EN 60255-11:2010
(Main)Measuring relays and protection equipment - Part 11: Voltage dips, short interruptions, variations and ripple on auxiliary power supply port
General Information
- Abstract
IEC 60255-11:2008 specifies the general requirements for a.c. and d.c. power supplies, for measuring relays and protection equipment for power system protection, including the control, monitoring and process interface equipment used with those systems. The objective of the tests is to confirm that the equipment under test will operate correctly when energised and subjected to dips, interruptions and alternating components (ripple). The main differences with respect to the previous edition are as follows: addition of voltage dips and interruptions test in a.c.; addition of gradual shut-down/start-up test; addition of reversal of d.c. power supply polarity test.
- Status
- Withdrawn
- Publication Date
- 21-Jan-2010
- Withdrawal Date
- 30-Nov-2012
- Technical Committee
- CLC/TC 95X - Measuring relays and protection equipment
- Drafting Committee
- IEC/TC 95 - IEC_TC_95
- Parallel Committee
- IEC/TC 95 - IEC_TC_95
- Current Stage
- 9960 - Withdrawal effective - Withdrawal
- Start Date
- 28-Jun-2016
- Completion Date
- 28-Jun-2016
Relations
- Effective Date
- 28-Jan-2023
- Effective Date
- 03-Feb-2026
- Effective Date
- 03-Feb-2026
- Effective Date
- 03-Feb-2026
- Effective Date
- 03-Feb-2026
- Effective Date
- 03-Feb-2026
Get Certified
Connect with accredited certification bodies for this standard

IMQ S.p.A. (Certification)
Italian electrical product certification.

SLG Prüf- und Zertifizierungs GmbH
German testing and certification body.

