Environmental Engineering (EE); Environmental conditions and environmental tests for telecommunications equipment; Part 1: Classification of environmental conditions; Sub-part 4: Stationary use at non-weatherprotected locations

REN/EE-017014

Okoljski inženiring (EE) - Okoljski pogoji in preskusi vplivov okolja na telekomunikacijsko opremo - 1. del: Klasifikacija okoljskih pogojev - 4. poddel: Fiksna uporaba na lokacijah, ki niso zaščitene pred vremenskimi vplivi

General Information

Status
Not Published
Current Stage
12 - Citation in the OJ (auto-insert)
Due Date
27-May-2026
Completion Date
19-May-2026
Mandate
M/462

Buy Documents

Standard

ETSI EN 300 019-1-4 V3.1.0 (2026-02) - Environmental Engineering (EE); Environmental conditions and environmental tests for telecommunications equipment; Part 1: Classification of environmental conditions; Sub-part 4: Stationary use at non-weatherprotected locations

English language (20 pages)
sale 15% off
Preview
sale 15% off
Preview
Standard

ETSI EN 300 019-1-4 V3.1.1 (2026-05) - Environmental Engineering (EE); Environmental conditions and environmental tests for telecommunications equipment; Part 1: Classification of environmental conditions; Sub-part 4: Stationary use at non-weatherprotected locations

English language (20 pages)
sale 15% off
Preview
sale 15% off
Preview
Draft

prEN 300 019-1-4 V3.1.0:2026

English language (20 pages)
Preview
Preview
e-Library read for
1 day

Buy Documents

Standard

ETSI EN 300 019-1-4 V3.1.0 (2026-02) - Environmental Engineering (EE); Environmental conditions and environmental tests for telecommunications equipment; Part 1: Classification of environmental conditions; Sub-part 4: Stationary use at non-weatherprotected locations

English language (20 pages)
sale 15% off
Preview
sale 15% off
Preview
Standard

ETSI EN 300 019-1-4 V3.1.1 (2026-05) - Environmental Engineering (EE); Environmental conditions and environmental tests for telecommunications equipment; Part 1: Classification of environmental conditions; Sub-part 4: Stationary use at non-weatherprotected locations

English language (20 pages)
sale 15% off
Preview
sale 15% off
Preview
Draft

prEN 300 019-1-4 V3.1.0:2026

English language (20 pages)
Preview
Preview
e-Library read for
1 day

Frequently Asked Questions

ETSI EN 300 019-1-4 V3.1.1 (2026-05) is a standard published by the European Telecommunications Standards Institute (ETSI). Its full title is "Environmental Engineering (EE); Environmental conditions and environmental tests for telecommunications equipment; Part 1: Classification of environmental conditions; Sub-part 4: Stationary use at non-weatherprotected locations". This standard covers: REN/EE-017014

REN/EE-017014

ETSI EN 300 019-1-4 V3.1.1 (2026-05) is associated with the following European legislation: Standardization Mandates: M/462. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.

ETSI EN 300 019-1-4 V3.1.1 (2026-05) is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)


Draft ETSI EN 300 019-1-4 V3.1.0 (2026-02)

EUROPEAN STANDARD
Environmental Engineering (EE);
Environmental conditions and environmental tests
for telecommunications equipment;
Part 1: Classification of environmental conditions;
Sub-part 4: Stationary use at non-weatherprotected locations

2 Draft ETSI EN 300 019-1-4 V3.1.0 (2026-02)

Reference
REN/EE-017014
Keywords
environment, equipment practice, testing
ETSI
650 Route des Lucioles
F-06921 Sophia Antipolis Cedex - FRANCE

Tel.: +33 4 92 94 42 00  Fax: +33 4 93 65 47 16

Siret N° 348 623 562 00017 - APE 7112B
Association à but non lucratif enregistrée à la
Sous-Préfecture de Grasse (06) N° w061004871

Important notice
The present document can be downloaded from the
ETSI Search & Browse Standards application.
The present document may be made available in electronic versions and/or in print. The content of any electronic and/or
print versions of the present document shall not be modified without the prior written authorization of ETSI. In case of any
existing or perceived difference in contents between such versions and/or in print, the prevailing version of an ETSI
deliverable is the one made publicly available in PDF format on ETSI deliver repository.
Users should be aware that the present document may be revised or have its status changed,
this information is available in the Milestones listing.
If you find errors in the present document, please send your comments to
the relevant service listed under Committee Support Staff.
If you find a security vulnerability in the present document, please report it through our
Coordinated Vulnerability Disclosure (CVD) program.
Notice of disclaimer & limitation of liability
The information provided in the present deliverable is directed solely to professionals who have the appropriate degree of
experience to understand and interpret its content in accordance with generally accepted engineering or
other professional standard and applicable regulations.
No recommendation as to products and services or vendors is made or should be implied.
In no event shall ETSI be held liable for loss of profits or any other incidental or consequential damages.

