General Information

Abstract

This European Standard specifies ranges, construction, performances, output characteristics and testing of rotary displacement gas meters (hereinafter referred to as RD meters or simply meters) for gas volume measurement.
This European Standard applies to rotary displacement gas meters used to measure the volume of fuel gases of the 1st, 2nd and 3rd gas families, the composition of which is specified in EN 437, at a maximum working pressure up to and including16 bar over a gas temperature range of at least -10 °C to +40 °C.
Unless otherwise specified in this standard, all pressures used are gauge pressures.

Status
Withdrawn
Publication Date
05-Feb-2002
Withdrawal Date
16-Sep-2026
Technical Committee
CEN/TC 237 - Gas meters
Current Stage
9960 - Withdrawal effective - Withdrawal
Start Date
11-Mar-2015
Completion Date
17-Sep-2026
Directive
Not Harmonized2004/22/EC - Measuring instruments
OJ Ref: C, C 162 OJ Date: 14-Jul-2007

Buy Documents

Relations

Effective Date
02-Apr-2014
Effective Date
25-Aug-2026
Effective Date
25-Aug-2026
Effective Date
25-Aug-2026
Effective Date
25-Aug-2026
Effective Date
09-Feb-2026
Effective Date
09-Feb-2026
Effective Date
09-Feb-2026
Effective Date
09-Feb-2026
Effective Date
09-Feb-2026
Effective Date
28-Jan-2026
Effective Date
28-Jan-2026
Effective Date
28-Jan-2026
Effective Date
28-Jan-2026
Effective Date
28-Jan-2026

Buy Documents

Get Certified

Connect with accredited certification bodies for this standard

DIBt (Deutsches Institut für Bautechnik)

German Institute for Building Technology.

DAKKS Germany Verified

DIN CERTCO

DIN Group product certification.

DAKKS Germany Verified

Aboma Certification B.V.

Specialized in construction, metal, and transport sectors.

RVA Netherlands Verified

Sponsored listings

Frequently Asked Questions

EN 12480:2002 is a standard published by the European Committee for Standardization (CEN). Its full title is "Gas meters - Rotary displacement gas meters". This standard covers: This European Standard specifies ranges, construction, performances, output characteristics and testing of rotary displacement gas meters (hereinafter referred to as RD meters or simply meters) for gas volume measurement. This European Standard applies to rotary displacement gas meters used to measure the volume of fuel gases of the 1st, 2nd and 3rd gas families, the composition of which is specified in EN 437, at a maximum working pressure up to and including16 bar over a gas temperature range of at least -10 °C to +40 °C. Unless otherwise specified in this standard, all pressures used are gauge pressures.

This European Standard specifies ranges, construction, performances, output characteristics and testing of rotary displacement gas meters (hereinafter referred to as RD meters or simply meters) for gas volume measurement. This European Standard applies to rotary displacement gas meters used to measure the volume of fuel gases of the 1st, 2nd and 3rd gas families, the composition of which is specified in EN 437, at a maximum working pressure up to and including16 bar over a gas temperature range of at least -10 °C to +40 °C. Unless otherwise specified in this standard, all pressures used are gauge pressures.

EN 12480:2002 is classified under the following ICS (International Classification for Standards) categories: 91.140.40 - Gas supply systems. The ICS classification helps identify the subject area and facilitates finding related standards.

EN 12480:2002 has the following relationships with other standards: It is inter standard links to EN 12480:2015, ISO 2768-1:1989, ISO 228-1:2000, ISO 7005-2:1988, ISO 7005-1:1992, EN IEC 60079-0:2018, EN 60529:1991, EN 60947-5-6:2000, ISO 834-1:1999, EN IEC 60079-11:2024, EN 437:2021, EN 12631:1999, EN 10204:2004, EN ISO 14146:2024, CEN ISO/TS 18090-1:2019. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

EN 12480:2002 is associated with the following European legislation: EU Directives/Regulations: 2004/22/EC; Standardization Mandates: M/374. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.