UL Solutions
Global safety science company with testing, inspection and certification.
Sponsored listings
Frequently Asked Questions
EN 60255-11:2010 is a standard published by CLC. Its full title is "Measuring relays and protection equipment - Part 11: Voltage dips, short interruptions, variations and ripple on auxiliary power supply port". This standard covers: IEC 60255-11:2008 specifies the general requirements for a.c. and d.c. power supplies, for measuring relays and protection equipment for power system protection, including the control, monitoring and process interface equipment used with those systems. The objective of the tests is to confirm that the equipment under test will operate correctly when energised and subjected to dips, interruptions and alternating components (ripple). The main differences with respect to the previous edition are as follows: addition of voltage dips and interruptions test in a.c.; addition of gradual shut-down/start-up test; addition of reversal of d.c. power supply polarity test.
IEC 60255-11:2008 specifies the general requirements for a.c. and d.c. power supplies, for measuring relays and protection equipment for power system protection, including the control, monitoring and process interface equipment used with those systems. The objective of the tests is to confirm that the equipment under test will operate correctly when energised and subjected to dips, interruptions and alternating components (ripple). The main differences with respect to the previous edition are as follows: addition of voltage dips and interruptions test in a.c.; addition of gradual shut-down/start-up test; addition of reversal of d.c. power supply polarity test.
EN 60255-11:2010 is classified under the following ICS (International Classification for Standards) categories: 29.120.70 - Relays. The ICS classification helps identify the subject area and facilitates finding related standards.
EN 60255-11:2010 has the following relationships with other standards: It is inter standard links to EN 60255-26:2013, EN 60255-6:1994, EN 61000-4-11:2004, EN 61000-4-17:1999, EN 61000-4-29:2000, EN 61936-1:2010. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
EN 60255-11:2010 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
SLOVENSKI STANDARD
01-december-2010
0HULOQLUHOHMLLQ]DãþLWQDRSUHPDGHO1DSHWRVWQLXSDGLNUDWNHSUHNLQLWYH
VSUHPHPEHQDSHWRVWLLQYDORYLWRVWLQDYKRGX]DSRPRåQRQDSDMDQMH
Measuring relays and protection equipment -- Part 11: Voltage dips, short interruptions,
variations and ripple on auxiliary power supply port
Messrelais und Schutzeinrichtungen - Teil 11: Spannungseinbrüche,
Kurzzeitunterbrechungen, Spannungsschwankungen und Wechselanteil im Anschluss
für die Hilfsstromversorgung
Relais de mesure et dispositifs de protection -- Partie 11: Creux de tension, coupures
brèves, variations et ondulation sur l'accès alimentation auxiliaire
Ta slovenski standard je istoveten z: EN 60255-11:2010
ICS:
29.120.70 Releji Relays
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
EUROPEAN STANDARD
EN 60255-11
NORME EUROPÉENNE
January 2010
EUROPÄISCHE NORM
ICS 29.120.70
English version
Measuring relays and protection equipment -
Part 11: Voltage dips, short interruptions, variations and ripple
on auxiliary power supply port
(IEC 60255-11:2008)
Relais de mesure et dispositifs Messrelais und Schutzeinrichtungen -
de protection - Teil 11: Spannungseinbrüche,
Partie 11: Creux de tension, coupures Kurzzeitunterbrechungen,
brèves, variations et ondulation Spannungsschwankungen
sur l'accès alimentation auxiliaire und Wechselanteil im Anschluss
(CEI 60255-11:2008) für die Hilfsstromversorgung
(IEC 60255-11:2008)
This European Standard was approved by CENELEC on 2009-12-01. CENELEC members are bound to comply
with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard
the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the Central Secretariat or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CENELEC member into its own language and notified
to the Central Secretariat has the same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus,
the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy,
Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia,
Spain, Sweden, Switzerland and the United Kingdom.
CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
Central Secretariat: Avenue Marnix 17, B - 1000 Brussels
© 2010 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 60255-11:2010 E
Foreword
The text of document 95/239/FDIS, future edition 2 of IEC 60255-11, prepared by IEC TC 95, Measuring
relays and protection equipment, was submitted to the IEC-CENELEC parallel vote and was approved by
CENELEC as EN 60255-11 on 2009-12-01.
The following dates were fixed:
– latest date by which the EN has to be implemented
at national level by publication of an identical
national standard or by endorsement (dop) 2010-09-01
– latest date by which the national standards conflicting
with the EN have to be withdrawn (dow) 2012-12-01
Annex ZA has been added by CENELEC.
__________
Endorsement notice
The text of the International Standard IEC 60255-11:2008 was approved by CENELEC as a European
Standard without any modification.
In the official version, for Bibliography, the following note has to be added for the standard indicated:
IEC 61000-6-2 NOTE Harmonized as EN 61000-6-2.
__________
- 3 - EN 60255-11:2010
Annex ZA
(normative)
Normative references to international publications
with their corresponding European publications
The following referenced documents are indispensable for the application of this document. For dated
references, only the edition cited applies. For undated references, the latest edition of the referenced
document (including any amendments) applies.
NOTE When an international publication has been modified by common modifications, indicated by (mod), the relevant EN/HD
applies.
Publication Year Title EN/HD Year
IEC 60255-6 - Electrical relays - EN 60255-6 -
Part 6: Measuring relays and protection
equipment
IEC 61000-4-11 - Electromagnetic compatibility (EMC) - EN 61000-4-11 -
Part 4-11: Testing and measurement
techniques - Voltage dips, short interruptions
and voltage variations immunity tests
IEC 61000-4-17 - Electromagnetic compatibility (EMC) - EN 61000-4-17 -
Part 4-17: Testing and measurement
techniques - Ripple on d.c. input power port
immunity test
IEC 61000-4-29 - Electromagnetic compatibility (EMC) - EN 61000-4-29 -
Part 4-29: Testing and measurement
techniques - Voltage dips, short interruptions
and voltage variations on d.c. input power port
immunity tests
IEC 60255-11
Edition 2.0 2008-10
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
Measuring relays and protection equipment –
Part 11: Voltage dips, short interruptions, variations and ripple on auxiliary
power supply port
Relais de mesure et dispositifs de protection –
Partie 11: Creux de tension, coupures brèves, variations et ondulation sur
l’accès alimentation auxiliaire
INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
COMMISSION
ELECTROTECHNIQUE
PRICE CODE
INTERNATIONALE
L
CODE PRIX
ICS 29.120.70 ISBN 978-2-88910-075-0
– 2 – 60255-11 © IEC:2008
CONTENTS
FOREWORD.3
1 Scope and object.5
2 Normative references .5
3 Terms and definitions .6
4 Requirements .6
4.1 Test levels.6
4.2 Test requirements .6
5 Test equipment.8
6 Test set-up .8
6.1 General .8
6.2 Voltage dips .8
6.3 Voltage interruptions .8
6.4 Alternating component in d.c. (ripple) .8
6.5 Gradual shut-down/start-up test .8
6.6 Polarity inversion.9
7 Test procedure .9
8 Criteria for acceptance .9
9 Test report.10
Bibliography.11
Figure 1 – Gradual shut down/start up test.8
Table 1 – Type, levels and duration of tests .7
Table 2 – Criteria for acceptance .9
60255-11 © IEC:2008 – 3 –
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
MEASURING RELAYS AND PROTECTION EQUIPMENT –
Part 11: Voltage dips, short interruptions, variations
and ripple on auxiliary power supply port
FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC provides no marking procedure to indicate its approval and cannot be rendered responsible for any
equipment declared to be in conformity with an IEC Publication.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any p
...