ISO 23655-1:2022
(Main)Water quality — Nickel-59 and nickel-63 — Part 1: Test method using liquid scintillation counting
Water quality — Nickel-59 and nickel-63 — Part 1: Test method using liquid scintillation counting
This document specifies the determination of nickel-59 and nickel-63 (59Ni and 63Ni) activity concentration in samples of all types of water using liquid scintillation counting (LSC). Using currently available liquid scintillation counters, this test method can measure 59Ni activity concentrations of 50 mBq·l−1 and 63Ni activity concentrations of 20 mBq·l−1 with a counting time of 200 min and a sample volume of 1,5 l. NOTE These performance indicators are wholly dependent on the measurement regimes in individual laboratories; in particular, the detection limits for 59Ni are entirely dependent on the levels of 63Ni that can be present. The range of application depends on the amount of dissolved material in the water and on the performance characteristics of the measurement equipment (background count rate and detection efficiency). It is the laboratory’s responsibility to ensure the suitability of this test method for the water samples tested.
Qualité de l'eau — Nickel 59 et Nickel 63 — Partie 1: Méthode d'essai par comptage des scintillations en milieu liquide
Le présent document spécifie la détermination de l’activité volumique du nickel-59 et du nickel-63 (59Ni et 63Ni) dans des échantillons de tous types d’eau, par comptage des scintillations en milieu liquide. Avec les compteurs à scintillations en milieu liquide actuellement disponibles, cette méthode d’essai peut mesurer des activités volumiques de 50 mBq·l−1 pour le 59Ni et des activités volumiques de 20 mBq·l−1 pour le 63Ni, avec une durée de comptage de 200 min et un volume d’échantillon de 1,5 l. NOTE Ces indicateurs de performance dépendent entièrement des régimes de mesure de chaque laboratoire; plus particulièrement, les limites de détection du 59Ni sont totalement dépendantes des niveaux de 63Ni susceptibles d’être présents. Le domaine d’application de la méthode dépend de la quantité de matière dissoute dans l’eau et des caractéristiques de performance de l’équipement de mesure (taux de comptage du bruit de fond et rendement de détection). Il incombe au laboratoire de s’assurer de la pertinence de la présente méthode d’essai pour les échantillons d’eau soumis à essai.
General Information
Standards Content (Sample)
INTERNATIONAL ISO
STANDARD 23655-1
First edition
2022-09
Water quality — Nickel-59 and
nickel-63 —
Part 1:
Test method using liquid scintillation
counting
Qualité de l'eau — Nickel 59 et Nickel 63 —
Partie 1: Méthode d'essai par comptage des scintillations en milieu
liquide
Reference number
© ISO 2022
All rights reserved. Unless otherwise specified, or required in the context of its implementation, no part of this publication may
be reproduced or utilized otherwise in any form or by any means, electronic or mechanical, including photocopying, or posting on
the internet or an intranet, without prior written permission. Permission can be requested from either ISO at the address below
or ISO’s member body in the country of the requester.
