EN 61029-1:2009
(Main)Safety of transportable motor-operated electric tools - Part 1: General requirements
Safety of transportable motor-operated electric tools - Part 1: General requirements
Deals with general safety requirements of transportable motor-operated electric tools. It applies in conjunction with a part 2 for a particular type of tool. Examples of these tools are circular saws, band saws, planers, thicknessers, radial arm saws, spindle moulders, thicknessers-planers, etc.
Sicherheit transportabler motorbetriebener Elektrowerkzeuge - Teil 1: Allgemeine Anforderungen
Sécurité des machines-outils électriques semi-fixes - Partie 1: Règles générales
Cette partie de la EN 61029 traite les règles générales de sécurité des machines-outils électriques semi-fixes. Elle s'applique en conjonction avec une partie 2 spécifique à chaque type d'outil. Des exemples de ces outils sont les scies circulaires, les scies à ruban, les raboteuses, les dégauchisseuses, les scies radiales, les toupies, les dégauchisseuses-raboteuses, etc.
Varnost premičnih električnih orodij - 1. del: Splošne zahteve (IEC 61029-1:1990, spremenjen)
Ta standard velja za premična električna orodja ali orodja, gnana z magnetom, namenjena za uporabo znotraj in zunaj prostorov, pri čemer imajo vsa naslednje značilnosti: a) ena oseba jih preprosto premika, vključene pa so lahko preproste naprave, ki olajšujejo prevoz, npr. ročaji, kolesa in podobno; b) uporabljajo se v stacionarnem položaju z ali brez pritrditve, npr. naprave za hitro spajanje, vijaki in podobno; c) uporabljajo se pod nadzorom operaterja; d) niso namenjene za uporabo v neprekinjeni proizvodnji ali proizvodni liniji; e) namenjene so za povezavo z električnim napajanjem s prilagodljivim kablom in vtičnico; f) največja ocenjena napetost ne presega 250 V enofaznega izmeničnega ali enosmernega toka ali 440 V trifaznega izmeničnega toka; g) največja ocenjena vhodna moč ne presega 2500 W za enofazni izmenični ali enosmerni tok in 4000 W za trifazni izmenični tok.
General Information
Relations
Standards Content (Sample)
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.VSUHPHQMHQSicherheit transportabler motorbetriebener Elektrowerkzeuge -- Teil 1: Allgemeine AnforderungenSécurité des machines-outils électriques semi-fixes -- Partie 1: Règles généralesSafety of transportable motor-operated electric tools -- Part 1: General requirements25.140.20Electric toolsICS:Ta slovenski standard je istoveten z:EN 61029-1:2009SIST EN 61029-1:2009en,fr,de01-december-2009SIST EN 61029-1:2009SLOVENSKI
STANDARD
EUROPEAN STANDARD EN 61029-1 NORME EUROPÉENNE
EUROPÄISCHE NORM July 2009
CENELEC European Committee for Electrotechnical Standardization Comité Européen de Normalisation Electrotechnique Europäisches Komitee für Elektrotechnische Normung
Central Secretariat: Avenue Marnix 17, B - 1000 Brussels
© 2009 CENELEC -
All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 61029-1:2009 E
ICS 25.140.20 Supersedes EN 61029-1:2000 + A11:2003 + A12:2003
English version
Safety of transportable motor-operated electric tools -
Part 1: General requirements (IEC 61029-1:1990, modified)
Sécurité des machines-outils électriques semi-fixes -
Partie 1: Règles générales (CEI 61029-1:1990, modifiée)
Sicherheit transportabler motorbetriebener Elektrowerkzeuge -
Teil 1: Allgemeine Anforderungen (IEC 61029-1:1990, modifiziert)
This European Standard was approved by CENELEC on 2009-03-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom.
