EN 60255-24:2001
(Main)Electrical relays - Part 24: Common format for transient data exchange (COMTRADE) for power systems
- BACK
- 03-Jul-2001
- 31-Jan-2002
- 29.120.70
- CLC/TC 95X
Electrical relays - Part 24: Common format for transient data exchange (COMTRADE) for power systems
Defines a format for files containing transient waveform and event data collected from power systems or power system models. Applies to files stored on physical media such as digital hard drives and diskettes.
Elektrische Relais - Teil 24: Standardformat für den Austausch von transienten Daten elektrischer Energieversorgungsnetze (COMTRADE)
Relais électriques - Partie 24: Format commun pour l'échange de données transitoires (CONTRADE) dans les réseaux électriques
Etablit un format pour les fichiers contenant des données sur les événements et les formes d'ondes des transitoires obtenus à partir des réseaux électriques ou de leur modélisation. S'applique à des fichiers destinés à être stockés sur des supports physiques, tels que des disques durs ou des disquettes.
Electrical relays - Part 24: Common format for transient data exchange (COMTRADE) for power systems
General Information
This May Also Interest You
1.1 General This part of the IEC 60255 series specifies the requirements for electromagnetic compatibility for measuring relays and protection equipment. It is applicable to measuring relays and protection equipment and combinations of devices to form schemes for power system protection including the control, monitoring, communication and process interface equipment used with those systems. Tests specified in this document are not required for equipment not incorporating electronic circuits, for example electromechanical relays. The requirements specified in this document are applicable to measuring relays and protection equipment in a condition representative of how new equipment is provided by the manufacturer. All tests specified are type tests only. 1.2 Emission This document specifies limits and test methods, for measuring relays and protection equipment in relation to electromagnetic emissions which might cause interference in other equipment. These emission limits represent electromagnetic compatibility requirements and have been selected to ensure that the disturbances generated by measuring relays and protection equipment, operated normally in substations and power plants, do not exceed a specified level which could prevent other equipment from operating as intended. Test requirements are specified for the enclosure, auxiliary power supply ports, input/output ports, signal/control ports and wired network ports. 1.3 Immunity This document specifies the immunity test requirements for measuring relays and protection equipment in relation to continuous and transient, conducted and radiated disturbances, including electrostatic discharges. These test requirements represent the electromagnetic compatibility immunity requirements and have been selected so as to ensure an adequate level of immunity for measuring relays and protection equipment, operated normally in substations and power plants. NOTE 1 Product safety considerations are not covered in this document. NOTE 2 In special cases, situations will arise where the levels of disturbance could exceed the levels specified in this document, for example where a hand-held transmitter or a mobile telephone is used close to measuring relays and protection equipment. In these instances, special precautions and procedures could have to be employed.
- Standard60 pagesEnglish languagesale 10% offe-Library read for×1 day
IEC 60255-27:2023 specifies the product safety requirements for measuring relays and protection equipment having a rated AC voltage up to 1 000 V, or a rated DC voltage up to 1 500 V. This document specifies essential safety requirements to minimize the risk of fire and hazards caused by electric shock or injury to the user and property. This document specifies only product safety requirements; functional performance of the equipment is not covered. This document covers all the ways in which the equipment can be mounted and used in cabinets, racks and panels. This document also applies to auxiliary devices such as shunts, series resistors, transformers, auxiliary control panels, display devices, etc., that are used in conjunction with measuring relays and protection equipment and are tested together.
- Standard103 pagesEnglish languagesale 10% offe-Library read for×1 day
- 17-Apr-2025
- 29.120.70
- 2014/35/EU
- M/511
- CLC/TC 95X
- Corrigendum4 pagesEnglish languagesale 10% offe-Library read for×1 day
- 27-Apr-2023
- 29.120.70
- CLC/TC 95X
IEC 60255-1:2022 specifies common rules and requirements applicable to measuring relays and protection equipment, including any combination of equipment to form a distributed protection scheme for power system protection such as control, monitoring and process interface equipment, to obtain uniformity of requirements and tests. This document covers the main technologies in use today; other emerging technologies present specific EMC and safety issues but the philosophy in this document will be applied. This second edition cancels and replaces the first edition published in 2009. This edition includes the following significant technical changes with respect to the previous edition: a. scope of document clarified; b. merging units and communications as an integral part of the protection added; c. binary output clarification expanded; d. environmental operating conditions added (Annex B); e. test reference conditions added; f. multiple changes to improve understanding across most clauses; g. derating by manufacturer added; h. safety and EMC tests removed from document and referenced only; i. relay setting and type test guidelines modified (Annex A) j. battery monitor port and low power instrument transformers added.
