EN IEC 60335-1:2023/prAB:2025
(Amendment)Household and similar electrical appliances - Safety - Part 1: General requirements
Household and similar electrical appliances - Safety - Part 1: General requirements
This European Standard deals with the safety of electrical appliances for household environment and commercial purposes, their rated voltage being not more than 250 V for single-phase and 480 V for others
Sicherheit elektrischer Geräte für den Hausgebrauch und ähnliche Zwecke - Teil 1: Allgemeine Anforderungen
Appareils électrodomestiques et analogues - Sécurité - Partie 1: Exigences générales
Gospodinjski in podobni električni aparati - Varnost - 1. del: Splošne zahteve - Dopolnilo AB
General Information
Relations
Standards Content (Sample)
SLOVENSKI STANDARD
01-oktober-2025
Gospodinjski in podobni električni aparati - Varnost - 1. del: Splošne zahteve -
Dopolnilo AB
Household and similar electrical appliances - Safety - Part 1: General requirements
Sicherheit elektrischer Geräte für den Hausgebrauch und ähnliche Zwecke - Teil 1:
Allgemeine Anforderungen
Appareils électrodomestiques et analogues - Sécurité - Partie 1: Exigences générales
Ta slovenski standard je istoveten z: EN IEC 60335-1:2023/prAB:2025
ICS:
13.120 Varnost na domu Domestic safety
97.030 Električni aparati za dom na Domestic electrical
splošno appliances in general
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
EUROPEAN STANDARD DRAFT
EN IEC 60335-1:2023
NORME EUROPÉENNE
EUROPÄISCHE NORM
prAB
August 2025
ICS 13.120; 97.030 -
English Version
Household and similar electrical appliances - Safety - Part 1:
General requirements
Appareils électrodomestiques et analogues - Sécurité - Sicherheit elektrischer Geräte für den Hausgebrauch und
Partie 1: Exigences générales ähnliche Zwecke - Teil 1: Allgemeine Anforderungen
This draft amendment prAB, if approved, will modify the European Standard EN IEC 60335-1:2023; it is submitted to CENELEC members
for enquiry.
Deadline for CENELEC: 2025-11-14.
It has been drawn up by CLC/TC 61.
If this draft becomes an amendment, CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which
stipulate the conditions for giving this amendment the status of a national standard without any alteration.
This draft amendment was established by CENELEC in three official versions (English, French, German).
A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to
the CEN-CENELEC Management Centre has the same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic,
Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the
Netherlands, Norway, Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Türkiye and the United Kingdom.
Recipients of this draft are invited to submit, with their comments, notification of any relevant patent rights of which they are aware and to
provide supporting documentation.
Warning : This document is not a European Standard. It is distributed for review and comments. It is subject to change without notice and
shall not be referred to as a European Standard.
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2025 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members.
Project: 78895 Ref. No. EN IEC 60335-1:2023/prAB:2025 E
Contents Page
1 European foreword . 3
2 1 Modification to Introduction . 5
3 2 Modification to Clause 1, “Scope” . 5
4 3 Modification to Clause 2, “Normative references” . 5
5 4 Modification to Clause 3, “Terms and definitions” . 5
6 5 Modification to Clause 5, “General conditions for the tests”. 6
7 6 Modification to Clause 6, “Classification” . 6
8 7 Modification to Clause 7, “Marking and instructions” . 7
9 8 Modification to Clause 11, “Heating” . 7
10 9 Modification to Clause 19, “Abnormal operation” . 7
11 10 Modification to Clause 20, “Stability and mechanical hazards” . 8
12 11 Modification to Clause 22, “Construction” . 8
13 12 Modification to Clause 24, “Components” . 9
14 13 Modification to Clause 25, “Supply connection and external flexible cords” . 10
15 14 Modification to Clause 32, “Radiation, toxicity and similar hazards” . 10
16 15 Modification to annexes . 11
17 16 Modification to Bibliography . 28
18 European foreword
19 This document (EN IEC 60335-1:2023/prAB:2025) has been prepared by CLC/TC 61 “Safety of household
20 and similar electrical appliances”.
