General Information

Abstract

In addition to the requirements given in EN 15182-1, this part of this European Standard applies to hand-held branchpipes with smooth bore jet and/or one fixed spray jet angle branchpipes PN 16, with a maximum flow rate of
1 000 l/min at a reference pressure of 6 bar (0,6 MPa). It deals with:
-   safety requirements;
-   performance requirements;
-   test methods;
-   classification and designation;
-   information for use;
-   marking and maintenance.
This part of this European Standard applies to branchpipes as defined in Annex A of EN 15182-1:2007.
NOTE 1   These branchpipes offer no or inadequate protection for firefighters when the spray angle is less than 30 ° and therefore, should not be used in high risk fire fighting situations such as internal attack.
NOTE 2   These branchpipes should not be used when fighting fires in or near electrical installations when the spray angle is less than 30 ° without written authorisation from the manufacturer in the manual. This authorisation from the manufacturer should include safety distances.

Status
Withdrawn
Publication Date
03-Nov-2009
Withdrawal Date
22-Sep-2026
Current Stage
9960 - Withdrawal effective - Withdrawal
Start Date
14-Aug-2019
Completion Date
23-Sep-2026

Buy Documents

Standard

EN 15182-3:2007+A1:2010

English language (8 pages)
Preview
Preview
e-Library read for
1 day

Relations

Effective Date
18-Jan-2023
Effective Date
21-Aug-2019
Effective Date
28-Jan-2026

Buy Documents

Standard

EN 15182-3:2007+A1:2010

English language (8 pages)
Preview
Preview
e-Library read for
1 day

Get Certified

Connect with accredited certification bodies for this standard

CIS Institut d.o.o.

Personal Protective Equipment (PPE) certification body. Notified Body NB-2890 for EU Regulation 2016/425 PPE.

SA Slovenia Verified

Kiwa BDA Testing

Building and construction product certification.

RVA Netherlands Verified

Kmetijski inštitut Slovenije

Agricultural Institute of Slovenia. Soil testing, plant health, agricultural product analysis.

SA Slovenia Verified

Sponsored listings

Frequently Asked Questions

EN 15182-3:2007+A1:2009 is a standard published by the European Committee for Standardization (CEN). Its full title is "Hand-held branchpipes for fire service use - Part 3: Smooth bore jet and/or one fixed spray jet angle branchpipes PN 16". This standard covers: In addition to the requirements given in EN 15182-1, this part of this European Standard applies to hand-held branchpipes with smooth bore jet and/or one fixed spray jet angle branchpipes PN 16, with a maximum flow rate of 1 000 l/min at a reference pressure of 6 bar (0,6 MPa). It deals with: - safety requirements; - performance requirements; - test methods; - classification and designation; - information for use; - marking and maintenance. This part of this European Standard applies to branchpipes as defined in Annex A of EN 15182-1:2007. NOTE 1 These branchpipes offer no or inadequate protection for firefighters when the spray angle is less than 30 ° and therefore, should not be used in high risk fire fighting situations such as internal attack. NOTE 2 These branchpipes should not be used when fighting fires in or near electrical installations when the spray angle is less than 30 ° without written authorisation from the manufacturer in the manual. This authorisation from the manufacturer should include safety distances.

In addition to the requirements given in EN 15182-1, this part of this European Standard applies to hand-held branchpipes with smooth bore jet and/or one fixed spray jet angle branchpipes PN 16, with a maximum flow rate of 1 000 l/min at a reference pressure of 6 bar (0,6 MPa). It deals with: - safety requirements; - performance requirements; - test methods; - classification and designation; - information for use; - marking and maintenance. This part of this European Standard applies to branchpipes as defined in Annex A of EN 15182-1:2007. NOTE 1 These branchpipes offer no or inadequate protection for firefighters when the spray angle is less than 30 ° and therefore, should not be used in high risk fire fighting situations such as internal attack. NOTE 2 These branchpipes should not be used when fighting fires in or near electrical installations when the spray angle is less than 30 ° without written authorisation from the manufacturer in the manual. This authorisation from the manufacturer should include safety distances.

EN 15182-3:2007+A1:2009 is classified under the following ICS (International Classification for Standards) categories: 13.220.10 - Fire-fighting. The ICS classification helps identify the subject area and facilitates finding related standards.

EN 15182-3:2007+A1:2009 has the following relationships with other standards: It is inter standard links to EN 15182-3:2007, EN 15182-3:2019, EN 15182-1:2007. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

EN 15182-3:2007+A1:2009 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)


2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Strahlrohre für die Brandbekämpfung - Teil 3: Strahlrohre mit Vollstrahl und/oder einem unveränderlichen Sprühstrahlwinkel PN 16Lances à main destinées aux services d'incendie et de secours - Partie 3: Lances à jet plein et/ou une diffusion à angle fixe PN 16Hand-held branchpipes for fire service use - Part 3: Smooth bore jet and/or one fixed spray jet angle branchpipes PN 1613.220.10Gašenje požaraFire-fightingICS:Ta slovenski standard je istoveten z:EN 15182-3:2007+A1:2009SIST EN 15182-3:2007+A1:2010en,fr,de01-januar-2010SIST EN 15182-3:2007+A1:2010SLOVENSKI
STANDARD
EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM
EN 15182-3:2007+A1
November 2009 ICS 13.220.10 Supersedes EN 15182-3:2007English Version
Hand-held branchpipes for fire service use - Part 3: Smooth borejet and/or one fixed spray jet angle branchpipes PN 16
Lances à main destinées aux services d'incendie et de secours - Partie 3: Lances à jet plein et/ou une diffusion à angle fixe PN 16
Strahlrohre für die Brandbekämpfung - Teil 3: Strahlrohre mit Vollstrahl und/oder einem unveränderlichem Sprühstrahlwinkel PN 16 This European Standard was approved by CEN on 23 December 2006
and includes Amendment 1 approved by CEN on 29 September 2009.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN Management Centre or to any CEN member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN Management Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION EUROPÄISCHES KOMITEE FÜR NORMUNG
Management Centre:
Avenue Marnix 17,
B-1000 Brussels © 2009 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 15182-3:2007+A1:2009: ESIST EN 15182-3:2007+A1:2010
...