nucléaire, sous-comité SC 5,
Technologie du combustible nucléaire.
L'ISO 18213 comprend les parties suivantes, présentées sous le titre général Technologie du combustible
nucléaire — Étalonnage et détermination du volume de cuve pour la comptabilité des matières nucléaires:
⎯ Partie 1: Aperçu général de la procédure
⎯ Partie 2: Normalisation des données pour l'étalonnage de cuve
⎯ Partie 3: Méthodes statistiques
⎯ Partie 4: Détermination précise de la hauteur de liquide dans une cuve bilan équipée de cannes de
bullage, bullage lent
⎯ Partie 5: Détermination précise de la hauteur de liquide dans une cuve bilan équipée de cannes de
bullage, bullage rapide
⎯ Partie 6: Détermination précise de la masse volumique d'un liquide dans une cuve bilan équipée de
cannes de bullage
iv © ISO 2007 – Tous droits réservés
Introduction
L'ISO 18213 porte sur l'acquisition, la normalisation, l'analyse et l'exploitation des données d'étalonnage
permettant de déterminer les volumes de liquides dans les cuves de procédé, pour des besoins de
comptabilité des matières nucléaires. La présente partie de l'ISO 18213 est complémentaire des autres
parties, qui sont l'ISO 18213-2 (normalisation des données), l'ISO 18213-3 (méthodes statistiques),
l'ISO 13213-4 (bullage lent), l'ISO 18213-5 (bullage rapide) et l'ISO 18213-6 (détermination de la masse
volumique en cuve).
Les mesurages de volume et de hauteur de liquide dans une cuve de procédé de comptabilité des matières
nucléaires sont souvent réalisés afin d'estimer ou de vérifier l'équation d'étalonnage ou de mesurage du
volume de la cuve. L'équation d'étalonnage fait le lien entre la réponse du système de mesure de la cuve et
une mesure indépendante du volume de celle-ci. Le but de la séquence d'étalonnage est d'estimer l'équation
de mesure du volume (l'inverse de l'équation d'étalonnage) qui fait le lien entre le volume de la cuve et la
réponse du système de mesure. Dans la présente partie de l'ISO 18213, on suppose que la variable de
réponse du système de mesure primaire est la hauteur de liquide et que la mesure primaire du liquide
contenu est le volume.
On part d'une cuve vide, puis, en général, les données sont acquises par l'introduction dans la cuve d'une
série de quantités de liquide d'étalonnage soigneusement mesurées. La quantité de liquide ajoutée dans la
cuve, la réponse du système de mesure de la cuve et les conditions ambiantes du moment, telles que la
température, sont mesurées pour chaque addition d'incrément. En règle générale, on réalise plusieurs
séquences d'étalonnage en vue d'obtenir des données pour estimer ou vérifier une équation d'étalonnage ou
de mesure du volume de la cuve. L'ISO 18213-1 donne un aperçu des processus d'étalonnage et de
mesurage du volume de la cuve.
Les changements de conditions d'ambiance, en particulier les variations de température, qui interviennent
pendant l'étalonnage peuvent avoir une incidence défavorable sur la qualité des données d'étalonnage et, par
la suite, sur la fiabilité de l'équation d'étalonnage ou de mesure qui en découle. Les résultats peuvent aussi
être soumis à l'influence des différences de conditions ambiantes rencontrées pendant l'étalonnage et au
moment où sont effectués les mesurages visant à déterminer les volumes de liquide de procédé. L'objet de la
présente partie de l'ISO 18213 est de présenter un algorithme de normalisation des données d'étalonnage et
de mesure du volume pour réduire le plus possible les effets de la variabilité des conditions ambiantes
rencontrées au moment du mesurage. La normalisation des données, au sens de ce terme dans la présente
partie de l'ISO 18213, traite des étapes permettant d'ajuster les données brutes pour compenser les écarts
entre les conditions de mesurage et un ensemble défini de conditions de référence. Le but est d'obtenir un
ensemble de données d'étalonnage normalisées, c'est-à-dire une série de couples de mesures de hauteur et
de volume issues d'une ou de plusieurs séquences d'étalonnage qui soient normalisées par rapport à un
ensemble défini de conditions de référence. Ces données normalisées peuvent être utilisées pour obtenir des
estimations fiables de l'équation d'étalonnage ou de mesure, laquelle est, à son tour, utilisée pour déterminer
le volume (dans les conditions de référence) du liquide de procédé dans la cuve.
La présente partie de l'ISO 18213 se rapporte aux mesurages de hauteur de liquide et de volume obtenus
pendant le processus d'étalonnage de la cuve. Pour les cuves équipées de systèmes de mesurage de la
pression pour déterminer le volume de liquide contenu, il est nécessaire de convertir les mesures de pression
en mesures de hauteur de liquide avant d'appliquer les étapes décrites dans la présente partie de l'ISO 18213.
Un mode opératoire de détermination de la hauteur de liquide, à partir de la pression, est indiqué soit dans
l'ISO 18213-4 (bullage lent), soit dans l'ISO 18213-5 (bullage rapide), selon le cas. Les autres étapes de
normalisation, présentées ici, sont généralement indépendantes des systèmes de mesure mis en œuvre.
Ainsi, sous réserve des modifications adaptées, les méthodes exposées dans la présente partie de
l'ISO 18213 sont applicables à tout un éventail de systèmes de mesure.
NORME INTERNATIONALE ISO 18213-2:2007(F)
Technologie du combustible nucléaire — Étalonnage et
détermination du volume de cuve pour la comptabilité des
matières nucléaires —
Partie 2:
Normalisation des données pour l'étalonnage de cuve
1 Domaine d'application
La présente partie de l'ISO 18213 décrit les modes opératoires de normalisation d'un ensemble de données
d'étalonnage, en fonction d'un ensemble défini de conditions de référence, pour réduire le plus possible l'effet
des variations des conditions ambiantes qui interviennent pendant le processus de mesurage. Les modes
opératoires présentés s'appliquent généralement aux mesures de hauteur de liquide et de volume, obtenues
en vue de l'étalonnage d'une cuve (c'est-à-dire l'étalonnage d'un système de mesure de cuve). Lorsqu'ils sont
utilisés conjointement avec les autres parties de l'ISO 18213, ces modes opératoires s'appliquent
spécifiquement aux cuves équipées de systèmes de cannes de bullage pour le mesurage du liquide contenu.
Les algorithmes de normalisation présentés peuvent être utilisés avec profit, même si l'on ne dispose que
d'estimations des conditions ambiantes, telles que la température. Cependant, les résultats les plus fiables
sont obtenus quand les conditions ambiantes sont mesurées à chaque mesurage de volume et de hauteur du
liquide, dans un ensemble défini de données d'étalonnage.
2 Principes physiques
Les modes opératoires de normalisation des données, décrits dans la présente partie de l'ISO 18213,
reposent sur des méthodes thermodynamiques largement admises. Des précisions sont fournies, le cas
échéant, dans les annexes de la présente partie de l'ISO 18213 ou dans les autres parties de l'ISO 18213.
3 Données nécessaires
Les données d'entrée fondamentales auxquelles s'appliquent les modes opératoires de la présente partie de
l'ISO 18213 sont des couples d'observations qui associent la réponse du système de mesurage de la cuve
(par exemple la hauteur
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.