Any software contained in this deliverable is provided "AS IS" with no warranties, express or implied, including but not
limited to, the warranties of merchantability, fitness for a particular purpose and non-infringement of intellectual property
rights and ETSI shall not be held liable in any event for any damages whatsoever (including, without limitation, damages
for loss of profits, business interruption, loss of information, or any other pecuniary loss) arising out of or related to the use
of or inability to use the software.
Copyright Notification
No part may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and
microfilm except as authorized by written permission of ETSI.
The content of the PDF version shall not be modified without the written authorization of ETSI.
The copyright and the foregoing restriction extend to reproduction in all media.

© ETSI 2026.
All rights reserved.
ETSI
3 Draft ETSI EN 300 019-1-4 V3.1.0 (2026-02)
Contents
Intellectual Property Rights . 4
Foreword . 4
Modal verbs terminology . 5
1 Scope . 6
2 References . 6
2.1 Normative references . 6
2.2 Informative references . 6
3 Definition of terms, symbols and abbreviations . 7
3.1 Terms . 7
3.2 Symbols . 7
3.3 Abbreviations . 7
4 Environmental classes . 7
4.0 General . 7
4.1 Class 4.10: sheltered non-weatherprotected locations in tropical, arid, temperate, and cold climatic
classification . 8
4.1.0 Class 4.10 full temperature range . 8
4.1.1 Class 4.10L: sheltered non-weatherprotected locations in cold climatic classification . 8
4.1.2 Class 4.10H: sheltered non-weatherprotected locations in tropical, arid, temperate climatic
classification . 9
4.2 Class 4.11: Open-air non-weatherprotected locations in the tropical climatic . 10
4.3 Class 4.12: Open-air non-weatherprotected locations in the arid and temperate climatic classification . 10
4.4 Class 4.13: Open-air non-weatherprotected locations in the cold and polar climatic classifications . 11
5 Environmental conditions. 12
5.1 Climatic conditions. 12
5.2 Biological conditions . 13
5.3 Chemically active substances . 13
5.4 Mechanically active substances . 15
5.5 Mechanical conditions . 15
5.6 Earthquake conditions . 15
Annex A (informative): Bibliography . 18
Annex B (informative): Change history . 19
History . 20

ETSI
4 Draft ETSI EN 300 019-1-4 V3.1.0 (2026-02)
Intellectual Property Rights
Essential patents
IPRs essential or potentially essential to normative deliverables may have been declared to ETSI. The declarations
pertaining to these essential IPRs, if any, are publicly available for ETSI members and non-members, and can be
found in ETSI SR 000 314: "Intellectual Property Rights (IPRs); Essential, or potentially Essential, IPRs notified to
ETSI in respect of ETSI standards", which is available from the ETSI Secretariat. Latest updates are available on the
ETSI IPR online database.
Pursuant to the ETSI Directives including the ETSI IPR Policy, no investigation regarding the essentiality of IPRs,
including IPR searches, has been carried out by ETSI. No guarantee can be given as to the existence of other IPRs not
referenced in ETSI SR 000 314 (or the updates on the ETSI Web server) which are, or may be, or may become,
essential to the present document.
Trademarks
The present document may include trademarks and/or tradenames which are asserted and/or registered by their owners.
ETSI claims no ownership of these except for any which are indicated as being the property of ETSI, and conveys no
right to use or reproduce any trademark and/or tradename. Mention of those trademarks in the present document does
not constitute an endorsement by ETSI of products, services or organizations associated with those trademarks.
DECT™, PLUGTESTS™, UMTS™ and the ETSI logo are trademarks of ETSI registered for the benefit of its
Members. 3GPP™, LTE™ and 5G™ logo are trademarks of ETSI registered for the benefit of its Members and of the
3GPP Organizational Partners. oneM2M™ logo is a trademark of ETSI registered for the benefit of its Members and of ®
the oneM2M Partners. GSM and the GSM logo are trademarks registered and owned by the GSM Association.
Foreword
This draft European Standard (EN) has been produced by ETSI Technical Committee Environmental Engineering (EE),
and is now submitted for the combined Public Enquiry and Vote phase of the ETSI.
The present document is part 1, sub-part 4 of a multi-part deliverable covering the classification of environmental
conditions and environmental tests for telecommunications equipment, as identified below:
Part 1: "Classification of environmental conditions": (see note 1)
Sub-part 0: "Introduction";
Sub-part 1: "Storage";
Sub-part 2: "Transportation";
Sub-part 3: "Stationary use at weatherprotected locations";
Sub-part 4: "Stationary use at non-weatherprotected locations";
Sub-part 5: "Ground vehicle installations";
Sub-part 6: "Ship environments";
Sub-part 7: "Portable and non-stationary use";
Sub-part 8: "Stationary use at underground locations";
Part 2: "Specification of environmental tests" (see note 2).
NOTE 1: Specifies different standardized environmental classes covering climatic and biological conditions,
chemically and mechanically active substances and mechanical conditions during storage, transportation
and in use. Sub-part 1-0 forms a general overview of part 1.
NOTE 2: Specifies the recommended test severities and test methods for the different environmental classes.
ETSI
5 Draft ETSI EN 300 019-1-4 V3.1.0 (2026-02)