ISO copyright office
CP 401 • Ch. de Blandonnet 8
CH-1214 Vernier, Geneva
Phone: +41 22 749 01 11
Email: copyright@iso.org
Website: www.iso.org
Published in Switzerland
ii
Contents Page
Foreword .iv
Introduction .v
1 Scope . 1
2 Normative references . 1
3 Terms and definitions . 1
4 General symbols and nickel-59 and nickel-63 specific symbols . 2
5 Principle . 4
6 Reagents . 4
6.1 Standard solutions . 5
6.1.1 Nickel-59 and Ni standards . 5
6.1.2 Stable nickel standards . 5
6.2 Chemical quenching agent . 5
6.3 Colour quenching agent . 5
6.4 Holdback carrier . 5
6.5 Water . 5
6.6 Specific reagents for chemical separation . 5
7 Equipment . 6
7.1 Laboratory equipment for direct evaporation . 6
7.2 Liquid scintillation vials . . 6
7.3 Measurement equipment: Liquid scintillation counter . 6
8 Sampling . 6
9 Liquid scintillation set up and calibration . 7
9.1 Window setting . 7
9.2 Background . 7
9.3 Calibration . 7
10 Procedure .9
10.1 Preliminary . 9
10.1.1 Stable nickel content . 9
10.1.2 Iron and nickel separation . 9
10.2 Liquid scintillation source preparation. 9
11 Quality control .10
12 Expression of results .10
12.1 Nickel-59 measurements . 10
12.1.1 Nickel recovery . 10
12.1.2 Activity calculation . 10
12.2 Nickel-63 measurements . 11
12.3 Uncertainties and characteristic limits . 11
12.3.1 Nickel recovery . 11
12.3.2 Nickel-59 measurements . 11
12.3.3 Nickel-63 measurements . 13
12.4 Limits of the coverage interval .15
12.4.1 Limits of the probabilistically symmetric coverage interval .15
12.4.2 Shortest coverage interval . 16
13 Test report .16
Annex A (normative) Isolation and purification of nickel .18
Bibliography .20
iii
Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards
bodies (ISO member bodies). The work of preparing International Standards is normally carried out
through ISO technical committees. Each member body interested in a subject for which a technical
committee has been established has the right to be represented on that committee. International
organizations, governmental and non-governmental, in liaison with ISO, also take part in the work.
ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of
electrotechnical standardization.
The procedures used to develop this document and those intended for its further maintenance are
described in the ISO/IEC Directives, Part 1. In particular, the different approval criteria needed for the
different types of ISO documents should be noted. This document was drafted in accordance with the
editorial rules of the ISO/IEC Directives, Part 2 (see www.iso.org/directives).
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. ISO shall not be held responsible for identifying any or all such patent rights. Details of
any patent rights identified during the development of the document will be in the Introduction and/or
on the ISO list of patent declarations received (see www.iso.org/patents).
Any trade name used in this document is information given for the convenience of users and does not
constitute an endorsement.
For an explanation of the voluntary nature of standards, the meaning of ISO specific terms and
expressions related to conformity assessment, as well as information about ISO's adherence to
the World Trade Organization (WTO) principles in the Technical Barriers to Trade (TBT), see
www.iso.org/iso/foreword.html.
This document was prepared by Technical Committee ISO/TC 147, Water quality, Subcommittee SC 3,
Radioactivity measurements.
A list of all the parts in the ISO 23655 series can be found on the ISO website.
Any feedback or questions on this document should be directed to the user’s national standards body. A
complete listing of these bodies can be found at www.iso.org/members.html.
iv
Introduction
Radioactivity from several naturally-occurring and anthropogenic sources is present throughout
the environment. Thus, water bodies (e.g. surface waters, ground waters, sea waters) can contain
radionuclides of natural, human-made or both origins:
40 3 14
— natural radionuclides, including K, H, C, and those originating from the thorium and uranium
226 228 234 238 210 210
decay series, in particular Ra, Ra, U, U, Po and Pb can be found in water for
natural reasons (e.g. desorption from the soil and washoff by rain water) or can be released from
technological processes involving naturally occurring radioactive materials (e.g. the mining and
processing of mineral sands or phosphate fertilizers production and use);
— human-made radionuclides such as transuranium elements (americium, plutonium, neptunium,
3 14 90
curium), H, C, Sr, and gamma emitting radionuclides can also be found in natural waters.
Small quantities of these radionuclides are discharged from nuclear fuel cycle facilities into the
environment as a result of authorized routine releases. Some of these radionuclides used for
medical and industrial applications are also released into the environment after use. Anthropogenic
radionuclides are also found in waters as a result of past fallout contaminations resulting from
the explosion in the atmosphere of nuclear devices and accidents such as those that occurred in
Chernobyl and Fukushima.
Radionuclide activity concentration in water bodies can vary according to local geological
characteristics and climatic conditions and can be locally and temporally enhanced by releases from
[1]
nuclear installation during planned, existing and emergency exposure situations . Drinking-water can
thus contain radionuclides at activity concentrations which can present a risk to human health.
