General Information

Abstract

These cables are for installation in indoor Residential Cabling Systems. They are specified up to 100 MHz. Their design is based on the requirements of the EN 50290 2-1. They are specifically designed for cabling in residential environment supporting ICT and BCT applications. (Telephone, Computer and TV services). This specification defines the constructional details as well as the specific performances of the cables. Unless otherwise specified, all cables covered by this standard may be subjected to voltages not more than 300 V a.c. or 450 V d.c. and shall meet the essential requirements of the low voltage directive. Due to current limitation related to the conductor cross sectional area, they are not intended for direct connection to mains electricity supply. The maximum current rating per conductor is less than or equal to 3 A/mm² unless otherwise specified in the relevant detail specification.

Status
Withdrawn
Publication Date
22-Jun-2006
Withdrawal Date
31-Dec-2008
Parallel Committee
IEC/TC 46 - IEC_TC_46
Current Stage
9960 - Withdrawal effective - Withdrawal
Start Date
23-Jan-2015
Completion Date
23-Jan-2015

Buy Documents

Relations

Effective Date
13-May-2010

Buy Documents

Get Certified

Connect with accredited certification bodies for this standard

ANCE

Mexican certification and testing association.

EMA Mexico Verified

Intertek Slovenia

Intertek testing, inspection, and certification services in Slovenia.

UKAS Slovenia Verified

LNE (Laboratoire National de Métrologie et d'Essais)

French national laboratory for metrology and testing.

COFRAC France Verified

Sponsored listings

Frequently Asked Questions

EN 50441-1:2006 is a standard published by CLC. Its full title is "Cables for indoor residential telecommunication installations - Part 1: Unscreened cables - Grade 1". This standard covers: These cables are for installation in indoor Residential Cabling Systems. They are specified up to 100 MHz. Their design is based on the requirements of the EN 50290 2-1. They are specifically designed for cabling in residential environment supporting ICT and BCT applications. (Telephone, Computer and TV services). This specification defines the constructional details as well as the specific performances of the cables. Unless otherwise specified, all cables covered by this standard may be subjected to voltages not more than 300 V a.c. or 450 V d.c. and shall meet the essential requirements of the low voltage directive. Due to current limitation related to the conductor cross sectional area, they are not intended for direct connection to mains electricity supply. The maximum current rating per conductor is less than or equal to 3 A/mm² unless otherwise specified in the relevant detail specification.

These cables are for installation in indoor Residential Cabling Systems. They are specified up to 100 MHz. Their design is based on the requirements of the EN 50290 2-1. They are specifically designed for cabling in residential environment supporting ICT and BCT applications. (Telephone, Computer and TV services). This specification defines the constructional details as well as the specific performances of the cables. Unless otherwise specified, all cables covered by this standard may be subjected to voltages not more than 300 V a.c. or 450 V d.c. and shall meet the essential requirements of the low voltage directive. Due to current limitation related to the conductor cross sectional area, they are not intended for direct connection to mains electricity supply. The maximum current rating per conductor is less than or equal to 3 A/mm² unless otherwise specified in the relevant detail specification.

EN 50441-1:2006 is classified under the following ICS (International Classification for Standards) categories: 33.120.10 - Coaxial cables. Waveguides. The ICS classification helps identify the subject area and facilitates finding related standards.

EN 50441-1:2006 has the following relationships with other standards: It is inter standard links to EN 45510-2-5:2002. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

EN 50441-1:2006 is associated with the following European legislation: EU Directives/Regulations: 2006/95/EC. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.

