General Information

Abstract

This European Standard specifies the characteristics of UV laser printable, tin plated copper conductor, electrical cables Crosslinked Ethylene Tetra Fluoro Ethylene co-polymer (XLETFE) family for use in the on-board electrical systems of aircraft at operating temperatures between –65 ºC and 135 ºC, operating at voltages not exceeding 600 V r.m.s and frequencies not exceeding 2 000 Hz. These cables are suitable for airframe use without additional protection. In case of conflict between this European Standard and other referenced documents the requirements of this European Standard should take precedence.

Status
Withdrawn
Publication Date
07-Feb-2012
Withdrawal Date
22-Sep-2026
Technical Committee
ASD-STAN - Aerospace
Drafting Committee
ASD-STAN/D 2 - Electrical
Current Stage
9960 - Withdrawal effective - Withdrawal
Start Date
28-Nov-2018
Completion Date
23-Sep-2026

Buy Documents

Relations

Effective Date
08-Jun-2022
Effective Date
28-Jan-2026
Effective Date
28-Jan-2026
Effective Date
28-Jan-2026
Effective Date
28-Jan-2026
Effective Date
28-Jan-2026
Effective Date
28-Jan-2026
Effective Date
28-Jan-2026
Effective Date
28-Jan-2026
Effective Date
28-Jan-2026
Effective Date
28-Jan-2026
Effective Date
28-Jan-2026
Effective Date
28-Jan-2026
Effective Date
28-Jan-2026
Effective Date
28-Jan-2026

Buy Documents

Get Certified

Connect with accredited certification bodies for this standard

BUREAU VERITAS Certification Germany

Bureau Veritas certification in Germany.

DAKKS Germany Verified

Element Materials Technology

Materials testing and product certification.

UKAS United Kingdom Verified

AQMS Ltd.

AQMS provides ISO certification to SMEs across the UK.

UKAS United Kingdom Verified

Sponsored listings

Frequently Asked Questions

EN 4611-004:2012 is a standard published by the European Committee for Standardization (CEN). Its full title is "Aerospace series - Cables, electrical, for general purpose, single and multicore assembly - XLETFE Family - Part 004: Tin plated copper - Operating temperatures, between –65 °C and 135 °C - Dual extruded wall for open applications - UV laser printable - Product standard". This standard covers: This European Standard specifies the characteristics of UV laser printable, tin plated copper conductor, electrical cables Crosslinked Ethylene Tetra Fluoro Ethylene co-polymer (XLETFE) family for use in the on-board electrical systems of aircraft at operating temperatures between –65 ºC and 135 ºC, operating at voltages not exceeding 600 V r.m.s and frequencies not exceeding 2 000 Hz. These cables are suitable for airframe use without additional protection. In case of conflict between this European Standard and other referenced documents the requirements of this European Standard should take precedence.

This European Standard specifies the characteristics of UV laser printable, tin plated copper conductor, electrical cables Crosslinked Ethylene Tetra Fluoro Ethylene co-polymer (XLETFE) family for use in the on-board electrical systems of aircraft at operating temperatures between –65 ºC and 135 ºC, operating at voltages not exceeding 600 V r.m.s and frequencies not exceeding 2 000 Hz. These cables are suitable for airframe use without additional protection. In case of conflict between this European Standard and other referenced documents the requirements of this European Standard should take precedence.

EN 4611-004:2012 is classified under the following ICS (International Classification for Standards) categories: 49.060 - Aerospace electric equipment and systems. The ICS classification helps identify the subject area and facilitates finding related standards.

EN 4611-004:2012 has the following relationships with other standards: It is inter standard links to EN 4611-004:2018, EN 3475-408:2025, EN 3475-418:2019, EN 3475-508:2007, EN 3475-411:2018, EN 3475-404:2025, EN 3475-403:2002, EN 3475-811:2009, EN 3475-306:2005, EN 3475-505:2023, EN 3475-407:2009, EN 3475-406:2002, EN 3475-203:2006, EN 3475-801:2002, EN 3475-808:2002. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

EN 4611-004:2012 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)


2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.DVHUVNHJDLuft- und Raumfahrt - Ein- und mehradrige elektrische Leitungen für allgemeine Verwendung - XLETFE Familie - Teil 004: Kupfer verzinnt - Betriebstemperaturen zwischen - 65 °C und 135 °C - Doppelt extrudierte Isolierung für externe Verwendung - UV-Laser bedruckbar - ProduktnormSérie aérospatiale - Câbles, électriques, d'usage général, mono et multiconducteurs - Famille XLETFE - Partie 004 : Cuivre étamé - Températures de fonctionnement comprises entre - 65 °C et 135 °C - Fil double isolé pour applications externes - Marquable au laser UV - Norme de produitAerospace series - Cables, electrical, for general purpose, single and multicore assembly - XLETFE Family - Part 004: Tin plated copper - Operating temperatures, between - 65 °C and 135 °C - Dual extruded wall for open applications - UV laser printable - Product standard49.060Aerospace electric equipment and systemsICS:Ta slovenski standard je istoveten z:EN 4611-004:2012SIST EN 4611-004:2012en,fr,de01-maj-2012SIST EN 4611-004:2012SLOVENSKI
STANDARD
EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM
EN 4611-004
February 2012 ICS 49.060 English Version
Aerospace series - Cables, electrical, for general purpose, single and multicore assembly - XLETFE Family - Part 004: Tin plated copper - Operating temperatures, between -65 °C and 135 °C - Dual extruded wall for open applications - UV laser printable - Product standard
Série aérospatiale - Câbles, électriques, d'usage général, mono et multiconducteurs - Famille XLETFE - Partie 004 : Cuivre étamé - Températures de fonctionnement comprisesentre -65 °C et 135 °C - Fil double isolé pour applications externes - Marquable au laser UV - Norme de produit
Luft- und Raumfahrt - Ein- und mehradrige elektrische Leitungen zur allgemeinen Verwendung - XLETFE-Familie -Teil 004: Kupfer verzinnt, Betriebstemperaturen zwischen -65 °C und 135 °C, doppelt extrudierte Isolierung für offene Anwendungen, UV-Laser bedruckbar - Produktnorm This European Standard was approved by CEN on 17 September 2011.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION EUROPÄISCHES KOMITEE FÜR NORMUNG
Management Centre:
Avenue Marnix 17,
B-1000 Brussels © 2012 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 4611-004:2012: ESIST EN 4611-004:2012
...