- Standard49 pagesEnglish languagesale 10% offe-Library read for×1 day
- 26-Jan-2023
- 29.120.70
- CLC/TC 95X
IEC 60255-187-1:2021 specifies the minimum requirements for functional and performance evaluation of (longitudinal) differential protection designed for the detection of faults in ac motors, generators and transformers. This document also defines how to document and publish performance test results. This document defines the influencing factors that affect the accuracy under steady state conditions and performance characteristics during dynamic conditions. The test methodologies for verifying performance characteristics and accuracy are also included in this document. This document, together with IEC 60255-187-2 and IEC 60255-187-3, cancels and replaces IEC 60255-13. This document includes the following significant technical changes with respect to IEC 60255-13: a) IEC 60255-13 has been significantly revised to follow the common structure of the functional standards for protection relays (IEC 60255-1xx series). IEC 60255-187-1 has been developed to address the restrained and unrestrained differential protection of motors, generators and transformers. The revisions include detailed description of the functions including the performance specification, testing and documentation requirements.
- Standard208 pagesEnglish languagesale 10% offe-Library read for×1 day
- Standard208 pagesEnglish languagesale 10% offe-Library read for×1 day
- 16-Sep-2021
- 29.120.70
- CLC/TC 95X
IEC 60255-181:2019 specifies the minimum requirements for functional and performance evaluation of frequency protection. This document also defines how to document and publish performance test results. This document covers the functions based on frequency measurement or rate of change of frequency measurements. This document also covers frequency protection where additional blocking elements are used. This document defines the influencing factors that affect the accuracy under steady state conditions and performance characteristics during dynamic conditions. The test methodologies for verifying performance characteristics and accuracy are also included in this document.
- Standard93 pagesEnglish languagesale 10% offe-Library read for×1 day
- 11-Apr-2019
- 02-Apr-2022
- 29.120.70
- CLC/TC 95X
IEC 60255-121:2014 specifies minimum requirements for functional and performance evaluation of distance protection function typically used in, but not limited to, line applications for effectively earthed, three-phase power systems. This standard also defines how to document and publish performance tests. This standard covers distance protection function whose operating characteristic can be defined on an impedance plane and includes specification of the protection function, measurement characteristics, phase selection, directionality, starting and time delay characteristics. The test methodologies for verifying performance characteristics and accuracy are included in this standard. The standard defines the influencing factors that affect the accuracy under steady state conditions and performance characteristics during dynamic conditions. It also includes the instrument transformer requirements for the protection function. The general requirements for measuring relays and protection equipment are defined in IEC 60255-1.
- Standard150 pagesEnglish languagesale 10% offe-Library read for×1 day
- 03-Jul-2014
- 10-Apr-2017
- 29.120.70
- CLC/TC 95X
IEC 60255-27:2013 describes the product safety requirements for measuring relays and protection equipment having a rated a.c. voltage up to 1 000 V with a rated frequency up to 65 Hz, or a rated d.c. voltage up to 1 500 V. Above these limits, IEC 60664-1 is applicable for the determination of clearance, creepage distance and withstand test voltage. This standard details essential safety requirements to minimize the risk of fire and hazards caused by electric shock or injury to the user. This new edition includes the following significant technical changes with respect to the previous edition: - the removal of tables and diagrams which are from other standards and referring instead directly to the source standard; - all aspects of IEC 60255-5 have been covered and this standard will be withdrawn.
- Standard99 pagesEnglish languagesale 10% offe-Library read for×1 day
- 27-Mar-2014
- 18-Nov-2016
- 29.120.70
- 2006/95/EC
- 2014/35/EU
- 2014/53/EU
- CLC/TC 95X
IEC 60255-127:2010 specifies minimum requirements for over/under voltage relays. The standard includes specification of the protection function, measurement characteristics and time delay characteristics.
- Standard27 pagesEnglish languagesale 10% offe-Library read for×1 day
- 09-Jan-2014
- 18-Sep-2016
- 29.120.70
- CLC/TC 95X
This part of the IEC 60255 series is applicable to measuring relays and protection equipment, taking into account combinations of devices to form schemes for power system protection including the control, monitoring, communication and process interface equipment used with those systems. This standard specifies the requirements for electromagnetic compatibility for measuring relays and protection equipment. Tests specified in this standard are not required for equipment not incorporating electronic circuits, for example electromechanical relays. The requirements specified in this standard are applicable to measuring relays and protection equipment in a new condition and all tests specified are type tests only.
- Corrigendum1 pageEnglish languagesale 10% offe-Library read for×1 day
Questions, Comments and Discussion