EN 50441-1:2006 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)


SLOVENSKI SIST EN 50441-1:2006

STANDARD
oct 2006
Kabli za notranjo stanovanjsko telekomunikacijsko montažo – 1. del:
Nezaslonjeni kabli – 1. stopnja
Cables for indoor residential telecommunication installations – Part 1: Unscreened
cables – Grade 1
ICS 33.120.10 Referenčna številka
©  Standard je založil in izdal Slovenski inštitut za standardizacijo. Razmnoževanje ali kopiranje celote ali delov tega dokumenta ni dovoljeno

EUROPEAN STANDARD
EN 50441-1
NORME EUROPÉENNE
June 2006
EUROPÄISCHE NORM
ICS 33.120.10
English version
Cables for indoor residential telecommunication installations
Part 1: Unscreened cables - Grade 1

Câbles pour les installations résidentielles Innenkabel für
de télécommunications en intérieur Telekommunikationseinrichtungen
Partie 1: Câbles non écrantés - im Wohnbereich
Classe 1 Teil 1: Ungeschirmte Innenkabel -
Klasse 1
This European Standard was approved by CENELEC on 2005-12-06. CENELEC members are bound to comply
with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard
the status of a national standard without any alteration.

Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the Central Secretariat or to any CENELEC member.

This European Standard exists in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CENELEC member into its own language and notified
to the Central Secretariat has the same status as the official versions.

CENELEC members are the national electrotechnical committees of Austria, Belgium, Cyprus, the Czech
Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain,
Sweden, Switzerland and the United Kingdom.

CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung

Central Secretariat: rue de Stassart 35, B - 1050 Brussels

© 2006 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 50441-1:2006 E
Foreword
This European Standard was prepared by SC 46XC, Multicore, Multipair and Quad Data
communication cables, of Technical Committee CENELEC TC 46X, Communication cables.
The text of the draft was submitted to the Unique Acceptance Procedure and was approved
by CENELEC as EN 50441-1 on 2005-12-06.
The following dates were fixed:
– latest date by which the EN has to be implemented
at national level by publication of an identical
national standard or by endorsement (dop) 2007-01-01
– latest date by which the national standards conflicting
with the EN have to be withdrawn (dow) 2009-01-01
__________
- 3 - EN 50441-1:2006
Contents
1 Scope . 5
2 Normative references . 5
3 Quality control . 6
4 Cable construction . 7
4.1 Conductors. 7
4.1.1 Conductor construction. 7
4.1.2 Conductor type . 7
4.2 Insulation . 7
4.2.1 Insulation material. 7
4.2.2 Thickness of the insulation. 7
4.2.3 Colour of the insulated conductor . 7
4.3 Cable element . 7
4.4 Screening of the cable element . 7
4.5 Cabling . 7
4.6 Spare pairs . 7
4.7 Colour code. 7
4.8 Sheath. 8
4.8.1 Sheath material. 8
4.8.2 Sheath construction. 8
4.8.3 Thickness of the sheath . 8
4.9 Ripcord. 8
4.10 Overall diameter . 8
4.11 Identification. 8
4.11.1 Sheath marking. 8
4.11.2 Identification thread. 9
4.12 Delivery length. 9
4.12.1 Labelling. 9
4.12.2 End caps . 9
5 Mechanical requirements. 9
5.1 Conductor . 9
5.2 Insulation . 9
5.3 Sheath. 9
5.4 Finished cable . 9
5.4.1 Sheath integrity. 9
5.4.2 Static bending radius. 10
5.4.3 Abrasion resistance of the sheath. 10
5.4.4 Kink test . 10
5.4.5 Cut-through test . 10
5.4.6 Adhesion of the sheath . 10
5.4.7 Installation capability . 10

6 Environmental and climatic requirements . 13
6.1 Insulation . 13
6.2 Sheath. 13
6.3 Fire behaviour . 13
7 Electrical requirements . 13
7.1 Conductor resistance . 13
7.2 Dielectric strength. 13
7.3 Insulation resistance . 13
7.4 High frequency characteristics . 13
7.4.1 Impedance. 13
7.4.2 Return loss . 14
7.4.3 Attenuation . 14
7.4.4 Crosstalk . 15
7.5 Electromagnetic behaviour . 15
7.5.1 Transfer impedance. 15
7.5.2 Coupling attenuation. 15
7.6 Unbalance attenuation . 15
7.7 Environmental and safety aspects . 15

