General Information

Abstract

Applies to television broadcast receivers, sound broadcast receivers and associated equipment intended for use in the residential, commercial and light industrial environment. Describes the methods of measurement and specified limits applicable to sound and television receivers and to associated equipment with regard to their immunity characteristics to disturbing signals. This standard is also applicable to the immunity of outdoor units of direct to home (DTH) satellite receiving systems for individual reception. Immunity requirements are given in the frequency range 0 Hz to 400 GHz. Radio-frequency tests outside the specified frequency bands or concerning other phenomena than given in this standard are not required. The objective of this standard is to define the immunity test requirements for equipment defined in the scope in relation to continuous and transient, conducted and radiated disturbances including electrostatic discharges. These test requirements represent essential electromagnetic immunity requirements. Test requirements are specified for each port (enclosure or connector) considered. The environments encompassed by this standard are residential, commercial and light-industrial locations, both indoor and outdoor. The following list, although not comprehensive, gives an indication of locations which are included: - residential properties, e.g. houses, apartments, etc.; - retail outlets, e.g. shops, supermarkets, etc.; - business premises, e.g. offices, banks, etc.; - areas of public entertainment, e.g. cinemas, public bars, dance halls, etc.; - outdoor locations, e.g. petrol stations, car parks, amusement and sports centres, etc.; - light-industrial locations e.g. workshops, laboratories, service centres, etc.; - car and boat. Locations which are characterized by their mains power being supplied directly at low voltage from the public mains are considered to be residential, commercial or light industrial.

Status
Withdrawn
Publication Date
20-Feb-2014
Withdrawal Date
20-Aug-2014
Current Stage
9960 - Withdrawal effective - Withdrawal
Start Date
28-Jul-2022
Completion Date
28-Jul-2022

Buy Documents

Addendum

EN 55020:2007/IS3:2014

English language (4 pages)
Preview
Preview
e-Library read for
1 day

Relations

Effective Date
10-Sep-2019
Effective Date
28-Jan-2023

Buy Documents

Addendum

EN 55020:2007/IS3:2014

English language (4 pages)
Preview
Preview
e-Library read for
1 day

Get Certified

Connect with accredited certification bodies for this standard

ANCE

Mexican certification and testing association.

EMA Mexico Verified

Intertek Slovenia

Intertek testing, inspection, and certification services in Slovenia.

UKAS Slovenia Verified

LNE (Laboratoire National de Métrologie et d'Essais)

French national laboratory for metrology and testing.

COFRAC France Verified

Sponsored listings

Frequently Asked Questions

EN 55020:2007/IS3:2014 is a addendum published by CLC. Its full title is "Sound and television broadcast receivers and associated equipment - Immunity characteristics - Limits and methods of measurement". This standard covers: Applies to television broadcast receivers, sound broadcast receivers and associated equipment intended for use in the residential, commercial and light industrial environment. Describes the methods of measurement and specified limits applicable to sound and television receivers and to associated equipment with regard to their immunity characteristics to disturbing signals. This standard is also applicable to the immunity of outdoor units of direct to home (DTH) satellite receiving systems for individual reception. Immunity requirements are given in the frequency range 0 Hz to 400 GHz. Radio-frequency tests outside the specified frequency bands or concerning other phenomena than given in this standard are not required. The objective of this standard is to define the immunity test requirements for equipment defined in the scope in relation to continuous and transient, conducted and radiated disturbances including electrostatic discharges. These test requirements represent essential electromagnetic immunity requirements. Test requirements are specified for each port (enclosure or connector) considered. The environments encompassed by this standard are residential, commercial and light-industrial locations, both indoor and outdoor. The following list, although not comprehensive, gives an indication of locations which are included: - residential properties, e.g. houses, apartments, etc.; - retail outlets, e.g. shops, supermarkets, etc.; - business premises, e.g. offices, banks, etc.; - areas of public entertainment, e.g. cinemas, public bars, dance halls, etc.; - outdoor locations, e.g. petrol stations, car parks, amusement and sports centres, etc.; - light-industrial locations e.g. workshops, laboratories, service centres, etc.; - car and boat. Locations which are characterized by their mains power being supplied directly at low voltage from the public mains are considered to be residential, commercial or light industrial.