EN 12480:2002 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)


2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Gas meters - Rotary displacement gas metersPlinomeri - Plinomeri z rotacijskimi batiCompteurs de gaz - Compteurs de gaz a déplacement rotatifsGaszähler - DrehkolbengaszählerTa slovenski standard je istoveten z:EN 12480:2002SIST EN 12480:2004en91.140.40Sistemi za oskrbo s plinomGas supply systemsICS:SLOVENSKI
STANDARDSIST EN 12480:200401-februar-2004

EUROPEAN STANDARDNORME EUROPÉENNEEUROPÄISCHE NORMEN 12480February 2002ICS 91.140.40English versionGas meters - Rotary displacement gas metersCompteurs de gaz - Compteurs de gaz à déplacementrotatifsGaszähler - DrehkolbengaszählerThis European Standard was approved by CEN on 16 November 2001.CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this EuropeanStandard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such nationalstandards may be obtained on application to the Management Centre or to any CEN member.This European Standard exists in three official versions (English, French, German). A version in any other language made by translationunder the responsibility of a CEN member into its own language and notified to the Management Centre has the same status as the officialversions.CEN members are the national standards bodies of Austria, Belgium, Czech Republic, Denmark, Finland, France, Germany, Greece,Iceland, Ireland, Italy, Luxembourg, Malta, Netherlands, Norway, Portugal, Spain, Sweden, Switzerland and United Kingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMITÉ EUROPÉEN DE NORMALISATIONEUROPÄISCHES KOMITEE FÜR NORMUNGManagement Centre: rue de Stassart, 36
B-1050 Brussels© 2002 CENAll rights of exploitation in any form and by any means reservedworldwide for CEN national Members.Ref. No. EN 12480:2002 E

flow.329.3Pressure tappings.329.4Durability and legibility of marking.329.4.1Requirements.329.4.2Indelibility test.32Annex A (normative)
Pattern approval tests.33Annex B (normative)
Individual meter testing.35Annex C (normative)
Resistance to high temperature (optional).36C.1Requirements.36C.2Test.36C.2.1Apparatus.36C.2.2Test conditions.36C.2.3Test procedure.37C.3Marking.38Bibliography.39

100) mbar and temperature of (20
5) C 100
= cciVVVE
(m3/h)161,60,80,50,30,250,160,100,080,065252,51,30,80,50,40,250,160,130,1040421,30,80,650,40,250,20,16656,53,221,310,650,40,30,251001053,221,610,650,50,416016853,22,51,610,80,6525025138542,51,61,3140040201386,542,52,01,665065322013106,543,22,51 00010050322016106,5541 60016080503225161086,52 500250130805040251613104 0004002001308065402520166 500650320200130100654032254.3 Pressure rangeThe pressure range shall be from the atmospheric pressure to the maximum allowable working pressure stated bymanufacturer and shall be marked on the meter.

Q < QtQt
Q
Qmax 2 % 1 %Transitional flowrate values, Qt, are given in Table 5:

1: 30
1: 50> 1: 500,20 Qmax0,15 Qmax0,10 Qmax0,05 QmaxEach meter shall be adjusted so that the "weighted mean error" (WME) is as close to zero as the adjustment andthe maximum permissible errors allow.The WME shall have a value between -0,4 % and +0,4 %.The WME is calculated as follows:Where:Qi /Qmax is a weighting factor;Ei is the error of indication at the flow rate QI given as a percentage.When Qi = Qmax a weighting factor of 0,4 instead of 1 shall be used.5.1.2 TestThe test is carried out using air (density 1,2 kgm-³), or gas specified in the scope, at normal ambient conditions.The meter is tested at the following flow rates ( 10 %):a)type test:1)for meters with flowrate range between 1:10 to 1:30:Qmin; 0,05 Qmax; 0,1Qmax (when these values are larger than Qmin); 0,25 Qmax; 0,4 Qmax;0,7Qmax; Qmax.2)for meters with a flowrate range
1:50: Qmin; 0,05 Qmax; 0,15 Qmax; 0,25 Qmax; 0,40 Qmax; 0,70 Qmax; Qmax.b)individual factory testing for error of indication (every meter shall be tested): Qmin; 0,25 Qmax; Qmax.) /(
) /(
= maxiimaxiQQEQQWME
5) °C (nominal) and the procedures and results shallbe recorded and available. For each nominal diameter, one sample meter shall be tested.6.3.1.3 Individual factory
testingThe test equipment shall not subject the meter to external applied stress which may significantly affect the result ofthis test.
...