21 The following dates are fixed:
• latest date by which the existence of this (doa) dav + 6 months
document has to be announced at national
level
• latest date by which this document has to be (dop) dav + 12 months
implemented at national level by publication of
an identical national standard or by
endorsement
• latest date by which the national standards (dow) —*
conflicting with this document have to be
withdrawn
22 *Justification for no dow:
23 EN 60335-1:2012 and its amendments remain valid until all the Parts 2 which are used in conjunction with it
24 have been withdrawn. No date of withdrawal (DOW) has been given pending the updating of all Parts 2 to
25 align with this EN IEC 60335-1:2023/prAB:2025. The applicable date of withdrawal is given in each Part 2. It
26 is intended the DOW for this Part 1 will be fixed once all the Parts 2 have been updated.
27 EN IEC 60335-1:2023/prAB:2025 includes the following significant technical changes with respect to
28 EN IEC 60335-1:2023 :
29 — New test requirements for radio function products;
30 — New requirements for mains voltage selector switch;
31 — Removal of modification of test probe B of IEC 61032 in Clause 20.2;
32 — New requirements for resistors and capacitors used for protective impedance;
33 — Added usage of halogen-free cable;
34 — Modification of requirements related to EMF in products with radio function.
35 This document is read in conjunction with EN IEC 60335-1:2023 .
36 The numbering system for European clauses, subclauses, notes, tables, figures and annexes that are
37 additional to those in the IEC standard are prefixed with the letter “Z”.
38 This document has been prepared under a standardization request addressed to CENELEC by the European
39 Commission. The Standing Committee of the EFTA State subsequently approves these requests for its
40 Member States.
41 For the relationship with EU legislation, see informative Annexes ZZA, ZZB and ZZC, which are an integral
42 part of this document.
As impacted by EN IEC 60335-1:2023/A11:2023.
As impacted by EN IEC 60335-1:2023/A11:2023.
43 Secretary Note 1: the Annexes ZZA, ZZB, ZZC are inside this document for the assessment of the HAS
44 consultant. The annexes will be removed before the publication because the AM12 will not be offered for
45 citation in the OJ up to all the Parts 2 have been updated with this version of Part 1. Consequently, lines 50-
46 51 will be removed before the publication
47 Secretary Note 2: The box with Secretary notes will removed from the standard before the publication
48 Secretary Note 3: The NCs are invited to provide which plug(s) is(are) admitted in the country considering the
49 EU designation in Annex ZG
50 Secretary Note 4: After the plenary meeting of Frankfurt, the link of MD has been modified in MR.
51 Secretary Note 5: The requirement in Clause 22.Z2 has been removed because the RF field strength, power
52 density and SAR in connection with human exposure are already covered by the requirements in cl. 32 making
53 reference to EN 62233 and EN IEC 62311 (EN 62479).
54 1 Modification to Introduction
55 Addition:
56 This European Amendment A12 supplements or modifies the corresponding clauses of the standard
57 EN IEC 60335-1:2023+A11:2023 (Part 1).
58 This document contains requirements for appliances with radio function, remote communication and
59 remote operation.
60 NOTE Z101 For the scope of this document, the term radio appliance is used with the same meaning of radio
61 equipment as defined in Directive 2014/53/EU.
62 2 Modification to Clause 1, “Scope”
63 Replacement:
64 Replace the third paragraph (including the two list items) starting with “This standard deals with the reasonably
65 foreseeable…” with the following:
66 “This standard deals with the reasonably foreseeable hazards of intended use presented by appliances that
67 are encountered by all persons and domestic animals when this is not in contradiction with the intended or
68 reasonably foreseeable use of the appliance.”
69 Secretary Note: the above modification has been discussed and approved by LVD Desk officer for answering
70 to RED HAS consultant comment.
