EN 50306-2:2002
(Main)Railway applications - Railway rolling stock cables having special fire performance - Thin wall - Part 2: Single core cables
General Information
- Abstract
EN 50306-2 specifies requirements for, and constructions and dimensions of, single core cables, rated 300 V to earth, of the following type: Unscreened (0,5 mm2 to 2,5 mm2 single core) All cables have stranded tinned copper conductors and thin wall thickness, halogen-free insulation. They are for use in railway rolling stock as fixed wiring, or wiring where limited flexing in operation is encountered. The requirements provide for a continuous operational life at 105 °C, and a maximum temperature for short-circuit conditions of 160 °C based on a duration of 5 seconds. NOTE 1 Where these single core cables are used as components of sheathed cables, the temperature for continuous operational life depends upon the type of sheath system used. Sheath systems for either 90 °C for 105 °C are defined in other parts of EN 50306. Under fire conditions the cables exhibit special performance characteristics in respect of maximum permissible flame propagation (flame spread) and maximum permissible emission of smoke and toxic gases. These requirements are specified to permit the cables to satisfy Hazard Levels 2, 3 or 4 of EN 45545-11). NOTE 2 Requirements for the emission of smoke and gases are not specified for cables used for Hazard Level 1 of EN 45545-1. NOTE 3 EN 45545-1 is still under development and should be consulted. EN 50306-2 should be used in conjunction with EN 50306-1, General requirements.
- Status
- Withdrawn
- Publication Date
- 29-Oct-2002
- Withdrawal Date
- 30-Jun-2008
- Technical Committee
- CLC/TC 20 - Electric cables
- Drafting Committee
- IEC/TC 20 - IEC_TC_20
- Parallel Committee
- IEC/TC 20 - IEC_TC_20
- Current Stage
- 9960 - Withdrawal effective - Withdrawal
- Start Date
- 30-Dec-2022
- Completion Date
- 30-Dec-2022
Relations
- Effective Date
- 07-Jun-2022
- Effective Date
- 03-Feb-2026
Get Certified
Connect with accredited certification bodies for this standard
IRIS Certification (UNIFE)
International Railway Industry Standard certification.

TÜV SÜD Rail GmbH
TÜV SÜD railway certification services.

Bureau Veritas Railway Certification
Railway and transportation certification.
Sponsored listings
Frequently Asked Questions
EN 50306-2:2002 is a standard published by CLC. Its full title is "Railway applications - Railway rolling stock cables having special fire performance - Thin wall - Part 2: Single core cables". This standard covers: EN 50306-2 specifies requirements for, and constructions and dimensions of, single core cables, rated 300 V to earth, of the following type: Unscreened (0,5 mm2 to 2,5 mm2 single core) All cables have stranded tinned copper conductors and thin wall thickness, halogen-free insulation. They are for use in railway rolling stock as fixed wiring, or wiring where limited flexing in operation is encountered. The requirements provide for a continuous operational life at 105 °C, and a maximum temperature for short-circuit conditions of 160 °C based on a duration of 5 seconds. NOTE 1 Where these single core cables are used as components of sheathed cables, the temperature for continuous operational life depends upon the type of sheath system used. Sheath systems for either 90 °C for 105 °C are defined in other parts of EN 50306. Under fire conditions the cables exhibit special performance characteristics in respect of maximum permissible flame propagation (flame spread) and maximum permissible emission of smoke and toxic gases. These requirements are specified to permit the cables to satisfy Hazard Levels 2, 3 or 4 of EN 45545-11). NOTE 2 Requirements for the emission of smoke and gases are not specified for cables used for Hazard Level 1 of EN 45545-1. NOTE 3 EN 45545-1 is still under development and should be consulted. EN 50306-2 should be used in conjunction with EN 50306-1, General requirements.
EN 50306-2 specifies requirements for, and constructions and dimensions of, single core cables, rated 300 V to earth, of the following type: Unscreened (0,5 mm2 to 2,5 mm2 single core) All cables have stranded tinned copper conductors and thin wall thickness, halogen-free insulation. They are for use in railway rolling stock as fixed wiring, or wiring where limited flexing in operation is encountered. The requirements provide for a continuous operational life at 105 °C, and a maximum temperature for short-circuit conditions of 160 °C based on a duration of 5 seconds. NOTE 1 Where these single core cables are used as components of sheathed cables, the temperature for continuous operational life depends upon the type of sheath system used. Sheath systems for either 90 °C for 105 °C are defined in other parts of EN 50306. Under fire conditions the cables exhibit special performance characteristics in respect of maximum permissible flame propagation (flame spread) and maximum permissible emission of smoke and toxic gases. These requirements are specified to permit the cables to satisfy Hazard Levels 2, 3 or 4 of EN 45545-11). NOTE 2 Requirements for the emission of smoke and gases are not specified for cables used for Hazard Level 1 of EN 45545-1. NOTE 3 EN 45545-1 is still under development and should be consulted. EN 50306-2 should be used in conjunction with EN 50306-1, General requirements.
EN 50306-2:2002 is classified under the following ICS (International Classification for Standards) categories: 13.220.40 - Ignitability and burning behaviour of materials and products; 45.060.01 - Railway rolling stock in general. The ICS classification helps identify the subject area and facilitates finding related standards.
EN 50306-2:2002 has the following relationships with other standards: It is inter standard links to EN 50306-2:2020, EN 50343:2024. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
EN 50306-2:2002 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
SLOVENSKI STANDARD
01-februar-2003
Railway applications - Railway rolling stock cables having special fire performance
- Thin wall - Part 2: Single core cables
Railway applications - Railway rolling stock cables having special fire performance - Thin
wall -- Part 2: Single core cables
Bahnanwendungen - Kabel und Leitungen für Schienenfahrzeuge mit verbessertem
Verhalten im Brandfall - Reduzierte Isolierwanddicken -- Teil 2: Einadrige Kabel und
Leitungen
Applications ferroviaires - Câbles pour matériel roulant ferroviaire ayant des
performances particulières de comportement au feu - Isolation mince -- Partie 2: Câbles
monoconducteurs
Ta slovenski standard je istoveten z: EN 50306-2:2002
ICS:
13.220.40 Sposobnost vžiga in Ignitability and burning
obnašanje materialov in behaviour of materials and
proizvodov pri gorenju products
29.060.20 Kabli Cables
45.060.01 Železniška vozila na splošno Railway rolling stock in
general
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
---------
...