Proposed national transposition dates
Date of latest announcement of this EN (doa): 3 months after ETSI publication
Date of latest publication of new National Standard
or endorsement of this EN (dop/e): 6 months after doa
Date of withdrawal of any conflicting National Standard (dow): 6 months after doa

Modal verbs terminology
In the present document "shall", "shall not", "should", "should not", "may", "need not", "will", "will not", "can" and
"cannot" are to be interpreted as described in clause 3.2 of the ETSI Drafting Rules (Verbal forms for the expression of
provisions).
"must" and "must not" are NOT allowed in ETSI deliverables except when used in direct citation.
ETSI
6 Draft ETSI EN 300 019-1-4 V3.1.0 (2026-02)
1 Scope
The purpose of the present document is to define a class of environmental conditions and their severities to which
equipment may be exposed. Only severe conditions, which may be harmful to the equipment, are included. The
severities specified are those which will have a low probability of being exceeded; generally less than 1 % of the
operating time in a year.
The present document applies to equipment mounted for stationary use including periods of erection work, down time,
maintenance and repair at non-weatherprotected locations defined in clause 5.
2 References
2.1 Normative references
References are either specific (identified by date of publication and/or edition number or version number) or
non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the
referenced document (including any amendments) applies.
Referenced documents which are not found to be publicly available in the expected location might be found in the
ETSI docbox.
NOTE: While any hyperlinks included in this clause were valid at the time of publication, ETSI cannot guarantee
their long-term validity.
The following referenced documents are necessary for the application of the present document.
[1] ETSI EN 300 019-1-3: "Environmental Engineering (EE); Environmental conditions and
environmental tests for telecommunications equipment; Part 1: Classification of environmental
conditions; Sub-part 3: Stationary use at weatherprotected locations".
2.2 Informative references
References are either specific (identified by date of publication and/or edition number or version number) or
non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the
referenced document (including any amendments) applies.
NOTE: While any hyperlinks included in this clause were valid at the time of publication, ETSI cannot guarantee
their long-term validity.
The following referenced documents may be useful in implementing an ETSI deliverable or add to the reader's
understanding, but are not required for conformance to the present document.
[i.1] Void.
[i.2] IEC 60721-3-4:2019: "Classification of environmental conditions - Part 3-4: Classification of
groups of environmental parameters and their severities - Stationary use at non-weatherprotected
locations".
[i.3] Void.
[i.4] ISO 9223:2012: "Corrosion of metals and alloys — Corrosivity of atmospheres — Classification,
determination and estimation".
[i.5] IEC 60721-2-6:2022: "Classification of environmental conditions - Part 2-6: Environmental
conditions appearing in nature - Earthquake vibration and shock".
[i.6] IEC 60068-3-3:2019: "Environmental testing - Part 3-3: Supporting documentation and guidance -
Seismic test methods for equipment".
ETSI
7 Draft ETSI EN 300 019-1-4 V3.1.0 (2026-02)
3 Definition of terms, symbols and abbreviations
3.1 Terms
For the purposes of the present document, the following terms apply:
absolute humidity: mass of water vapour in grammes which is associated with one cubic metre of dry air in an
air/water vapour mixture
non-weatherprotected location: location at which the equipment is not protected from direct weather influences
relative humidity: ratio of the partial pressure of the water vapour in moist air at a given temperature, to the partial
pressure of the water vapour in saturated air at the same temperature
sheltered location: location at which a product is covered by a structure to protect it from direct meteorological
conditions, i.e. direct sunlight, heavy rain
stationary use: use of the equipment mounted firmly on the structure, or on mounting devices, or it is permanently
placed at a certain site
NOTE: It is not intended for portable use - but short periods of handling during erection works, down time,
maintenance and repair at the location are included.
3.2 Symbols
Void.
3.3 Abbreviations
For the purposes of the present document, the following abbreviations apply:
RS Response Spectrum
UV UltraViolet
ZPA Zero Period Acceleration
4 Environmental classes
4.0 General
The classes shown in parentheses, e.g. (C3), may be selected for special applications.
These classes shall apply to a non-weatherprotected location.
These classes shall apply to locations:
• which are directly exposed to an open-air climate, including solar radiation, movement of the surrounding air,
precipitation and water jets; splashing water;
• where mould growth, or attacks by animals but excluding termites, may occur;
• with normal levels of contaminants experienced in urban areas with industrial activities scattered over the
whole area and/or with heavy traffic. It also applies to coastal areas;
NOTE 1: At locations in the immediate neighbourhood of industrial sources with chemical emissions either special
precautions should be taken or a special chemical class should be chosen.
ETSI
8 Draft ETSI EN 300 019-1-4 V3.1.0 (2026-02)
• in
...


