This document gives to the user guidance to determine the loadability of a dry-type distribution transformer, as defined in and covered by HD 538 in the case of load current with harmonic factors exceeding the maximum values allowed.

Status
Withdrawn
Publication Date
05-May-1997
Withdrawal Date
30-Nov-1997
Technical Committee
CLC/TC 14 - Power transformers
Drafting Committee
IEC/TC 14 - IEC_TC_14
Parallel Committee
IEC/TC 14 - IEC_TC_14
Current Stage
9960 - Withdrawal effective - Withdrawal
Start Date
15-Apr-2016
Completion Date
25-Aug-2026

Buy Documents

Standardization document

HD 538.3 S1:1997

English language (4 pages)
Preview
Preview
e-Library read for
1 day

Relations

Effective Date
29-Jan-2023

Buy Documents

Standardization document

HD 538.3 S1:1997

English language (4 pages)
Preview
Preview
e-Library read for
1 day

Get Certified

Connect with accredited certification bodies for this standard

IMQ S.p.A. (Certification)

Italian electrical product certification.

ACCREDIA Italy Verified

SLG Prüf- und Zertifizierungs GmbH

German testing and certification body.

DAKKS Germany Verified

UL Solutions

Global safety science company with testing, inspection and certification.

ANAB United States Verified

Sponsored listings

Frequently Asked Questions

HD 538.3 S1:1997 is a standardization document published by CLC. Its full title is "Three-phase dry-type distribution transformers 50 Hz, from 100 to 2500 kVA, with highest voltage for equipment not exceeding 36 kV - Part 3: Determination of the power rating of a transformer loaded with non- sinusoidal current". This standard covers: This document gives to the user guidance to determine the loadability of a dry-type distribution transformer, as defined in and covered by HD 538 in the case of load current with harmonic factors exceeding the maximum values allowed.

This document gives to the user guidance to determine the loadability of a dry-type distribution transformer, as defined in and covered by HD 538 in the case of load current with harmonic factors exceeding the maximum values allowed.

HD 538.3 S1:1997 is classified under the following ICS (International Classification for Standards) categories: 29.180 - Transformers. Reactors. The ICS classification helps identify the subject area and facilitates finding related standards.

HD 538.3 S1:1997 has the following relationships with other standards: It is inter standard links to EN 50541-2:2013. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

HD 538.3 S1:1997 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)


SLOVENSKI STANDARD
01-oktober-1997
Three-phase dry-type distribution transformers 50 Hz, from 100 to 2500 kVA, with
highest voltage for equipment not exceeding 36 kV - Part 3: Determination of the
power rating of a transformer loaded with non-sinusoidal current
Three-phase dry-type distribution transformers 50 Hz, from 100 to 2500 kVA, with
highest voltage for equipment not exceeding 36 kV -- Part 3: Determination of the power
rating of a transformer loaded with non- sinusoidal current
Drehstrom-Trocken-Verteilungstransformatoren 50 Hz, 100 - 2500 kVA mit höchster
Spannung für Betriebsmittel bis 36 kV -- Teil 3: Bestimmung der Bemessungsleistung
eines Transformators bei nicht sinusförmigen Lastströmen
Transformateurs triphasés de distribution de type sec, 50 Hz, de 100 à 2500 kVA, avec
une tension la plus élevée pour le matéri
...