71 3 Modification to Clause 2, “Normative references”
72 Delete the reference to IEC TR 60083.
73 4 Modification to Clause 3, “Terms and definitions”
74 3.8.1 Addition:
75 Note Z1 to entry: Disconnection of the appliance can be met not only by removal of the plug from the socket, but also with
76 a switch, that provides a disconnection.
77 3.Z1 Modification:
78 Replace the word “provides” with “uses”.
79 Secretary note: the change has been introduced for answering to RED HAS consultant (comment 4)
80 Addition:
81 3.Z3 RF output power level
82 mean equivalent isotropically radiated power (e.i.r.p.) of the equipment during a transmission burst
83 [SOURCE: ETSI EN 300 328:2019, 4.3.1.2.2, modified – “The RF output power is defined as the” deleted]
84 3.Z4 transmission burst
85 period in time during a transmission during which the transmitter is continuously on
86 [SOURCE: ETSI EN 300 328:2019, Clause 3]
87 3.Z5 hazardous moving parts
88 moving parts of appliance that can cause injury due to impact, abrasion, cutting or severing, shearing, stabbing
89 or puncture, crushing, entanglement and drawing-in or trapping
90 [SOURCE: Guide to application of the Machinery Directive 2006/42/EC, § 212 Moving parts.]
91 Secretary note: the change has been introduced for answering to LVD and RED HAS consultant comments
92 5 Modification to Clause 5, “General conditions for the tests”
93 Addition:
94 If there is doubt, which condition is the most unfavourable; the test is repeated with possible combination of
95 loads and features of appliance to define the most severe condition and results.
96 5.1 Modification:
97 Delete the NOTE.
98 5.2 Modification:
99 In the eight paragraph starting with “The cumulative stress…”, replace in the third sentence the words “relevant
100 electronic circuits” with “electronic circuits under test”.
101 5.3 Addition:
102 The test of 22.Z1 is carried out before the tests of 6.1.
103 5.6 Addition:
104 NOTE Z1 For tests of voltage selector switches, see 19.15.
105 5.8.Z1 Modification:
106 Delete the subclause.
107 Secretary Note: The above requirements have been moved under Clause 22.Z1 in accordance with decision
108 taken during the CLC/TC61 plenary meeting of October 2023 (See comment DK01 under item 8 in document
109 SEC 2826 RM)
110 5.10 Modification:
111 In the paragraph starting with “If batteries intended for use with the appliance”, replace “manufacturer or …
112 provide the following information” with “following information shall be provided”.
113 Secretary Note: The above modification have been introduced after the quality check of CCMC
114 In the paragraph starting with “If cells intended for use…”, replace “the manufacturer or … each type of cell”
115 with “the information for the specified operating region for charging for each type of cell shall be provided”.
116 Secretary Note: The above modification have been introduced after the quality check of CCMC
117 5.16 Modification:
118 Replace the subclause as follows:
119 “For testing electronic circuits, the stabilized power supply shall meet the following characteristics:
120 — voltage stability: ± 3 percent maximum;
121 — frequency stability: ± 2 percent maximum;
122 — total harmonic distortion (THD): maximum 5 %.
123 NOTE 1 Procedure for measuring Laboratory Power Source characteristics is in operational document IECEE OD-
124 5010:2024”
125 Secretary note: The modification above has been introduced to answer the RED HAS 2 comments
126 5.20 Modification:
127 Replace the text of the subclause with “Void”.
128 6 Modification to Clause 6, “Classification”
129 6.2 Addition:
130 Add the following before the compliance criteria:
131 “The minimum degree of protection against harmful ingress of water shall be IPX0.”
132 Secretary note: The modification above has been introduced to answer the LVD HAS 2 comments
133 7 Modification to Clause 7, “Marking and instructions”
134 7.12 Modification:
135 Replace the text starting with “This appliance is not intended for use by persons…” up to “…do not play with
136 the appliance” with the following:
137 “People with disabilities can use this appliance but might need additional precautions to be taken. This
138 appliance may be used by persons (including children) with reduced physical, sensory or mental capabilities,
139 or lack of experience and knowledge, when they have been given supervision or instruction concerning use of
140 the appliance by a person responsible for their safety.