EUROPEAN STANDARD
Environmental Engineering (EE);
Environmental conditions and environmental tests
for telecommunications equipment;
Part 1: Classification of environmental conditions;
Sub-part 4: Stationary use at non-weatherprotected locations

2 ETSI EN 300 019-1-4 V3.1.1 (2026-05)

Reference
REN/EE-017014
Keywords
environment, equipment practice, testing
ETSI
650 Route des Lucioles
F-06921 Sophia Antipolis Cedex - FRANCE

Tel.: +33 4 92 94 42 00  Fax: +33 4 93 65 47 16

Siret N° 348 623 562 00017 - APE 7112B
Association à but non lucratif enregistrée à la
Sous-Préfecture de Grasse (06) N° w061004871

Important notice
The present document can be downloaded from the
ETSI Search & Browse Standards application.
The present document may be made available in electronic versions and/or in print. The content of any electronic and/or
print versions of the present document shall not be modified without the prior written authorization of ETSI. In case of any
existing or perceived difference in contents between such versions and/or in print, the prevailing version of an ETSI
deliverable is the one made publicly available in PDF format on ETSI deliver repository.
Users should be aware that the present document may be revised or have its status changed,
this information is available in the Milestones listing.
If you find errors in the present document, please send your comments to
the relevant service listed under Committee Support Staff.
If you find a security vulnerability in the present document, please report it through our
Coordinated Vulnerability Disclosure (CVD) program.
Notice of disclaimer & limitation of liability
The information provided in the present deliverable is directed solely to professionals who have the appropriate degree of
experience to understand and interpret its content in accordance with generally accepted engineering or
other professional standard and applicable regulations.
No recommendation as to products and services or vendors is made or should be implied.
In no event shall ETSI be held liable for loss of profits or any other incidental or consequential damages.

Any software contained in this deliverable is provided "AS IS" with no warranties, express or implied, including but not
limited to, the warranties of merchantability, fitness for a particular purpose and non-infringement of intellectual property
rights and ETSI shall not be held liable in any event for any damages whatsoever (including, without limitation, damages
for loss of profits, business interruption, loss of information, or any other pecuniary loss) arising out of or related to the use
of or inability to use the software.
Copyright Notification
No part may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and
microfilm except as authorized by written permission of ETSI.
The content of the PDF version shall not be modified without the written authorization of ETSI.
The copyright and the foregoing restriction extend to reproduction in all media.

© ETSI 2026.
All rights reserved.
ETSI
3 ETSI EN 300 019-1-4 V3.1.1 (2026-05)
Contents
Intellectual Property Rights . 4
Foreword . 4
Modal verbs terminology . 5
1 Scope . 6
2 References . 6
2.1 Normative references . 6
2.2 Informative references . 6
3 Definition of terms, symbols and abbreviations . 7
3.1 Terms . 7
3.2 Symbols . 7
3.3 Abbreviations . 7
4 Environmental classes . 7
4.0 General . 7
4.1 Class 4.10: sheltered non-weatherprotected locations in tropical, arid, temperate, and cold climatic
classification . 8
4.1.0 Class 4.10 full temperature range . 8
4.1.1 Class 4.10L: sheltered non-weatherprotected locations in cold climatic classification . 8
4.1.2 Class 4.10H: sheltered non-weatherprotected locations in tropical, arid, temperate climatic
classification . 9
4.2 Class 4.11: Open-air non-weatherprotected locations in the tropical climatic . 10
4.3 Class 4.12: Open-air non-weatherprotected locations in the arid and temperate climatic classification . 10
4.4 Class 4.13: Open-air non-weatherprotected locations in the cold and polar climatic classifications . 11
5 Environmental conditions. 12
5.1 Climatic conditions. 12
5.2 Biological conditions . 13
5.3 Chemically active substances . 13
5.4 Mechanically active substances . 15
5.5 Mechanical conditions . 15
5.6 Earthquake conditions . 15
Annex A (informative): Bibliography . 18
Annex B (informative): Change history . 19
History . 20

