Publication 60352-1 de la CEI IEC Publication 60352-1
(Troisième édition – 1997) (Third edition – 1997)
Connexions sans soudure – Solderless connections –
Partie 1: Connexions enroulées – Part 1: Wrapped connections –
Règles générales, méthodes d'essai General requirements, test methods
et guide pratique and practical guidance
CORRIGENDUM 1
Page 28 Page 29
Ne concerne que le texte anglais 4.5.3 Modified wrapped connection
In the second paragraph instead of:
The minimum number of stripped wires .
read:
The minimum number of turns of stripped
wires .
Table 8
Change the title of table 8 to read:
Table 8 – Minimum number of turns of
stripped wires
Table 8
Change the heading
...
This May Also Interest You
IEC 60352-2:2024 is applicable to solderless crimped connections made with:
- appropriately designed uninsulated or pre-insulated crimp barrels as parts of crimp contacts, terminal ends or splices, and
- stranded wires of 0,05 mm2 to 10 mm2 cross-section or
- solid wires of 0,25 mm to 3,6 mm diameter;
for use in electrical and electronic equipment.
Information on the materials and data from industrial experience is included in addition to the test procedures to provide electrically stable connections under prescribed environmental conditions.
This part of IEC 60352 is not applicable to crimping of coaxial cables.
This part of IEC 60352 determines the suitability of solderless crimped connections as described above, under specified mechanical, electrical and atmospheric conditions and provides a means of comparing test results when the tools used to make the connections are of different designs or manufacture.
- Standard260 pagesEnglish and French languagesale 15% off
IEC 60352-9:2024 provides guidelines for welding and testing of ultrasonically welded connections and includes requirements, tests and practical guidance information.
Ultrasonic welding is a form of cold friction welding that is becoming increasingly popular in many industries. This type of welding uses ultrasonic vibration to join materials together, creating a bond that is both strong and reliable. Ultrasonic welding has been identified as a process in ISO 4063-41 by the International Organization for Standardization (ISO).
The process of ultrasonic welding relies on high frequency ultrasound waves being used to create frictional heat at the connection point. High temperature is not required for this special method of welding, making it one of the most cost-effective ways to join two materials together.
It also requires fewer steps than traditional methods, meaning it can be completed quickly and with minimal resources.
Ultrasonic welding has been around for decades but only recently has become more widely utilized due to advances in technology and its availability at lower cost. It can be used on many different materials including plastics, rubbers, metals, textiles, and composites. Due to its precision and strong bonds it creates, it has become extremely popular in manufacturing processes such as automotive industry, electronics industry, furniture production and even medical device production.
This document covers ultrasonically welded connections made with stranded or flexible wires (class 2, 5 or 6 per IEC 60228) of copper or copper alloy, as well as of aluminium or aluminium alloy. These welded metal-to-metal connections shall employ wires with cross-sectional area of 0,08 mm2 to 160 mm2 and shall not exceed a total cross-sectional area, in case of wire bundle, of 200 mm2. For aluminium or aluminium alloy wires, the minimum required cross-sectional area is 2,5 mm2.
Additionally, information on materials, data from industrial experience and test procedures are included to ensure electrically stable connections under prescribed environmental conditions.
Lastly, this document aims to achieve comparable results when using ultrasonic welding equipment with similar performance and specifications as specified by the termination manufacturer.
- Standard138 pagesEnglish and French languagesale 15% off
IEC 60352-6:2022 This part of IEC 60352 is applicable to insulation piercing connections made with stranded wires and tinsel wires, insulated flat conductors and flat flexible circuitries for use in electrical and electronic equipment. Information on materials and data from industrial experience is included in addition to the test procedures to provide electrically stable connections under prescribed environmental conditions. The object of this document is to: determine the suitability of insulation piercing connections under specified mechanical, electrical, and atmospheric conditions; provide a means of comparing test results when the tools used to make the connections, if any, are of different designs or manufacture.