141 Children and domestic animals should be supervised to ensure that they do not play with the appliance.
142 Check that there are no domestic animals inside the compartment/cavity of the appliance or machine before
143 use.”
144 Addition:
145 Add before the last sentence starting with “Compliance is checked …” the following:
146 “The instructions shall include the possible reasonably foreseeable misuse and, whenever relevant, an
147 information against the effects it may have on the safe use of the appliance.
148 The instructions shall include the substance of the following:
149 WARNING: The power supply shall be disconnected from the appliance during user maintenance.
150 The instructions shall include the substance of the following:
151 CAUTION: Read the instructions before using the appliance
152 This wording may be replaced by symbols ISO 7000-0434A:2004-01 and ISO 7000-0790:2004-01 marked
153 adjacent to each other.”
154 Secretary Note: The above requirements are new in the standard and sourced from HAS consultant
155 comments.
156 8 Modification to Clause 11, “Heating”
157 11.2 Replacement:
158 Replace the first three sentences from the addition with the following:
159 “Appliances having a radio function shall be tested in accordance with 11.7 and in the following configuration:
160 — all transmitters and receivers shall be operated in transmission burst, and
161 — all transmitters and receivers shall be activated in configuration that provide the highest RF output power
162 level.”
163 9 Modification to Clause 19, “Abnormal operation”
164 19.1 Modification:
165 Delete the first sentence in the addition.
166 Delete in the second sentence of the addition the words “most unfavourable”.
167 19.15 Replacement:
168 Replace the sentence with the following:
169 “Appliances incorporating a mains voltage selector switch, are tested at all rated voltages with the mains
170 voltage selector switch set in all positions possible in turn. Appliances are operated under the conditions of
171 Clause 11. If the appliance has several modes of operation, the tests are carried out with the appliance
172 operating in each mode.”
173 Secretary Note for HAS consultant: Compliance is checked as specified in 19.13 as descripted in
174 Clause 19.1 (last paragraph.).
175 Secretary note: The modification above has been introduced to answer the RED HAS comments
176 10 Modification to Clause 20, “Stability and mechanical hazards”
177 20.2 Replacement:
178 Format “Hazardous moving parts” and “hazardous moving parts” in bold, respectively.
179 In the third list item of compliance criteria, replace “a test probe that is similar to test probe B … non-circular
180 stop face” with “a test probe B of IEC 61032”.
181 Secretary note: The modification is introduced as answer on DE FO to EN 60335-1. It was discussed with EU
182 Commission and approved during plenary meeting in September 2023 in Brussels
183 11 Modification to Clause 22, “Construction”
184 22.12 Modification:
185 In the first paragraph, in the last sentence starting with “The requirement concerning…”, add at the end
186 “, except those intended to be installed in an area open to the public”.
187 Secretary note: The requirement concerning the choking hazard does not apply to appliances intended for
188 commercial use, except those intended to be installed in an area open to the public.
189 22.42 Replace the subclause with the following:
190 “Protective impedance shall consist of:
191 — at least two separate components; or
192 — a single Class Y1 capacitor complying with IEC 60384-14:2023, including 8.4.1, with a passive
193 flammability category B and 21 days minimum duration for the damp heat, steady-state test.
194 Component impedances shall be unlikely to change significantly during the lifetime of the appliance.
195 When two or more separate components are used for protective impedance:
196 — each capacitor shall comply with the requirements for Class Y capacitors in IEC 60384-14;
197 — each resistor shall comply with the test below.
198 Each capacitor used for protective impedance shall be appropriately rated for the working voltage and
199 environmental conditions of the application where it is used.
200 For protective impedance, if any one of the components is open-circuited or, when two or more separate
201 components are used, if each component in turn is short-circuited, the values specified in 8.1.4 shall not be
202 exceeded.
203 Compliance is checked by inspection, by measurements and, for resistors, by the following tests which are
204 carried out on ten samples of each resistor.