Figure 1 - Test fixture.11
Figure 2 - Installation test system .12

Table 1 - Cable impedance.13
Table 2 - Maximum cable attenuation .14
Table 3 - Minimum NEXT .15

- 5 - EN 50441-1:2006
1 Scope
These cables are for installation in indoor Residential Cabling Systems. They are specified
up to 100 MHz. Their design is based on the requirements of the EN 50290-2-1. They are
specifically designed for cabling in residential environment supporting ICT and BCT
applications. (Telephone, Computer and TV services). This specification defines the
constructional details as well as the specific performances of the cables.
Unless otherwise specified, all cables covered by this standard may be subjected to
voltages not more than 300 V a.c. or 450 V d.c. and shall meet the essential requirements of
the low voltage directive. Due to current limitation related to the conductor cross sectional
area, they are not intended for direct connection to mains electricity supply. The maximum
current rating per conductor is less than or equal to 3 A/mm² unless otherwise specified in
the relevant detail specification.
2 Normative references
The following referenced documents are indispensable for the application of this document.
For dated references, only the edition cited applies. For undated references, the latest
edition of the referenced document (including any amendments) applies.
Publication Title
EN 50265-2-1 Common test methods for cables under fire conditions - Test for
resistance to vertical flame propagation for a single insulated
conductor or cable
Part 2-1: Procedures - 1 kW pre-mixed flame
Common test methods for cables under fire conditions - Test for
EN 50265-2-2
resistance to vertical flame propagation for a single insulated
conductor or cable
Part 2-2: Procedures - Diffusion flame
EN 50289-1-2 Communication cables - Specifications for test methods
Part 1-2:Electrical test methods - DC resistance
EN 50289-1-3 Communication cables - Specifications for test methods
Part 1-3: Electrical test methods - Dielectric strength
EN 50289-1-4 Communication cables - Specifications for test methods
Part 1-4: Electrical test methods - Insulation resistance
EN 50289-1-6
Communication cables - Specifications for test methods
Part 1-6: Electrical test methods - Electromagnetic performance
EN 50289-1-8 Communication cables - Specifications for test methods
Part 1-8: Electrical test methods - Attenuation
EN 50289-1-10 Communication cables - Specifications for test methods
Part 1-10: Electrical test methods - Crosstalk

Communication cables - Specifications for test methods
EN 50289-1-11
Part 1-11: Electrical test methods - Characteristic impedance, input
impedance, return loss
EN 50289-3-7 Communication cables - Specifications for test methods
Part 3-7: Mechanical test methods - Abrasion resistance of the cable
sheath
Communication cables - Specifications for test methods
EN 50289-3-9
Part 3-9: Mechanical test methods - Bending tests
Communication cables - Specifications for test methods
EN 50289-3-11
Part 3-11: Mechanical test methods - Cable cut-through resistance
EN 50289-3-17 Communication cables - Specifications for test methods
Part 3-17: Mechanical test methods - Adhesion of dielectric and sheath
EN 50290-2-1 Communication cables
Part 2-1: Common design rules and construction
EN 50290-2-22 Communication cables
Part 2-22: Common design rules and construction - PVC sheathing
compounds
EN 50290-2-23 Communication cables
Part 2-23: Common design rules and construction - PE insulation
EN 50290-2-27 Communication cables
Part 2-27: Common design rules and construction - Halogen free flame
retardant thermoplastic sheathing compounds
1)
EN 50290-3 Communication cables
Part 3: Quality assessment
EN 60794-1-2 Optical fibre cables
Part 1-2: Generic specification - Basic optical cable test procedures
(IEC 60794-1-2)
EN 60811-1-1 Insulating and sheathing materials of
...