The radionuclides present in liquid effluents are usually controlled before being discharged into
[2]
the environment and water bodies. Drinking waters are monitored for their radioactivity as
[3]
recommended by the World Health Organization (WHO) so that proper actions can be taken to ensure
that there is no adverse health effect to the public. Following these international recommendations,
national regulations usually specify radionuclide authorized concentration limits for liquid effluent
discharged to the environment and radio
...
NORME ISO
INTERNATIONALE 23655-1
Première édition
2022-09
Qualité de l'eau — Nickel 59 et Nickel
63 —
Partie 1:
Méthode d'essai par comptage des
scintillations en milieu liquide
Water quality — Nickel-59 and nickel-63 —
Part 1: Test method using liquid scintillation counting
Numéro de référence
DOCUMENT PROTÉGÉ PAR COPYRIGHT
© ISO 2022
Tous droits réservés. Sauf prescription différente ou nécessité dans le contexte de sa mise en œuvre, aucune partie de cette
publication ne peut être reproduite ni utilisée sous quelque forme que ce soit et par aucun procédé, électronique ou mécanique,
y compris la photocopie, ou la diffusion sur l’internet ou sur un intranet, sans autorisation écrite préalable. Une autorisation peut
être demandée à l’ISO à l’adresse ci-après ou au comité membre de l’ISO dans le pays du demandeur.
ISO copyright office
Case postale 401 • Ch. de Blandonnet 8
CH-1214 Vernier, Genève
Tél.: +41 22 749 01 11
E-mail: copyright@iso.org
Web: www.iso.org
Publié en Suisse
ii
Sommaire Page
Avant-propos .iv
Introduction .v
1 Domaine d’application . 1
2 Références normatives .1
3 Termes et définitions . 2
4 Symboles généraux et symboles spécifiques du nickel 59 et du nickel 63 .2
5 Principe. 4
6 Réactifs . 5
6.1 Solutions étalons . 5
59 63
6.1.1 Étalons de Ni et Ni . 5
6.1.2 Étalons de nickel stable . 5
6.2 Agent de quenching chimique . 5
6.3 Agent de quenching de couleur . 5
6.4 Entraîneur de rétention . 5
6.5 Eau . 5
6.6 Réactifs spécifiques pour la séparation chimique . 5
7 Équipement . 6
7.1 Équipement de laboratoire pour évaporation directe . 6
7.2 Flacons de scintillation liquide . 6
7.3 Équipement de mesure: compteur à scintillations en milieu liquide . 6
8 Échantillonnage .7
9 Mise en place et étalonnage des scintillations en milieu liquide .7
9.1 Définition de la fenêtre . 7
9.2 Bruit de fond . 7
9.3 Étalonnage . 7
10 Mode opératoire . 9
10.1 Préliminaire . 9
10.1.1 Teneur en nickel stable . 9
10.1.2 Séparation du fer et du nickel . 9
10.2 Préparation de la source de scintillation en milieu liquide . 10
11 Contrôle de la qualité .10
12 Expression des résultats .10
12.1 Mesurages du Ni . 10
12.1.1 Rendement en nickel . 10
12.1.2 Calcul d’activité . 11
12.2 Mesurages du Ni . 11
12.3 Incertitudes et limites caractéristiques . 11
12.3.1 Rendement en nickel . 11
12.3.2 Mesurages du Ni .12
12.3.3 Mesurages du Ni . 13
12.4 Limites des intervalles élargis . 15
12.4.1 Limites de l’intervalle élargi probabilistiquement symétrique .15
12.4.2 Intervalle élargi le plus court . 15
13 Rapport d’essai .16
Annexe A (normative) Séparation et purification du nickel .18
Bibliographie .20
iii
Avant-propos
L’ISO (Organisation internationale de normalisation) est une fédération mondiale d’organismes
nationaux de normalisation (comités membres de l’ISO). L’élaboration des Normes internationales est
en général confiée aux comités techniques de l’ISO. Chaque comité membre intéressé par une étude
a le droit de faire partie du comité technique créé à cet effet. Les organisations internationales,
gouvernementales et non gouvernementales, en liaison avec l’ISO participent également aux travaux.