ETSI
4 ETSI EN 300 019-1-4 V3.1.1 (2026-05)
Intellectual Property Rights
Essential patents
IPRs essential or potentially essential to normative deliverables may have been declared to ETSI. The declarations
pertaining to these essential IPRs, if any, are publicly available for ETSI members and non-members, and can be
found in ETSI SR 000 314: "Intellectual Property Rights (IPRs); Essential, or potentially Essential, IPRs notified to
ETSI in respect of ETSI standards", which is available from the ETSI Secretariat. Latest updates are available on the
ETSI IPR online database.
Pursuant to the ETSI Directives including the ETSI IPR Policy, no investigation regarding the essentiality of IPRs,
including IPR searches, has been carried out by ETSI. No guarantee can be given as to the existence of other IPRs not
referenced in ETSI SR 000 314 (or the updates on the ETSI Web server) which are, or may be, or may become,
essential to the present document.
Trademarks
The present document may include trademarks and/or tradenames which are asserted and/or registered by their owners.
ETSI claims no ownership of these except for any which are indicated as being the property of ETSI, and conveys no
right to use or reproduce any trademark and/or tradename. Mention of those trademarks in the present document does
not constitute an endorsement by ETSI of products, services or organizations associated with those trademarks.
DECT™, PLUGTESTS™, UMTS™ and the ETSI logo are trademarks of ETSI registered for the benefit of its
Members. 3GPP™, LTE™ and 5G™ logo are trademarks of ETSI registered for the benefit of its Members and of the
3GPP Organizational Partners. oneM2M™ logo is a trademark of ETSI registered for the benefit of its Members and of ®
the oneM2M Partners. GSM and the GSM logo are trademarks registered and owned by the GSM Association.
Foreword
This European Standard (EN) has been produced by ETSI Technical Committee Environmental Engineering (EE).
The present document is part 1, sub-part 4 of a multi-part deliverable covering the classification of environmental
conditions and environmental tests for telecommunications equipment, as identified below:
Part 1: "Classification of environmental conditions": (see note 1)
Sub-part 0: "Introduction";
Sub-part 1: "Storage";
Sub-part 2: "Transportation";
Sub-part 3: "Stationary use at weatherprotected locations";
Sub-part 4: "Stationary use at non-weatherprotected locations";
Sub-part 5: "Ground vehicle installations";
Sub-part 6: "Ship environments";
Sub-part 7: "Portable and non-stationary use";
Sub-part 8: "Stationary use at underground locations";
Part 2: "Specification of environmental tests" (see note 2).
NOTE 1: Specifies different standardized environmental classes covering climatic and biological conditions,
chemically and mechanically active substances and mechanical conditions during storage, transportation
and in use. Sub-part 1-0 forms a general overview of part 1.
NOTE 2: Specifies the recommended test severities and test methods for the different environmental classes.
ETSI
5 ETSI EN 300 019-1-4 V3.1.1 (2026-05)

National transposition dates
Date of adoption of this EN: 13 May 2026
Date of latest announcement of this EN (doa): 31 August 2026
Date of latest publication of new National Standard
or endorsement of this EN (dop/e): 28 February 2027
Date of withdrawal of any conflicting National Standard (dow): 28 February 2027

Modal verbs terminology
In the present document "shall", "shall not", "should", "should not", "may", "need not", "will", "will not", "can" and
"cannot" are to be interpreted as described in clause 3.2 of the ETSI Drafting Rules (Verbal forms for the expression of
provisions).
"must" and "must not" are NOT allowed in ETSI deliverables except when used in direct citation.
ETSI
6 ETSI EN 300 019-1-4 V3.1.1 (2026-05)
1 Scope
The purpose of the present document is to define a class of environmental conditions and their severities to which
equipment may be exposed. Only severe conditions, which may be harmful to the equipment, are included. The
severities specified are those which will have a low probability of being exceeded; generally less than 1 % of the
operating time in a year.
The present document applies to equipment mounted for stationary use including periods of erection work, down time,
maintenance and repair at non-weatherprotected locations defined in clause 5.
2 References
2.1 Normative references
References are either specific (identified by date of publication and/or edition number or version number) or
non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the
referenced document (including any amendments) applies.
Referenced documents which are not found to be publicly available in the expected location might be found in the
ETSI docbox.
NOTE: While any hyperlinks included in this clause were valid at the time of publication, ETSI cannot guarantee
their long-term validity.
The following referenced documents are necessary for the application of the present document.
[1] ETSI EN 300 019-1-3: "Environmental Engineering (EE); Environmental conditions and
environmental tests for telecommunications equipment; Part 1: Classification of environmental
conditions; Sub-part 3: Stationary use at weatherprotected locations".
2.2 Informative references
References are either specific (identified by date of publication and/or edition number or version number) or
non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the
referenced document (including any amendments) applies.
NOTE: While any hyperlinks included in this clause were valid at the time of publication, ETSI cannot guarantee
their long-term validity.
The following referenced documents may be useful in implementing an ETSI deliverable or add to the reader's
understanding, but are not required for conformance to the present document.
[i.1] Void.
[i.2] IEC 60721-3-4:2019: "Classification of environmental conditions - Part 3-4: Classification of
groups of environmental parameters and their severities - Stationary use at non-weatherprotected
locations".
[i.3] Void.
[i.4] ISO 9223:2012: "Corrosion of metals and alloys — Corrosivity of atmospheres — Classification,
determination and estimation".
[i.5] IEC 60721-2-6:2022: "Classification of environmental conditions - Part 2-6: Environmental
conditions appearing in nature - Earthquake vibration and shock".
[i.6] IEC 60068-3-3:2019: "Environmental testing - Part 3-3: Supporting documentation and guidance -
Seismic test methods for equipment".
ETSI
7 ETSI EN 300 019-1-4 V3.1.1 (2026-05)
3 Definition of terms, symbols and abbreviations
3.1 Terms
For the purposes of the present document, the following terms apply:
absolute humidity: mass of water vapour in grammes which is associated with one cubic metre of dry air in an
air/water vapour mixture
non-weatherprotected location: location at which the equipment is not protected from direct weather influences
relative humidity: ratio of the partial pressure of the water vapour in moist air at a given temperature, to the partial
pressure of the water vapour in saturated air at the same temperature
sheltered location: location at which a product is covered by a structure to protect it from direct meteorological
conditions, i.e. direct sunlight, heavy rain
stationary use: use of the equipment mounted firmly on the structure, or on mounting devices, or it is permanently
placed at a certain site
NOTE: It is not intended for portable use - but short periods of handling during erection works, down time,
maintenance and repair at the location are included.
3.2 Symbols
Void.
3.3 Abbreviations
For the purposes of the present document, the following abbreviations apply:
RS Response Spectrum
UV UltraViolet
ZPA Zero Period Acceleration
4 Environmental classes
4.0 General
The classes shown in parentheses, e.g. (C3), may be selected for special applications.
These classes shall apply to a non-weatherprotected location.
These classes shall apply to locations:
• which are directly exposed to an open-air climate, including solar radiation, movement of the surrounding air,
precipitation and water jets; splashing water;
• where mould growth, or attacks by animals but excluding termites, may occur;
• with normal levels of contaminants experienced in urban areas with industrial activities scattered over the
whole area and/or with heavy traffic. It also applies to coastal areas;
NOTE 1: At locations in the immediate neighbourhood of industrial sources with chemical emissions either special
precautions should be taken or a special chemical class should be chosen.
ETSI
8 ETSI EN 300 019-1-4 V3.1.1 (2026-05)
• in areas with sand or dust sources, in
...


