EN 60317-26:1996
(Main)Specifications for particular types of winding wires - Part 26: Polyamide-imide enamelled round copper wire, class 200
General Information
- Abstract
IEC 60317-26:1990 specifies the requirements of enamelled round copper winding wire of class 200 with a sole coating based on polamide-imide resin. Class 200 is a thermal class that requires a minimum temperature index of 200 and a heat shock temperature of at least 220 °C. The temperature in degrees Celsius corresponding to the temperature index is not necessarily that at which it is recommended that the wire be operated and this will depend on many factors, including the type of equipment involved. The range of nominal conductor diameters covered by this standard is: Grade 1: 0,071 mm up to and including 1,600 mm; Grade 2: 0,071 mm up to and including 0,500 mm. The nominal conductor diameters are specified in clause 4 of IEC 60317-0-1. This second edition of IEC 60317-26 replaces the first edition issued in 1988.
- Status
- Withdrawn
- Publication Date
- 05-Sep-1996
- Withdrawal Date
- 05-Mar-1997
- Technical Committee
- CLC/TC 55 - Winding wires
- Drafting Committee
- IEC/TC 55 - IEC_TC_55
- Parallel Committee
- IEC/TC 55 - IEC_TC_55
- Current Stage
- 9960 - Withdrawal effective - Withdrawal
- Start Date
- 23-Mar-2023
- Completion Date
- 25-Aug-2026
Relations
- Effective Date
- 03-Feb-2026
- Effective Date
- 03-Feb-2026
- Effective Date
- 29-Jan-2023
- Effective Date
- 29-Jan-2023
Get Certified
Connect with accredited certification bodies for this standard

IMQ S.p.A. (Certification)
Italian electrical product certification.

SLG Prüf- und Zertifizierungs GmbH
German testing and certification body.

UL Solutions
Global safety science company with testing, inspection and certification.
Sponsored listings
Frequently Asked Questions
EN 60317-26:1996 is a standard published by CLC. Its full title is "Specifications for particular types of winding wires - Part 26: Polyamide-imide enamelled round copper wire, class 200". This standard covers: IEC 60317-26:1990 specifies the requirements of enamelled round copper winding wire of class 200 with a sole coating based on polamide-imide resin. Class 200 is a thermal class that requires a minimum temperature index of 200 and a heat shock temperature of at least 220 °C. The temperature in degrees Celsius corresponding to the temperature index is not necessarily that at which it is recommended that the wire be operated and this will depend on many factors, including the type of equipment involved. The range of nominal conductor diameters covered by this standard is: Grade 1: 0,071 mm up to and including 1,600 mm; Grade 2: 0,071 mm up to and including 0,500 mm. The nominal conductor diameters are specified in clause 4 of IEC 60317-0-1. This second edition of IEC 60317-26 replaces the first edition issued in 1988.
IEC 60317-26:1990 specifies the requirements of enamelled round copper winding wire of class 200 with a sole coating based on polamide-imide resin. Class 200 is a thermal class that requires a minimum temperature index of 200 and a heat shock temperature of at least 220 °C. The temperature in degrees Celsius corresponding to the temperature index is not necessarily that at which it is recommended that the wire be operated and this will depend on many factors, including the type of equipment involved. The range of nominal conductor diameters covered by this standard is: Grade 1: 0,071 mm up to and including 1,600 mm; Grade 2: 0,071 mm up to and including 0,500 mm. The nominal conductor diameters are specified in clause 4 of IEC 60317-0-1. This second edition of IEC 60317-26 replaces the first edition issued in 1988.
EN 60317-26:1996 is classified under the following ICS (International Classification for Standards) categories: 29.060.10 - Wires. The ICS classification helps identify the subject area and facilitates finding related standards.
EN 60317-26:1996 has the following relationships with other standards: It is inter standard links to EN 61858-1:2014, EN 60317-0-1:1998, EN 60317-26:1996/A1:1998, EN 60317-26:1996/A2:2010. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
EN 60317-26:1996 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
SLOVENSKI STANDARD
01-september-2001
Specifications for particular types of winding wires - Part 26: Polyamide-imide
enamelled round copper wire, class 200
Specifications for particular types of winding wires -- Part 26: Polyamide-imide enamelled
round copper wire, class 200
Technische Lieferbedingungen für bestimmte Typen von Wickeldrähten -- Teil 26:
Runddrähte aus Kupfer, lackisoliert mit Polyamidimid, Klasse 200
Spécifications pour types particuliers de fils de bobinage -- Partie 26: Fil de section
circulaire en cuivre émaillé avec polyamide-imide, classe 200
Ta slovenski standard je istoveten z: EN 60317-26:1996
ICS:
29.060.10 Žice Wires
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
CEI
NORME
INTERNATIONALE IEC
317-26
INTERNATIONAL
Deuxième édition
STANDARD
Second edition
1990-10
Spécifications pour types particuliers
de fils de bobinage
Partie 26:
Fil de section circulaire en cuivre émaillé
avec polyamide-imide, classe 200
Specifications for particular types
of winding wires
Part 26:
Polyamide-imide enamelled round copper wire,
class 200
Numéro de référence
IEC
Reference number
•
CEI/IEC 317-26: 1990
317-26 ©IEC - 3 -
CONTENTS
Page
FOREWORD 5
INTRODUCTION 7
Clause
1 Scope
2 Normative references 9
3 Definitions and general notes on methods of test 9
4 Dimensions
11 5 Electrical resistance
6 Elongation
7 Springiness
8 Flexibility and adherence
9 Heat shock 11
10 Cut-through
11 Resistance to abrasion
12 Resistance to solvents
13 Breakdown voltage
14 Continuity of insulation 13
15 Temperature index
16 Resistance to refrigerants
17 Solderability
18 Heat or solvent bonding 15
19 Dielectric dissipa on factor ti
20 Resistance to transformer oil
21 Loss of mass
22 High temperature failure
30 Packaging
317-26 0 IEC - 5 -
INTERNATIONAL ELECTROTECHNICAL COMMISSION
SPECIFICATIONS FOR PARTICULAR TYPES
OF WINDING WIRES
enamelled round copper wire,
Part 26: Polyamide-imide
class 200
FOREWORD
1) The formal decisions or agreements of the IEC on technical matters, prepared by Technical Committees on
which all the National Committees having a special interest therein are represented, express, as nearly as
possible, an international consensus of opinion on the subjects dealt with.
They have the form of recommendations for international use and they are accepted by the National
2)
Committees in that sense.
3) In order to promote international unification, the IEC expresses the wish that all National Committees
, will
should adopt the text of the IEC recommendation for their national rules in so far as national conditions
permit. Any divergence between the IEC recommendation and the corresponding national rules should, as
far as possible, be clearly indicated in the latter.
This International Standard has been prepared by IEC Technical Committee No. 55:
Winding wires.
This second edition of IEC 317-26 replaces the first edition issued in 1988.
It has been decided to issue IEC 182 and IEC 317 in a new la out. The text of IEC 182
y
All general
has been incorporated into the relevant IEC 317 without technical changes.
requirements for enamelled round copper wires have been removed to IEC 317-0-1 with-
out technical changes unless otherwise stated in the foreword of IEC 317-0-1.
317-26 © IEC – 7
INTRODUCTION
This International Standard is one of a series which deals with insulated wires used for
windings in electrical equipment. The series has three groups describing:
1) methods of test (IEC 851) ;
2)
specifications (IEC 317);
3) packaging (IEC 264).
SIST
...