L’ISO collabore étroitement avec la Commission électrotechnique internationale (IEC) en ce qui
concerne la normalisation électrotechnique.
Les procédures utilisées pour élaborer le présent document et celles destinées à sa mise à jour sont
décrites dans les Directives ISO/IEC, Partie 1. Il convient, en particulier de prendre note des différents
critères d’approbation requis pour les différents types de documents ISO. Le présent document
a été rédigé conformément aux règles de rédaction données dans les Directives ISO/IEC, Partie 2
(voir www.iso.org/directives).
L’attention est attirée sur le fait que certains des éléments du présent document peuvent faire l’objet de
droits de propriété intellectuelle ou de droits analogues. L’ISO ne saurait être tenue pour responsable
de ne pas avoir identifié de tels droits de propriété et averti de leur existence. Les détails concernant
les références aux droits de propriété intellectuelle ou autres droits analogues identifiés lors de
l’élaboration du document sont indiqués dans l’Introduction et/ou dans la liste des déclarations de
brevets reçues par l’ISO (voir www.iso.org/brevets).
Les appellations commerciales éventuellement mentionnées dans le présent document sont données
pour information, par souci de commodité, à l’intention des utilisateurs et ne sauraient constituer un
engagement.
Pour une explication de la nature volontaire des normes, la signification des termes et expressions
spécifiques de l’ISO liés à l’évaluation de la conformité, ou pour toute information au sujet de l’adhésion
de l’ISO aux principes de l’Organisation mondiale du commerce (OMC) concernant les obstacles
techniques au commerce (OTC), voir le lien suivant: www.iso.org/iso/fr/avant-propos.
Le présent document a été élaboré par le comité technique ISO/TC 147, Qualité de l’eau, sous-comité
SC 3, Mesurages de la radioactivité.
Une liste de toutes les parties de la série ISO 23655 se trouve sur le site web de l’ISO.
Il convient que l’utilisateur adresse tout retour d’information ou toute question concernant le présent
document à l’organisme national de normalisation de son pays. Une liste exhaustive desdits organismes
se trouve à l’adresse www.iso.org/fr/members.html.
iv
Introduction
La radioactivité provenant de diverses sources naturelles et anthropogènes est présente partout dans
l’environnement. Par conséquent, les masses d’eau (par exemple, eaux de surface, eaux souterraines,
eaux de mer) peuvent contenir des radionucléides d’origine naturelle ou artificielle (c’est-à-dire
engendrée par l’homme), ou les deux:
40 3 14
— les radionucléides naturels, dont le K, le H, le C et ceux issus des chaînes de désintégration du
226 228 234 238 210 210
thorium et de l’uranium, notamment le Ra, le Ra, le U, le U, le Po et le Pb, peuvent
se trouver dans l’eau pour des raisons naturelles (par exemple, désorption du sol et lessivage
par les eaux pluviales) ou peuvent être libérés par des processus technologiques impliquant des
matériaux radioactifs existant à l’état naturel (par exemple, extraction minière et traitement de
sables minéraux ou production et utilisation d’engrais phosphatés);
— les radionucléides engendrés par l’activité humaine, tels que les éléments transuraniens (américium,
3 14 90
plutonium, neptunium, curium), le H, le C, le Sr et certains radionucléides émetteurs gamma
peuvent également être présents dans les eaux naturelles. De petites quantités de ces radionucléides
sont déversées dans l’environnement par les installations concernant le cycle du combustible
nucléaire en conséquence de leur libération périodique autorisée. Certains de ces radionucléides
utilisés dans le cadre d’applications médicales et industrielles sont également libérés dans
l’environnement après usage. Les radionucléides anthropogènes peuvent également se trouver dans
les eaux du fait de contaminations par retombées d’éléments radioactifs rejetés dans l’atmosphère
lors de l’explosion de dispositifs nucléaires ou lors d’accidents nucléaires, tels que ceux de Tchernobyl
et de Fukushima.
L’activité volumique des radionucléides dans les masses d’eau est variable en fonction des
caractéristiques géologiques et des conditions climatiques locales, et peut être renforcée localement
et dans le temp
...