SLOVENSKI STANDARD
oSIST prEN 300 019-1-4 V3.1.0:2026
01-april-2026
Okoljski inženiring (EE) - Okoljski pogoji in preskusi vplivov okolja na
telekomunikacijsko opremo - 1. del: Klasifikacija okoljskih pogojev - 4. poddel:
Fiksna uporaba na lokacijah, ki niso zaščitene pred vremenskimi vplivi
Environmental Engineering (EE) - Environmental conditions and environmental tests for
telecommunications equipment - Part 1: Classification of environmental conditions - Sub-
part 4: Stationary use at non-weatherprotected locations
Ta slovenski standard je istoveten z: ETSI EN 300 019-1-4 V3.1.0 (2026-02)
ICS:
19.040 Preskušanje v zvezi z Environmental testing
okoljem
33.050.01 Telekomunikacijska Telecommunication terminal
terminalska oprema na equipment in general
splošno
oSIST prEN 300 019-1-4 V3.1.0:2026 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

oSIST prEN 300 019-1-4 V3.1.0:2026

oSIST prEN 300 019-1-4 V3.1.0:2026
Draft ETSI EN 300 019-1-4 V3.1.0 (2026-02)

EUROPEAN STANDARD
Environmental Engineering (EE);
Environmental conditions and environmental tests
for telecommunications equipment;
Part 1: Classification of environmental conditions;
Sub-part 4: Stationary use at non-weatherprotected locations

oSIST prEN 300 019-1-4 V3.1.0:2026
2 Draft ETSI EN 300 019-1-4 V3.1.0 (2026-02)

Reference
REN/EE-017014
Keywords
environment, equipment practice, testing
ETSI
650 Route des Lucioles
F-06921 Sophia Antipolis Cedex - FRANCE

Tel.: +33 4 92 94 42 00  Fax: +33 4 93 65 47 16

Siret N° 348 623 562 00017 - APE 7112B
Association à but non lucratif enregistrée à la
Sous-Préfecture de Grasse (06) N° w061004871

Important notice
The present document can be downloaded from the
ETSI Search & Browse Standards application.
The present document may be made available in electronic versions and/or in print. The content of any electronic and/or
print versions of the present document shall not be modified without the prior written authorization of ETSI. In case of any
existing or perceived difference in contents between such versions and/or in print, the prevailing version of an ETSI
deliverable is the one made publicly available in PDF format on ETSI deliver repository.
Users should be aware that the present document may be revised or have its status changed,
this information is available in the Milestones listing.
If you find errors in the present document, please send your comments to
the relevant service listed under Committee Support Staff.
If you find a security vulnerability in the present document, please report it through our
Coordinated Vulnerability Disclosure (CVD) program.
Notice of disclaimer & limitation of liability
The information provided in the present deliverable is directed solely to professionals who have the appropriate degree of
experience to understand and interpret its content in accordance with generally accepted engineering or
other professional standard and applicable regulations.
No recommendation as to products and services or vendors is made or should be implied.
In no event shall ETSI be held liable for loss of profits or any other incidental or consequential damages.