- 2 -
Foreword The text of the International Standard IEC 61029-1:1990 with common modifications prepared by CENELEC TC 61F, Hand-held and transportable motor-operated electric tools, was approved by CENELEC as EN 61029-1 on 1998-09-01. Two amendments to EN 61029-1, that had been submitted to the Unique Acceptance, were approved during 2002 and published as amendments A11:2003 and A12:2003. Two further draft amendments (prAA and prAB), prepared by the Technical Committee CENELEC TC 61F (transformed into CENELEC TC 116, Safety of hand-held motor-operated electric tools), were submitted to the Unique Acceptance Procedure in August 2007 and March 2008. The text of EN 61029-1:2000 together with its amendments A11:2003 and A12:2003 and the text of the draft amendments prAA and prAB were approved by CENELEC as a new edition of EN 61029-1 on 2009-03-01. This European Standard supersedes EN 61029-1:2000 + A11:2003 + A12:2003. The following dates were fixed: – latest date by which the EN has to be implemented
at national level by publication of an identical
national standard or by endorsement
(dop)
2009-12-29 – latest date by which the national standards conflicting
with the EN have to be withdrawn
(dow)
2009-12-29 In this European Standard the common modifications to the International Standard are indicated by a vertical line in the left margin of the text. This European Standard has been prepared under a mandate given to CEN/CENELEC by the European Commission and the European Free Trade Association and supports the essential health and safety requirements of the Machinery Directive 2006/42/EC. Compliance with the relevant clauses of Part 1 together with a relevant Part 2 of this standard provides one means of conforming with the essential health and safety requirements of the Directive concerned. A relevant Part 2 is one in which the type of tool or an accessory which is to be used with such a tool is within the scope of that Part 2. When a relevant Part 2 does not exist, Part 1 can help to establish the requirements for the tool, but will not by itself provide a means of conforming with the relevant essential health and safety requirements of the Machinery Directive. Warning: Other Requirements arising from other EC Directives can be applicable to the products falling within the scope of this standard. CEN has proposed standards for industrial machines, which may extend to transportable machines. Although CEN and CENELEC have, where appropriate, used common solutions to provide uniform levels of protection, persons using this standard should check the scope of both this and CEN standards to ensure that a correct standard is used. Where necessary normative reference is made to these standards in the relevant Part 2. This European Standard follows the overall requirements of EN ISO 12100-1 and EN ISO 12100-2. Subclauses, tables and figures which are prefixed “Z” are additional to those in IEC 61029-1. NOTE In this standard the following print types are used:
- requirements proper; in roman type
- test specifications: in italic type;
- explanatory matter: in smaller roman type.
- 3 - EN 61029-1:2009 Introduction This European Standard is divided into two parts: Part 1: General requirements, comprising clauses of a general character. Part 2: Particular requirements, dealing with particular types of tools. The requirements in a clause in a Part 2 supplement or modify the corresponding clauses in Part 1. Where the text of Part 2 indicates an "addition" to or a "replacement" of the relevant requirement, test specification or explanation of Part 1, these changes are made to the relevant text of Part 1, which then becomes part of the standard. Where no change is necessary, the words "This clause of Part 1 is applicable" are used in Part 2. 1 Scope 1.1 This standard consists of Part 1 and Part 2 and applies to electric motor-operated or magnetically-driven tools, intended for indoor and for outdoor use, which have all the following characteristics: a) easily moved by one person, simple devices to facilitate transportation may be incorporated, e.g. handles, wheels and the like; b) used in a safe stationary position with or without fixing, e.g. fast clamping devices, bolting and the like; c) used under the control of an operator; d) not intended for continuous production or production line use; e) intended to be connected to electric supply by a flexible cord and a plug; f) maximum rated voltage not exceeding 250 V single-phase, a.c. or d.c., or 440 V three-phase, a.c.; g) maximum rated input not exceeding 2500 W, for single-phase a.c. or d.c., and 4000 W for three-phase a.c. These tools are commonly known as "transportable motor-operated electric tools", hereinafter referred to, in the text, as tools. Examples of these tools are: Circular saws, band saws, planers, thicknessers, radial arm saws, spindle moulders, fret saws, jig saws, mitre/chop saws, wood lathes, belt sanders, disc sanders, thicknessers-planers, chain mortisers, multipurpose machines, combing machines, metal lathes, bench grinders, bench drilling machines, pipe threaders, pipe benders, pipe saws, key cutting machines, sharpening machines, sheet metal shears, concrete drills, concrete saws, wood shredders, pipe cleaners. This European Standard applies also to transportable motor operated tools intended to be connected to a water supply such as mains, tank or vat. 1.2 This standard does not apply to - electric motor-operated household and similar electrical appliances according to EN 60335-1; - hand-held electric motor-operated tools according to EN 50144-1 or EN 60745-1; - small low voltage transformer operated bench tools intended for model making; - machines for preparing or processing food; - tools intended to be used in the presence of explosive atmosphere (dust, vapour or gas); - tools intended to be used with cosmetics or pharmaceutical products; - auxiliary equipment such as external cooling and dust extraction/collection systems. SIST EN 61029-1:2009
- 4 -