205 The resistance of each sample resistor is measured.
206 Each sample resistor shall then be subjected to the damp heat test according to IEC 60068-2-78, with the
207 following minimum details:
208 — temperature: (40 ± 2) °C;
209 — humidity: (93 ± 3) % relative humidity;
210 — test duration: 21 days.
211 Each sample resistor is then subjected to the impulse voltage test of Clause 14 using the next higher step for
212 rated impulse voltage from Table 15.
213 After the test, the resistance of each sample resistor is measured again, and it shall not have changed by more
214 than 10 %.
215 No failure of each sample resistor is allowed.”
216 ED GR comment: confirmation of the text will be delivered by MT37 of IEC TC61 and CLC/TC61 will copy the
217 same words (if the 2CDV will be voted positive) otherwise the CMs will introduce the text above.
218 In accordance with the above decision take during the CLC/TC61 plenary meeting, ED GR incorporate in the
219 clause the text of Annex A in IEC document 61/7363/RVC.
220 Secretary note: The modification above has been introduced to answer the LVD HAS 1 comments
221 22.44 Modification:
222 In the third paragraph starting with “If the appliance is child-appealing”, delete “and” and the two list items.
223 Secretary note: the sentence becomes:
224 If the appliance is child-appealing the following conditions shall be met:
225 Format “Hazardous moving parts” in bold.
226 In the list item starting with “Hazardous moving…”, add “including those performing the working function”
227 before “shall not be accessible…”.
228 Secretary note: the list item becomes:
229 Hazardous moving parts including those performing the working function shall not be accessible by means
230 of test probe 19 of EN 61032:1998 under the conditions specified for test probe 18 in 20.2.
231 Delete the sentence “The existence of a toy shaped.” and NOTE Z1.
232 Add the following subclause:
233 “22.Z1 Appliances that are intended to be connected to the supply mains shall cover:
234 — 230 Vac for single-phase appliances;
235 — 400 Vac for multi-phase appliances.
236 NOTE Z1 Requirements as specified in EN 50160:2022, 4.1.
237 NOTE Z2 Appliances not intended to be connected to the public supply mains can differ from the requirements given in
238 EN 50160:2022. Examples are appliances used on board ships or aircraft.
239 Compliance is checked by inspection.
240 Secretary Note: The above requirements has been moved from Clause 5 to Clause 22.Z1 in accordance with
241 decision taken during the CLC/TC61 plenary meeting of October 2023 (See comment DK01 under item 8 in
242 document SEC 2826 RM)
243 12 Modification to Clause 24, “Components”
244 24.1 Modification:
245 In the penultimate paragraph of the compliance criteria, delete “such as those detailed in IEC TR 60083”.
246 Delete NOTE Z2.
247 Secretary Note: The above modification have been introduced after the quality check of CCMC
248 24.4 Replacement:
As impacted by EN 50160:2022/A1:2025.
249 Replace “IEC TR 60083 or” with “national socket outlet and plug standards”.
250 Addition:
251 NOTE Z1 Information details of the plugs and national plug standards are given in informative Annex ZG.
252 Secretary Note: The above modification have been introduced after the quality check of CCMC
253 13 Modification to Clause 25, “Supply connection and external flexible cords”
254 25.1 Modification:
255 Delete the addition.
256 Addition:
257 NOTE Z1 Information details of the plugs and national plug standards are given in informative Annex ZG.
258 Secretary Note: The above modification have been introduced after the quality check of CCMC
259 25.7 Addition:
260 Add the following as a new list item:
261 “
262 — Cross-linked halogen-free compound sheathed
263 Their properties shall be at least those of cross-linked halogen-free compound sheathed cord (code
264 designation H07ZZ-F).”
265 Secretary Note: The above modification have been introduced after the plenary meeting of Frankfurt 2024.
266 See green document in RM SEC2894 item7
267 25.25 Replacement:
268 Replace the requirement with the following:
269 “Dimensions of the plugs, pins for insertion into socket outlets and engagement faces are to be in accordance
270 with the dimensions given in the national plug standard relevant for the countries in which the appliance is to
271 be sold.