Any software contained in this deliverable is provided "AS IS" with no warranties, express or implied, including but not
limited to, the warranties of merchantability, fitness for a particular purpose and non-infringement of intellectual property
rights and ETSI shall not be held liable in any event for any damages whatsoever (including, without limitation, damages
for loss of profits, business interruption, loss of information, or any other pecuniary loss) arising out of or related to the use
of or inability to use the software.
Copyright Notification
No part may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and
microfilm except as authorized by written permission of ETSI.
The content of the PDF version shall not be modified without the written authorization of ETSI.
The copyright and the foregoing restriction extend to reproduction in all media.

© ETSI 2026.
All rights reserved.
ETSI
oSIST prEN 300 019-1-4 V3.1.0:2026
3 Draft ETSI EN 300 019-1-4 V3.1.0 (2026-02)
Contents
Intellectual Property Rights . 4
Foreword . 4
Modal verbs terminology . 5
1 Scope . 6
2 References . 6
2.1 Normative references . 6
2.2 Informative references . 6
3 Definition of terms, symbols and abbreviations . 7
3.1 Terms . 7
3.2 Symbols . 7
3.3 Abbreviations . 7
4 Environmental classes . 7
4.0 General . 7
4.1 Class 4.10: sheltered non-weatherprotected locations in tropical, arid, temperate, and cold climatic
classification . 8
4.1.0 Class 4.10 full temperature range . 8
4.1.1 Class 4.10L: sheltered non-weatherprotected locations in cold climatic classification . 8
4.1.2 Class 4.10H: sheltered non-weatherprotected locations in tropical, arid, temperate climatic
classification . 9
4.2 Class 4.11: Open-air non-weatherprotected locations in the tropical climatic . 10
4.3 Class 4.12: Open-air non-weatherprotected locations in the arid and temperate climatic classification . 10
4.4 Class 4.13: Open-air non-weatherprotected locations in the cold and polar climatic classifications . 11
5 Environmental conditions. 12
5.1 Climatic conditions. 12
5.2 Biological conditions . 13
5.3 Chemically active substances . 13
5.4 Mechanically active substances . 15
5.5 Mechanical conditions . 15
5.6 Earthquake conditions . 15
Annex A (informative): Bibliography . 18
Annex B (informative): Change history . 19
History . 20

ETSI
oSIST prEN 300 019-1-4 V3.1.0:2026
4 Draft ETSI EN 300 019-1-4 V3.1.0 (2026-02)
Intellectual Property Rights
Essential patents
IPRs essential or potentially essential to normative deliverables may have been declared to ETSI. The declarations
pertaining to these essential IPRs, if any, are publicly available for ETSI members and non-members, and can be
found in ETSI SR 000 314: "Intellectual Property Rights (IPRs); Essential, or potentially Essential, IPRs notified to
ETSI in respect of ETSI standards", which is available from the ETSI Secretariat. Latest updates are available on the
ETSI IPR online database.
Pursuant to the ETSI Directives including the ETSI IPR Policy, no investigation regarding the essentiality of IPRs,
including IPR searches, has been carried out by ETSI. No guarantee can be given as to the existence of other IPRs not
referenced in ETSI SR 000 314 (or the updates on the ETSI Web server) which are, or may be, or may become,
essential to the present document.
Trademarks
The present document may include trademarks and/or tradenames which are asserted and/or registered by their owners.
ETSI claims no ownership of these except for any which are indicated as being the property of ETSI, and conveys no
right to use or reproduce any trademark and/or tradename. Mention of those trademarks in the present document does
not constitute an endorsement by ETSI of products, services or organizations associated with those trademarks.
DECT™, PLUGTESTS™, UMTS™ and the ETSI logo are trademarks of ETSI registered for the benefit of its
Members. 3GPP™, LTE™ and 5G™ logo are trademarks of ETSI registered for the benefit of its Members and of the
3GPP Organizational Partners. oneM2M™ logo is a trademark of ETSI registered for the benefit of its Members and of ®
the oneM2M Partners. GSM and the GSM logo are trademarks registered and owned by the GSM Association.
Foreword
This draft European Standard (EN) has been produced by ETSI Technical Committee Environmental Engineering (EE),
and is now submitted for the combined Public Enquiry and Vote phase of the ETSI.
The present document is part 1, sub-part 4 of a multi-part deliverable covering the classification of environmental
conditions and environmental tests for telecommunications equipment, as identified below:
Part 1: "Classification of environmental conditions": (see note 1)
Sub-part 0: "Introduction";
Sub-part 1: "Storage";
Sub-part 2: "Transportation";
Sub-part 3: "Stationary use at weatherprotected locations";
Sub-part 4: "Stationary use at non-weatherprotected locations";
Sub-part 5: "Ground vehicle installations";
Sub-part 6: "Ship environments";
Sub-part 7: "Portable and non-stationary use";
Sub-part 8: "Stationary use at underground locations";
Part 2: "Specification of environmental tests" (see note 2).
NOTE 1: Specifies different standardized environmental classes covering climatic and biological conditions,
chemically and mechanically active substances and mechanical conditions during storage, transportation
and in use. Sub-part 1-0 forms a general overview of part 1.
NOTE 2: Specifies the recommended test severities and test methods for the different environmental classes.
ETSI
oSIST prEN 300 019-1-4 V3.1.0:2026
5 Draft ETSI EN 300 019-1-4 V3.1.0 (2026-02)