2 Definitions For the purpose of this European Standard, the following definitions apply. Where the terms "voltage" and "current" are used, they imply the r.m.s. value unless otherwise specified. 2.1 rated voltage voltage (for three-phase supply, the voltage between phases) assigned to the tool by the manufacturer 2.2 rated voltage range voltage range assigned to the tool by the manufacturer, expressed by its lower and upper limits 2.3 working voltage maximum voltage to which the part under consideration can be subjected when the tool is operating at its rated voltage and under normal conditions of use. Normal conditions of use include changes of voltage within the tool imposed by likely occurrences such as the operation of a circuit breaker or the failure of a lamp. When determining the working voltage, the effect of possible transient voltages on the supply mains is ignored 2.4 rated input input in watts at rated voltage or the mean of the rated voltage range assigned to the tool by the manufacturer 2.5 rated current current at rated voltage or at the mean of the rated voltage range assigned to the tool by the manufacturer NOTE If no current is assigned to the tool, the rated current for the purpose of this standard is determined by calculation from the rated input and the rated voltage and/or by measuring the current when the tool is operating at rated voltage under normal load and at normal operating temperature. 2.6 rated frequency frequency assigned to the tool by the manufacturer 2.7 rated frequency range frequency range assigned to the tool by the manufacturer, expressed by its lower and upper limits 2.8 rated no-load speed no-load speed at rated voltage or at the upper limit of the rated voltage range, assigned to the tool by the manufacturer 2.9 detachable flexible cord flexible cord, for supply or other purposes, intended to be connected to the tool by means of a suitable appliance coupler
NOTE Cord sets are covered by EN 60799; appliance couplers for household and similar general purposes by EN 60320-1. SIST EN 61029-1:2009
- 5 - EN 61029-1:2009 2.10 power supply cord flexible cord, for supply purposes, fixed to, or assembled with, the tool according to one of the following methods: - type X attachment: Method of attachment such that the flexible cord can easily be replaced, without the aid of special purpose tools, by a flexible cord not requiring any special preparation; - type M attachment: Method of attachment such that the flexible cable or cord can easily be replaced, without the aid of special purpose tools, by a special cord with, for example, a moulded-on cord or crimped terminations 2.11 basic insulation insulation applied to live parts to provide basic protection against electric shock NOTE Basic insulation does not necessarily include insulation used exclusively for functional purposes. 2.12 supplementary insulation independent insulation applied in addition to the basic insulation, in order to ensure protection against electric shock in the event of a failure of the basic insulation 2.13 double insulation insulation comprising both basic insulation and supplementary insulation 2.14 reinforced insulation single insulation system applied to live parts, which provides a degree of protection against electric shock equivalent to double insulation under the conditions specified in this standard. "Single insulation system" does not imply that the insulation must be one homogeneous piece. It may comprise several layers which cannot be tested singly as supplementary or basic insulation 2.15 class I tool tool in which protection against electric shock does not rely on basic insulation only, but which includes an additional safety precaution in such a way that means are provided for the connection of accessible conductive parts to the protective (earthing) conductor in the fixed wiring of the installation in such a way that accessible conductive parts cannot become live in the event of a failure of the basic insulation.
NOTE Class I tools may have parts with double insulation or reinforced insulation or parts operating at safety extra-low voltage. For tools intended for use with a flexible cord, the provision includes a protective conductor as part of the flexible cord 2.16 class II tool tool in which protection against electric shock does not rely on basic insulation only, but in which additional safety precautions, such as double insulation or reinforced insulation, are provided, there being no provision for protective earthing or reliance upon installation conditions. Such a tool may be of one of the following types: a) a tool having a durable and substantially continuous enclosure of insulating material which envelopes all metal parts, with the exception of small parts, such as nameplates, screws and rivets, which are isolated from live parts by insulation at least equivalent to reinforced insulation; such a tool is called an insulation-encased class II tool; b) a tool having a substantially continuous metal enclosure, in which double insulation is used throughout, except for those parts where reinforced insulation is used, because the application of double insulation is manifestly impracticable; such a tool is called a metal-encased class II tool; c) a tool which is a combination of types a) and b) SIST EN 61029-1:2009
- 6 -
2.17 class III tool tool in which protection against electric shock relies on supply at safety extra-low voltage (SELV) and in which voltages higher than those of SELV are not generated
2.18 extra-low voltage voltage supplied from a source within the tool and, when the tool is operated at its rated voltage, not exceeding 42 V between conductors and between conductors and earth or, for three-phase supply, not exceeding 24 V between conductors and neutral, the extra-low voltage circuit being separated from other circuits by basic insulation only 2.19 safety extra-low voltage (SELV) nominal voltage not exceeding 42 V between conductors and between conductors and earth or, for three-phase supply, not exceeding 24 V between conductors and neutral, the no-load voltage not exceeding 50 V and 29 V respectively. NOTE 1 When SELV is obtained from the supply mains, it must be through a safety isolating transformer or a convertor with separate windings. NOTE 2 The voltage limits specified are based on th
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.