Applies to television broadcast receivers, sound broadcast receivers and associated equipment intended for use in the residential, commercial and light industrial environment. Describes the methods of measurement and specified limits applicable to sound and television receivers and to associated equipment with regard to their immunity characteristics to disturbing signals. This standard is also applicable to the immunity of outdoor units of direct to home (DTH) satellite receiving systems for individual reception. Immunity requirements are given in the frequency range 0 Hz to 400 GHz. Radio-frequency tests outside the specified frequency bands or concerning other phenomena than given in this standard are not required. The objective of this standard is to define the immunity test requirements for equipment defined in the scope in relation to continuous and transient, conducted and radiated disturbances including electrostatic discharges. These test requirements represent essential electromagnetic immunity requirements. Test requirements are specified for each port (enclosure or connector) considered. The environments encompassed by this standard are residential, commercial and light-industrial locations, both indoor and outdoor. The following list, although not comprehensive, gives an indication of locations which are included: - residential properties, e.g. houses, apartments, etc.; - retail outlets, e.g. shops, supermarkets, etc.; - business premises, e.g. offices, banks, etc.; - areas of public entertainment, e.g. cinemas, public bars, dance halls, etc.; - outdoor locations, e.g. petrol stations, car parks, amusement and sports centres, etc.; - light-industrial locations e.g. workshops, laboratories, service centres, etc.; - car and boat. Locations which are characterized by their mains power being supplied directly at low voltage from the public mains are considered to be residential, commercial or light industrial.

EN 55020:2007/IS3:2014 is classified under the following ICS (International Classification for Standards) categories: 33.100.20 - Immunity. The ICS classification helps identify the subject area and facilitates finding related standards.

EN 55020:2007/IS3:2014 has the following relationships with other standards: It is inter standard links to EN 55035:2017, EN 55020:2007. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

EN 55020:2007/IS3:2014 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)


SLOVENSKI STANDARD
01-julij-2014
=YRNRYQLLQUDGLRGLIX]LMVNLVSUHMHPQLNLVSULSDGDMRþRRSUHPR.DUDNWHULVWLNH
RGSRUQRVWLSURWLPRWQMDP0HMQHYUHGQRVWLLQPHWRGHPHUMHQMD'RSROQLOR,6
Sound and television broadcast receivers and associated equipment - Immunity
characteristics - Limits and methods of measurement
Ton- und Fernseh-Rundfunkempfänger und verwandte Geräte der
Unterhaltungselektronik -- Störfestigkeitseigenschaften - Grenzwerte und Prüfverfahren
Récepteurs de radiodiffusion et de télévision et équipements associés - Caractéristiques
d'immunité - Limites et méthodes de mesure
Ta slovenski standard je istoveten z: EN 55020:2007/IS3:2014
ICS:
33.100.20 Imunost Immunity
33.160.01 Avdio, video in avdiovizualni Audio, video and audiovisual
sistemi na splošno systems in general
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

INTERPRETATION SHEET
EN 55020/IS3
FEUILLE D'INTERPRETATION
February 2014
INTERPRETATIONSBLATT
ICS 33.100.20
English version
Sound and television broadcast receivers and associated equipment -
Immunity characteristics -
Limits and methods of measurement

Récepteurs de radiodiffusion et de Ton- und Fernseh-Rundfunkempfänger
télévision et équipements associés - und verwandte Geräte der
Caractéristiques d'immunité - Unterhaltungselektronik -
Limites et méthodes de mesure Störfestigkeitseigenschaften -
Grenzwerte und Prüfverfahren
This European Standard was approved by CENELEC on 2013-12-23. CENELEC members are bound to comply
with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard
the status of a national standard without any alteration.

Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the CEN-CENELEC Management Centre or to any CENELEC member.

This European Standard exists in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CENELEC member into its own language and notified
to the CEN-CENELEC Management Centre has the same status as the official versions.

CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus,
the Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany,
Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland,
Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom.

CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung

CEN-CENELEC Management Centre: Avenue Marnix 17, B - 1000 Brussels

© 2014 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 55020:2007/IS3:2014 E

Contents Page
Fo
...