General Information

Abstract

This European Standard specifies the additional requirements for underground or partly underground systems top lifted and bottom emptied, used for collection of solid non-hazardous wastes with a capacity up to 5 000 l.

Status
Withdrawn
Publication Date
01-Oct-2013
Withdrawal Date
16-Sep-2026
Technical Committee
CEN/TC 183 - Waste management
Current Stage
9960 - Withdrawal effective - Withdrawal
Start Date
10-Jul-2019
Completion Date
17-Sep-2026

Buy Documents

Standard

EN 13071-2:2008+A1:2014

English language (13 pages)
Preview
Preview
e-Library read for
1 day

Relations

Effective Date
19-Jan-2023
Effective Date
18-Jan-2023
Effective Date
17-Jul-2019
Effective Date
09-Feb-2026
Effective Date
28-Jan-2026
Effective Date
28-Jan-2026
Effective Date
28-Jan-2026

Buy Documents

Standard

EN 13071-2:2008+A1:2014

English language (13 pages)
Preview
Preview
e-Library read for
1 day

Get Certified

Connect with accredited certification bodies for this standard

CIS Institut d.o.o.

Personal Protective Equipment (PPE) certification body. Notified Body NB-2890 for EU Regulation 2016/425 PPE.

SA Slovenia Verified

Kiwa BDA Testing

Building and construction product certification.

RVA Netherlands Verified

Kmetijski inštitut Slovenije

Agricultural Institute of Slovenia. Soil testing, plant health, agricultural product analysis.

SA Slovenia Verified

Sponsored listings

Frequently Asked Questions

EN 13071-2:2008+A1:2013 is a standard published by the European Committee for Standardization (CEN). Its full title is "Stationary waste containers up to 5 000 l, top lifted and bottom emptied - Part 2: Additional requirements for underground or partly underground systems". This standard covers: This European Standard specifies the additional requirements for underground or partly underground systems top lifted and bottom emptied, used for collection of solid non-hazardous wastes with a capacity up to 5 000 l.

This European Standard specifies the additional requirements for underground or partly underground systems top lifted and bottom emptied, used for collection of solid non-hazardous wastes with a capacity up to 5 000 l.

EN 13071-2:2008+A1:2013 is classified under the following ICS (International Classification for Standards) categories: 13.030.40 - Installations and equipment for waste disposal and treatment. The ICS classification helps identify the subject area and facilitates finding related standards.

EN 13071-2:2008+A1:2013 has the following relationships with other standards: It is inter standard links to EN 13071-2:2008, EN 13071-2:2008/AC:2010, EN 13071-2:2019, ISO 2081:2008, EN 10346:2015, EN ISO 1461:2022, EN 13071-1:2008. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

EN 13071-2:2008+A1:2013 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)


2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.LVWHPHStationäre Abfallsammelbehälter bis 5 000 l, mit Behälteraufnahme an der Oberseite und Bodenentleerung - Teil 2: Zusätzliche Anforderungen für unterirdische oder teilweise unterirdische SystemeConteneurs fixes à déchets de capacité inférieure ou égale à 5 000 l, levés par le haut et vidés par le bas - Partie 2: Exigences complémentaires relatives aux systèmes enterrés ou semi-enterrésStationary waste containers up to 5 000 l, top lifted and bottom emptied - Part 2: Additional requirements for underground or partly underground systems13.030.40Naprave in oprema za odstranjevanje in obdelavo odpadkovInstallations and equipment for waste disposal and treatmentICS:Ta slovenski standard je istoveten z:EN 13071-2:2008+A1:2013SIST EN 13071-2:2008+A1:2014en,fr,de01-januar-2014SIST EN 13071-2:2008+A1:2014SLOVENSKI
STANDARDSIST EN 13071-2:20081DGRPHãþD

EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM
EN 13071-2:2008+A1
October 2013 ICS 13.030.40 Supersedes EN 13071-2:2008
English Version
Stationary waste containers up to 5 000 l, top lifted and bottom emptied - Part 2: Additional requirements for underground or partly underground systems
Conteneurs fixes à déchets de capacité inférieure ou égale à 5 000 l, levés par le haut et vidés par le bas - Partie 2: Exigences complémentaires relatives aux systèmes enterrés ou semi-enterrés
Stationäre Abfallsammelbehälter bis 5 000 l, mit Behälteraufnahme an der Oberseite und Bodenentleerung - Teil 2: Zusätzliche Anforderungen für unterirdische oder teilweise unterirdische Systeme This European Standard was approved by CEN on 18 April 2008 and includes Corrigendum 1 issued by CEN on 24 March 2010 and Amendment 1 approved by CEN on 19 August 2013.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION
EUROPÄISCHES KOMITEE FÜR NORMUNG
CEN-CENELEC Management Centre:
Avenue Marnix 17,
B-1000 Brussels © 2013 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 13071-2:2008+A1:2013: E SIST EN 13071-2:2008+A1:2014

A–deviations . 13
Figures Figure 1 — Underground and partly underground system . 5 Figure 2 — Example of resistance of emergent part to exterior impacts . 10 Tables Table 1 — Sequence of the tests . 12
1 Scope This European Standard specifies the additional requirements for underground or partly underground systems top lifted and bottom emptied, used for collection of solid non-hazardous wastes with a capacity up to 5 000 l. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 10327, Continuously hot-dip coated strip and sheet of low carbon steels for cold forming - Technical delivery conditions EN 13071-1:2008, Stationary waste containers up to 5 000 l, top lifted and bottom emptied – Part 1: General requirements EN ISO 1461, Hot dip galvanized coatings on fabricated iron and steel articles – Specifications and test methods (ISO 1461:1999) ISO 2081, Metallic coatings – Electroplated coatings of zinc on iron or steel SIST EN 13071-2:2008+A1:2014

3 Terms and definitions For the purposes of this document, the terms and definitions given in EN 13071-1:2008 and the following apply. 3.1 underground or partly underground system system whose emptying device is located below surrounding ground level at any point
a) partly underground system b) underground system Key C
container EP
emergent part H
housing L
liner LC
lifting connection PP
pedestrian platform R
roof
Figure 1 — Underground and partly underground system
3.2 container
mobile part of underground or partly underground system, designated to collect/receive the waste 3.3 liner
equipment installed fully or partly in the ground, whose function is to receive the container SIST EN 13071-2:2008+A1:2014

part of the container that is fixed to the pedestrian platform, above ground level, that is used to fill the container 3.5 pedestrian platform
part of the system to
...