Proposed national transposition dates
Date of latest announcement of this EN (doa): 3 months after ETSI publication
Date of latest publication of new National Standard
or endorsement of this EN (dop/e): 6 months after doa
Date of withdrawal of any conflicting National Standard (dow): 6 months after doa

Modal verbs terminology
In the present document "shall", "shall not", "should", "should not", "may", "need not", "will", "will not", "can" and
"cannot" are to be interpreted as described in clause 3.2 of the ETSI Drafting Rules (Verbal forms for the expression of
provisions).
"must" and "must not" are NOT allowed in ETSI deliverables except when used in direct citation.
ETSI
oSIST prEN 300 019-1-4 V3.1.0:2026
6 Draft ETSI EN 300 019-1-4 V3.1.0 (2026-02)
1 Scope
The purpose of the present document is to define a class of environmental conditions and their severities to which
equipment may be exposed. Only severe conditions, which may be harmful to the equipment, are included. The
severities specified are those which will have a low probability of being exceeded; generally less than 1 % of the
operating time in a year.
The present document applies to equipment mounted for stationary use including periods of erection work, down time,
maintenance and repair at non-weatherprotected locations defined in clause 5.
2 References
2.1 Normative references
References are either specific (identified by date of publication and/or edition number or version number) or
non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the
referenced document (including any amendments) applies.
Referenced documents which are not found to be publicly available in the expected location might be found in the
ETSI docbox.
NOTE: While any hyperlinks included in this clause were valid at the time of publication, ETSI cannot guarantee
their long-term validity.
The following referenced documents are necessary for the application of the present document.
[1] ETSI EN 300 019-1-3: "Environmental Engineering (EE); Environmental conditions and
environmental tests for telecommunications equipment; Part 1: Classification of environmental
conditions; Sub-part 3: Stationary use at weatherprotected locations".
2.2 Informative references
References are either specific (identified by date of publication and/or edition number or version number) or
non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the
referenced document (including any amendments) applies.
NOTE: While any hyperlinks included in this clause were valid at the time of publication, ETSI cannot guarantee
their long-term validity.
The following referenced documents may be useful in implementing an ETSI deliverable or add to the reader's
understanding, but are not required for conformance to the present document.
[i.1] Void.
[i.2] IEC 60721-3-4:2019: "Classification of environmental conditions - Part 3-4: Classification of
groups of environmental parameters and their severities - Stationary use at non-weatherprotected
locations".
[i.3] Void.
[i.4] ISO 9223:2012: "Corrosion of metals and alloys — Corrosivity of atmospheres — Classification,
determination and estimation".
[i.5] IEC 60721-2-6:2022: "Classification of environmental conditions - Part 2-6: Environmental
conditions appearing in nature - Earthquake vibration and shock".
[i.6] IEC 60068-3-3:2019: "Environmental testing - Part 3-3: Supporting documentation and guidance -
Seismic test methods for equipment".
ETSI
oSIST prEN 300 019-1-4 V3.1.0:2026
7 Draft ETSI EN 300 019-1-4 V3.1.0 (2026-02)
3 Definition of terms, symbols and abbreviations
3.1 Terms
For the purposes of the present document, the following terms apply:
absolute humidity: mass of water vapour in grammes which is associated with one cubic metre of dry air in an
air/water vapour mixture
non-weatherprotected location: location at which the equipment is not protected from direct weather influences
relative humidity: ratio of the partial pressure of the water vapour in moist air at a given temperature, to the partial
pressure of the water vapour in saturated air at the same temperature
sheltered location: location at which a product is covered by a structure to protect it from direct meteorological
conditions, i.e. direct sunlight, heavy rain
stationary use: use of the equipment mounted firmly on the structure, or on mounting devices, or it is permanently
placed at a certain site
NOTE: It is not intended for portable use - but short periods of handling during erection works, down time,
maintenance and repair at the location are included.
3.2 Symbols
Void.
3.3 Abbreviations
For the purposes of the present document, the following abbreviations apply:
RS Response Spectrum
UV UltraViolet
ZPA Zero Period Acceleration
4 Environmental classes
4.0 General
The classes shown in parentheses, e.g. (C3), may be selected for special applications.
These classes shall apply to a non-weatherprotected location.
These classes shall apply to locations:
• which are directly exposed to an open-air climate, including solar radiation, movement of the surrounding air,
precipitation and water jets; splashing water;
• where mould growth, or attacks by animals but excluding termites, may occur;
• with normal levels of contaminants experienced in urban area
...