EN 50180:1997
(Main)Bushings above 1 kV up to 36 kV and from 250 A to 3,15 kA for liquid filled transformers
General Information
- Abstract
This standard is applicable to ceramic and resin insulated bushings for rated voltages above 1 kV up to 36 kV rated currents from 250A up to 3150 A and frequencies from 15 Hz up to 60 Hz for insulating liquid filled transformers. This standard establishes essential dimensions, to ensure interchangeability of bushings and to ensure adequate mounting and interchangeability of mating plug-in separable connectors of equivalent ratings
- Status
- Withdrawn
- Publication Date
- 22-May-1997
- Withdrawal Date
- 30-Nov-2000
- Technical Committee
- CLC/TC 36A - Insulated bushings
- Parallel Committee
- IEC/SC 36A - IEC_SC_36A
- Current Stage
- 9960 - Withdrawal effective - Withdrawal
- Start Date
- 01-Sep-2013
- Completion Date
- 01-Sep-2013
Relations
- Effective Date
- 28-Jan-2023
Get Certified
Connect with accredited certification bodies for this standard

IMQ S.p.A. (Certification)
Italian electrical product certification.

SLG Prüf- und Zertifizierungs GmbH
German testing and certification body.

UL Solutions
Global safety science company with testing, inspection and certification.
Sponsored listings
Frequently Asked Questions
EN 50180:1997 is a standard published by CLC. Its full title is "Bushings above 1 kV up to 36 kV and from 250 A to 3,15 kA for liquid filled transformers". This standard covers: This standard is applicable to ceramic and resin insulated bushings for rated voltages above 1 kV up to 36 kV rated currents from 250A up to 3150 A and frequencies from 15 Hz up to 60 Hz for insulating liquid filled transformers. This standard establishes essential dimensions, to ensure interchangeability of bushings and to ensure adequate mounting and interchangeability of mating plug-in separable connectors of equivalent ratings
This standard is applicable to ceramic and resin insulated bushings for rated voltages above 1 kV up to 36 kV rated currents from 250A up to 3150 A and frequencies from 15 Hz up to 60 Hz for insulating liquid filled transformers. This standard establishes essential dimensions, to ensure interchangeability of bushings and to ensure adequate mounting and interchangeability of mating plug-in separable connectors of equivalent ratings
EN 50180:1997 is classified under the following ICS (International Classification for Standards) categories: 29.180 - Transformers. Reactors. The ICS classification helps identify the subject area and facilitates finding related standards.
EN 50180:1997 has the following relationships with other standards: It is inter standard links to EN 50180:2010. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
EN 50180:1997 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
SLOVENSKI STANDARD
01-november-1997
Bushings above 1 kV up to 36 kV and from 250 A to 3,15 kA for liquid filled
transformers
Bushings above 1 kV up to 36 kV and from 250 A to 3,15 kA for liquid filled transformers
Durchführungen über 1 kV bis 36 kV und von 250 A bis 3,15 kA für flüssigkeitsgefüllte
Transformatoren
Traversées de tensions supérieures à 1 kV jusqu'à 36 kV et de 250 A à 3,15 kA pour
transformateurs à remplissage de liquide
Ta slovenski standard je istoveten z: EN 50180:1997
ICS:
29.080.20 Skoznjiki Bushings
29.180 Transformatorji. Dušilke Transformers. Reactors
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.