- Standard70 pagesEnglish and French languagesale 15% off
IEC 60352-4:2020 is applicable to non-accessible ID connections for which the tests and measurements according to Clauses 6 through 8 are suitable and which are made with: – appropriately designed ID terminations; – wires having solid round conductors of 0,25 mm to 3,6 mm nominal diameter; – wires having stranded conductors of 0,05 mm2 to 10 mm2 cross-sectional area; for use in electrical and electronic equipment and components. Information on materials and data from industrial experience is included in addition to the test procedures to provide electrically stable connections under prescribed environmental conditions. There are different designs and materials for ID terminations in use. For this reason, only fundamental parameters of the termination are specified, while the performance requirements of the wire and the complete connection are specified in full detail. The purpose of this document is: – to determine the suitability of non-accessible ID connections under specified mechanical, electrical and atmospheric conditions; – to provide a means of comparing test results when the tools used to make the connections, if any, are of different designs or manufacture. This second edition cancels and replaces the first edition, published in 1994, and its Amendment 1 (2000). This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) Transferred Clauses 9 to 13 into Annex A (informative). b) The figures were re-drawn for clarity.
- Standard85 pagesEnglish and French languagesale 15% off
IEC 60352-3:2020 est applicable aux connexions CAD qui sont accessibles pour les essais et les mesures conformes aux Articles 6 à 8 et qui sont composées de: – contacts CAD accessibles de conception appropriée, – fils à conducteurs cylindriques massifs de diamètre nominal 0,25 mm à 3,6 mm, – fils à conducteurs divisés de section 0,05 mm2 à 10 mm2, pour l’utilisation dans les équipements et composants électriques et électroniques. Des informations sur les matières et des résultats dus à l’expérience industrielle y sont inclus en plus des méthodes d’essai pour assurer des connexions électriquement stables dans les conditions d’environnement prescrites. Il y a différentes conceptions et matières utilisées pour les contacts CAD accessibles. C’est pourquoi seuls les paramètres fondamentaux du contact sont spécifiés, tandis que les exigences des performances du fil et de la connexion terminée sont définies dans tous les détails. Le présent document a pour objet de: – déterminer la conformité des connexions CAD accessibles dans des conditions méca-niques, électriques et atmosphériques spécifiées; – fournir un moyen de comparaison des résultats d’essai quand les outils utilisés pour faire les connexions, le cas échéant, sont de conceptions ou de fabrications diffé-rentes. Cette deuxième édition annule et remplace la première édition parue en 1993. Cette édi-tion constitue une révision technique. Cette édition inclut les modifications techniques majeures suivantes par rapport à l'édi-tion précédente: a) Paragraphe 7.2.2: il réduit la limite de la durée de la perturbation de contact à 1 µs. b) Paragraphe 7.2.3: il réduit la limite de la durée de la perturbation de contact à 1 µs. c) Les Articles 9 à 13 ont été transférés à l’Annexe A (informative). d) Les figures ont été révisées pour plus de clarté.
- Standard81 pagesEnglish and French languagesale 15% off
Is applicable to solderless press-in connections for use in telecommunication equipment and in electronic devices employing similar techniques. Determines the suitability of press-in connections under specified mechanical, electrical and atmospheric conditions.
- Standard69 pagesEnglish and French languagesale 15% off
- Standard69 pagesEnglish and French languagesale 15% off
- Standard37 pagesEnglish and French languagesale 15% off
Determines the suitability of insulation piercing connections under specified mechanical, electrical and atmospheric conditions, and provides a means of comparing test results when the tools used to make the connections are of different design.
- Standard53 pagesEnglish and French languagesale 15% off
Determines the suitability of wrapped connections under specified mechanical, electrical and atmospheric conditions, and provides a means of comparing test results when the tools used to make the connections are of different design. The contents of the corrigendum of October 1998 have been included in this copy.