272 NOTE Z1 Information details of the plugs and national plug standards are given in informative Annex ZG.”
273 Secretary Note: The above modification have been introduced after the quality check of CCMC
274 14 Modification to Clause 32, “Radiation, toxicity and similar hazards”
275 32.1 Modification:
276 In the first list item, replace “products without radio function” with “all products and”.
277 In the second list item, after “EN IEC 62311:2020” add “or EN 62479:2010”.
278 Note Z1 shall be changed to normative text.
279 Secretary Note: The above modification coming from WG11 for reflecting the flow chart in the Annex ZH.
280 With this modification the requirement become:
281 However, appliances are tested in accordance with the following standards to ensure compliance regarding
282 electromagnetic fields:
283 — EN 62233:2008 for all products and
284 — EN IEC 62311:2020 or EN 62479:2010 for products with radio function.
285 Guidelines are given in informative Annex ZH
286 15 Modification to annexes
287 Annex ZA
288 (normative)
289 Normative references to international publications with their
290 corresponding European publications
291 Delete the row for IEC/TR 60083.
292 Replace the following row as follows:
IEC 62821 series Electric cables - Halogen-free, low smoke,
thermoplastic insulated and sheathed cables
of rated voltages up to and including
450/750 V
294 Secretary Note: The above change has been request by RED HAS comment 11. At IEC level, the cables are
295 covered by IEC 60227, IEC 62821 and IEC 60245 but at European level all of them are covered by EN 50525
296 series.
297 Change the dates of the references as follows:
EN 50160 2022
Voltage characteristics of electricity supplied
by public electricity networks
+ A1 2025
IEC 60127 series Miniature fuses EN IEC 60127-1 2024
EN 60127-2 2014
+ A1 2023
EN IEC 60127-6 2024
EN IEC 60127-8 2018
+ A1 2024
IEC 60799 - Electrical accessories - Cord sets and EN IEC 60799 2021
interconnection cord sets
+ A1 2023
IEC 60112 2003 Method for the determination of the proof EN IEC 60112 2020
2009 and the comparative tracking indices of
+ A1
solid insulating materials
IEC 60384-14 2013 Fixed capacitors for use in electronic EN IEC 60384-14 2023
equipment - Part 14: Sectional specification
+ A1 2016
- Fixed capacitors for electromagnetic
+ AC 2024
interference suppression and connection to
the supply mains
IEC 60445 2017 Basic and safety principles for man- EN IEC 60445 2021
machine interface, marking and
identification - Identification of equipment
terminals, conductor terminations and
conductors
IEC 60598-1 2014 Luminaires - Part 1: General requirements EN IEC 60598-1 2024
and tests
+ A1 2017
+ A11 2024
EN 50525 series applies instead of IEC 62821 series (see details above).
IEC 60664-1 2007 Insulation coordination for equipment within EN IEC 60664-1 2020
low-voltage systems - Part 1: Principles,
+ AC 2020
requirements and tests
IEC 60691 - Thermal-links - Requirements and EN IEC 60691 2023
application guide
+ A1 2024
IEC 60695-2-11 2014 Fire hazard testing - Part 2–11: EN IEC 60695-2-11 2021
Glowing/hot-wire based test methods -
Glow-wire flammability test method for end
products (GWEPT)
IEC 60730-1 2013 Automatic electrical controls - Part 1: EN IEC 60730-1 2024
General requirements
+ A1 2015 + A11 2024
IEC 60799 - Electrical accessories – Cord sets and EN IEC 60799 2021
interconnection cord sets
+ A1 2023
IEC 61000-4-2 - Electromagnetic compatibility (EMC) - Part EN IEC 61000-4-2 2025
4–2: Testing and measurement techniques
- Electrostatic discharge immunity test
Electromagnetic compatibility (EMC) - Part
...








Questions, Comments and Discussion